LC1K0901M7 - Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 220 to 230VAC coil

Schneider
SKU
SE_LC1K0901M7
Model
LC1K0901M7
SGD $25.76 All prices inclusive of GST

Short description of LC1K0901M7

LC1K0901M7. TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options
The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications.
One of the smallest contactor offerings in the market.
The range delivers strong performance for its compact size and promises seamless integration in all applications.
Widely used for industry, infrastructure and building applications.
Country of Origin
Indonesia

UOM: Piece

In stock
In Stock 16
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V),
and for non-inductive load control applications up to 20A/690V AC-1.
It provides a 220V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by screw clamp terminals.
For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications.
Very compact (45mm width), DIN-rail mounting or screw fixing.
Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
MAIN
RangeTeSys
Product Or Component TypeContactor
Device Short NameLC1K
Device ApplicationControl
Contactor ApplicationMotor control
Resistive load
COMPLEMENTARY
Utilisation CategoryAC-3
AC-3e
AC-1
AC-4
Poles Description3P
Power Pole Contact Composition3 NO
[Ue] Rated Operational VoltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] Rated Operational Current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control Circuit TypeAC at 50/60 Hz
[Uc] Control Circuit Voltage220...230 V AC 50/60 Hz
Motor Power KW2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440/690 V AC 50/60 Hz AC-3
2.2 kW at 220...230 V AC 50/60 Hz AC-3e
4 kW at 380...415 V AC 50/60 Hz AC-3e
4 kW at 440/690 V AC 50/60 Hz AC-3e
2.2 kW at 220...230 V AC 50/60 Hz AC-4
4 kW at 380...415 V AC 50/60 Hz AC-4
4 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary Contact Composition1 NC
[Uimp] Rated Impulse Withstand Voltage8 kV
Overvoltage CategoryIII
[Ith] Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms Rated Making Capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated Breaking Capacity110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[Icw] Rated Short-time Withstand Current90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
20 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
Associated Fuse Rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation Resistance> 10 MOhm for signalling circuit
Inrush Power In VA30 VA (at 20 °C)
Hold-in Power Consumption In VA4.5 VA (at 20 °C)
Heat Dissipation1.3 W
Control Circuit Voltage LimitsOperational: 0.8...1.15 Uc (at <50 °C)
Drop-out: >= 0.20 Uc (at <50 °C)
Connections - TerminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum Operating Rate3600 cyc/h
Auxiliary Contacts Typetype instantaneous 1 NC
Signalling Circuit Frequency<= 400 Hz
Minimum Switching Current5 mA for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Operating Time10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non Overlap Distance0.5 mm
Mechanical Durability10 Mcycles
Electrical Durability1.3 Mcycles 9 A AC-3 at Ue <= 440 V
1.3 Mcycles 9 A AC-3e at Ue <= 440 V
0.16 Mcycles 20 A AC-1 at Ue <= 690 V
0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Mechanical RobustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height58 mm
Width45 mm
Depth57 mm
ENVIRONMENT
StandardsEN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
Product CertificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Protective TreatmentTC conforming to IEC 60068
TC conforming to DIN 50016
Operating Altitude2000 m without derating
Flame RetardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
PACKING UNITS
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.000 cm
Package 1 Width6.200 cm
Package 1 Length6.500 cm
Package 1 Weight177.500 g
Unit Type Of Package 2S02
Number Of Units In Package 250
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.132 kg
Unit Type Of Package 3P06
Number Of Units In Package 3800
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight154.160 kg
CONTRACTUAL WARRANTY