K30H004UP - Harmony K1, K2, Cam Changeover Switch, 4 Poles, with Off Position, 60° Switching Angle, 32 A, Multi-fixing.
Schneider
SKU
SE_K30H004UP
Model
K30H004UP
SGD $182.80 All prices inclusive of GST
Short description of K30H004UP
K30H004UP. Ø 16-22 mm rotary cam switches
Country of Origin
Austria
range of product : Harmony K
-  product or component type : Complete cam switch
-  component name : K30
-  [Ith] conventional free air thermal current : 32 A
-  mounting location : Front
-  fixing mode : 4 holes
-  cam switch head type : With front plate 64 x 64 mm
-  type of operator : Black handle
-  rotary handle padlocking : Without
-  presentation of legend : With metallic legend, 1
-  0
-  2 black marking
-  cam switch function : Changeover switch
-  return : Without
-  off position : With Off position
-  poles description : 4P
-  switching positions : Left :  0°
-  300°Right :  0°
-  60°
-  IP degree of protection : IP40 conforming to IEC 529IP40 conforming to NF C 20-010
-  product or component type : Complete cam switch
-  component name : K30
-  [Ith] conventional free air thermal current : 32 A
-  mounting location : Front
-  fixing mode : 4 holes
-  cam switch head type : With front plate 64 x 64 mm
-  type of operator : Black handle
-  rotary handle padlocking : Without
-  presentation of legend : With metallic legend, 1
-  0
-  2 black marking
-  cam switch function : Changeover switch
-  return : Without
-  off position : With Off position
-  poles description : 4P
-  switching positions : Left :  0°
-  300°Right :  0°
-  60°
-  IP degree of protection : IP40 conforming to IEC 529IP40 conforming to NF C 20-010
MAIN SPECIFICATIONS | |
---|---|
Control Type | 4P |
Product Or Component Type | complete cam switch |
Range Of Product | Harmony K |
Cam Switch Function | changeover switch |
Cam Switch Head Type | with front plate 64 x 64 mm |
Component Name | K30 |
Off Position | with Off position |
Presentation Of Legend | with metallic legend, 1 - 0 - 2 black marking |
Range Name | Harmony K |
Return | without |
Rotary Handle Padlocking | without |
Short-circuit Protection | 50 A cartridge fuse, type gG |
Switching Positions | left: 0° - 300° right: 0° - 60° |
Type Of Operator | black handle |
COMPLEMENTARY | |
CAD Overall Depth | 119 mm |
CAD Overall Height | 64 mm |
CAD Overall Width | 64 mm |
Compatibility Code | K30H |
Contact Operation | slow-break |
Electrical Connection | captive screw clamp terminals flexible, clamping capacity: 2 x 4 mm² captive screw clamp terminals solid, clamping capacity: 2 x 6 mm² |
Fixing Mode | 4 holes |
Mechanical Durability | 300000 cycles |
Mounting Location | front |
Net Weight | 0.485 kg |
Positive Opening | with |
Short-circuit Current | 5000 A |
Switching Angle | 60 ° |
Switching Capacity In MA | 11000 mA DC at 120 V 2 contact(s) for inductive load (T = 50 ms) 11000 mA DC at 180 V 3 contact(s) for inductive load (T = 50 ms) 11000 mA DC at 60 V 1 contact(s) for inductive load (T = 50 ms) 1200 mA DC at 220 V 1 contact(s) for resistive load (T = 1 ms) 1200 mA DC at 440 V 2 contact(s) for resistive load (T = 1 ms) 1200 mA DC at 660 V 3 contact(s) for resistive load (T = 1 ms) 16000 mA DC at 140 V 3 contact(s) for inductive load (T = 50 ms) 16000 mA DC at 48 V 1 contact(s) for inductive load (T = 50 ms) 16000 mA DC at 95 V 2 contact(s) for inductive load (T = 50 ms) 23000 mA DC at 120 V 2 contact(s) for resistive load (T = 1 ms) 23000 mA DC at 180 V 3 contact(s) for resistive load (T = 1 ms) 23000 mA DC at 60 V 1 contact(s) for resistive load (T = 1 ms) 25000 mA DC at 30 V 1 contact(s) for inductive load (T = 50 ms) 25000 mA DC at 60 V 2 contact(s) for inductive load (T = 50 ms) 25000 mA DC at 90 V 3 contact(s) for inductive load (T = 50 ms) 3200 mA DC at 110 V 1 contact(s) for inductive load (T = 50 ms) 3200 mA DC at 220 V 2 contact(s) for inductive load (T = 50 ms) 3200 mA DC at 330 V 3 contact(s) for inductive load (T = 50 ms) 32000 mA DC at 140 V 3 contact(s) for resistive load (T = 1 ms) 32000 mA DC at 24 V 1 contact(s) for inductive load (T = 50 ms) 32000 mA DC at 24 V 1 contact(s) for resistive load (T = 1 ms) 32000 mA DC at 48 V 1 contact(s) for resistive load (T = 1 ms) 32000 mA DC at 48 V 2 contact(s) for inductive load (T = 50 ms) 32000 mA DC at 48 V 2 contact(s) for resistive load (T = 1 ms) 32000 mA DC at 70 V 3 contact(s) for inductive load (T = 50 ms) 32000 mA DC at 70 V 3 contact(s) for resistive load (T = 1 ms) 32000 mA DC at 95 V 2 contact(s) for resistive load (T = 1 ms) 400 mA DC at 440 V 1 contact(s) for resistive load (T = 1 ms) 400 mA DC at 660 V 2 contact(s) for resistive load (T = 1 ms) 6500 mA DC at 110 V 1 contact(s) for resistive load (T = 1 ms) 6500 mA DC at 220 V 2 contact(s) for resistive load (T = 1 ms) 6500 mA DC at 330 V 3 contact(s) for resistive load (T = 1 ms) |
Tightening Torque | 1.2 N.m |
[Ith] Conventional Free Air Thermal Current | 32 A |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to EN 947-1 6 kV conforming to IEC 947-1 |
[Ui] Rated Insulation Voltage | 690 V (pollution degree 3) conforming to EN 60947-1 690 V (pollution degree 3) conforming to IEC 60947-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-55 °C |
Ambient Air Temperature For Storage | -40-70 °C |
IP Degree Of Protection | IP40 conforming to IEC 529 IP40 conforming to NF C 20-010 |
Overvoltage Category | class II conforming to IEC 60536 class II conforming to NF C 20-030 |
Product Certifications | cULus 120 V 2 hp 1 phase cULus 240 V 5 hp 1 phase cULus 240 V 5 hp 3 phases cULus 480 V 20 hp 3 phases |
Protective Treatment | TC |
Standards | EN/IEC 60947-3 |
OTHER | |
Poles Description | 4P |
[Us] Rated Supply Voltage | Harmony K |
Write Your Own Review