Loading...
*All information are subjected to changes without prior notice.

LC1D32EHE - TeSys D Contactor 3P 32A AC-3 Up To 440V Coil 48-130V AC/DC.

Schneider
SKU
SE_LC1D32EHE
Model
LC1D32EHE
SGD $128.27 All prices inclusive of GST

Short description of LC1D32EHE

LC1D32EHE. Ultra low consumption coil for maximized energy efficiency to meet sustainability needs
Designed to meet the requirements of industrial and HVAC applications
Easier to install and operate with multi-standard screws
With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries
Digital customer experience for technical documents
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3/3e (15kW@400V).
It provides a low consumption 48-130V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals.
For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications.
Compact (45mm width), DIN-rail mounting or screw fixing.
Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
MAIN
RangeTeSys
TeSys Deca
Range Of ProductTeSys Deca
Product Or Component TypeContactor
Device Short NameLC1D
Contactor ApplicationMotor control
Resistive load
Utilisation CategoryAC-1
AC-3
AC-3e
Poles Description3P
[Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz
[Ie] Rated Operational Current32 A (at <60 °C) at <= 440 V AC-3 for power circuit
50 A (at <60 °C) at <= 440 V AC-1 for power circuit
32 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] Control Circuit Voltage48...130 V AC 50/60 Hz
48...130 V DC
COMPLEMENTARY
Motor Power KW7.5 kW at 220...230 V AC 50 Hz (AC-3)
15 kW at 380...400 V AC 50 Hz (AC-3)
15 kW at 415 V AC 50 Hz (AC-3)
15 kW at 440 V AC 50 Hz (AC-3)
18.5 kW at 500 V AC 50 Hz (AC-3)
18.5 kW at 660...690 V AC 50 Hz (AC-3)
7.5 kW at 220...230 V AC 50 Hz (AC-3e)
15 kW at 380...400 V AC 50 Hz (AC-3e)
15 kW at 415 V AC 50 Hz (AC-3e)
15 kW at 440 V AC 50 Hz (AC-3e)
18.5 kW at 500 V AC 50 Hz (AC-3e)
18.5 kW at 660...690 V AC 50 Hz (AC-3e)
Motor Power Hp2 hp at 115 V AC 50/60 Hz for 1 phase motors
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
20 hp at 460/480 V AC 50/60 Hz for 3 phases motors
25 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility CodeLC1D
Pole Contact Composition3 NO
Protective CoverWith
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit
50 A (at 60 °C) for power circuit
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A at 440 V for power circuit conforming to IEC 60947
Rated Breaking Capacity550 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-time Withstand Current100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
60 A 40 °C - 10 min for power circuit
138 A 40 °C - 1 min for power circuit
260 A 40 °C - 10 s for power circuit
430 A 40 °C - 1 s for power circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
63 A gG at <= 690 V coordination type 2 for power circuit
Average Impedance2 mOhm - Ith 50 A 50 Hz for power circuit
Power Dissipation Per Pole2 W AC-3
5 W AC-1
2 W AC-3e
[Ui] Rated Insulation VoltagePower circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Overvoltage CategoryIII
Pollution Degree3
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical Durability15 Mcycles
Electrical Durability2.1 Mcycles 29 A AC-3 at Ue <= 440 V
0.9 Mcycles 50 A AC-1 at Ue <= 440 V
2.1 Mcycles 29 A AC-3e at Ue <= 440 V
Control Circuit TypeAC/DC at 50/60 Hz AC/DC electronic
Coil TechnologyBuilt-in bidirectional peak limiting
Control Circuit Voltage Limits<= 0.1 Uc (-40…70 °C):drop-out AC/DC
0.85...1.1 Uc (-40…60 °C):operational AC/DC
1...1.1 Uc (60…70 °C):operational AC/DC
Inrush Power In VA25 VA 50/60 Hz (at 20 °C)
Inrush Power In W24 W (at 20 °C)
Hold-in Power Consumption In VA1.3 VA 50/60 Hz (at 20 °C)
Hold-in Power Consumption In W0.8 W at 20 °C
Heat Dissipation0.8 W at 50/60 Hz
Operating Time45...55 ms closing
20...90 ms opening
Maximum Operating Rate3600 cyc/h at 60 °C
Connections - TerminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² - cable stiffness: solid
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: solid
Tightening TorqueControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 M4
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 M3.5
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling Circuit Frequency25...400 Hz
Minimum Switching Voltage17 V for signalling circuit
Minimum Switching Current5 mA for signalling circuit
Insulation Resistance> 10 MOhm for signalling circuit
Non-overlap Time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting SupportPlate
Rail
ENVIRONMENT
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC 60335-1
Product CertificationsCCC
CSA
EAC
UL
KC
DNV-GL
LROS (Lloyds register of shipping)
UKCA
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Climatic Withstandconforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device-40…60 °C
60…70 °C with derating
Operating Altitude0...3000 m
Fire Resistance850 °C conforming to IEC 60695-2-1
Flame RetardanceV1 conforming to UL 94
Mechanical RobustnessVibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Height85 mm
Width45 mm
Depth92 mm
Net Weight0.438 kg
PACKING UNITS
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.3 cm
Package 1 Width9.4 cm
Package 1 Length12.0 cm
Package 1 Weight458.0 g
Unit Type Of Package 2S02
Number Of Units In Package 215
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.164 kg
CONTRACTUAL WARRANTY
Warranty18 months
Write Your Own Review
You're reviewing:LC1D32EHE - TeSys D Contactor 3P 32A AC-3 Up To 440V Coil 48-130V AC/DC.
Your Rating