IMD-IM10 - VIGILOHM IM10 110-415VCA
Schneider
SKU
SE_IMD-IM10
Model
IMD-IM10
SGD $4,572.67 All prices inclusive of GST
Short description of IMD IM10
IMD-IM10. VIGILOHM INSULATION MONITOR IM10
Country of Origin
India
VIGILOHM IM10 110-415VCA.
Label :  Vigilohm
-  range :  Vigilohm
-  range of product :  Vigilohm
-  product name :  Vigilohm IM
-  language :  Chinese,German,Italian,French,Spanish,Portuguese,Russian,English
-  device short name :  IM10
-  product or component type :  insulation monitoring device
-  device application :  standard environment application,marine application
-  application :  medium or low disturbed network
-  earthing system :  IT
-  Range Presentation :  The Vigilohm range of insulation monitoring devices (IMDs) provides you with a simple, reliable insulation monitoring, communication and fault location solution for your IT (ungrounded) networks.
This renewed and simplified offer helps increase personnel and equipment safety and process availability.
-  Range Benefits :  In low voltage electrical distributions, the combined use of an IT network arrangement and Insulation Monitoring Devices : 
-  Increases personnel safety
-  Reduces risk of fire or explosion
-  Increases process uptime
-  Ease maintenance and reduce OPEX
-  Range Application Presentation :  Your solution to make the best of your IT electrical network
-  Industry, including chemical, refinery, and transformation processes, where continuous process is critical
-  Infrastructure like airports, harbors, tunnels, and railways where safety is at stake
-  Healthcare areas like operation theaters and intensive care unit for security of patient and medical staff
-  Marine for safety reasons
-  Power Generation like photovoltaic, wind, hydro and nuclear, to prevent fire
-  Extraction, such as oil &gas and mining, to prevent fire and/or explosion
Label :  Vigilohm
-  range :  Vigilohm
-  range of product :  Vigilohm
-  product name :  Vigilohm IM
-  language :  Chinese,German,Italian,French,Spanish,Portuguese,Russian,English
-  device short name :  IM10
-  product or component type :  insulation monitoring device
-  device application :  standard environment application,marine application
-  application :  medium or low disturbed network
-  earthing system :  IT
-  Range Presentation :  The Vigilohm range of insulation monitoring devices (IMDs) provides you with a simple, reliable insulation monitoring, communication and fault location solution for your IT (ungrounded) networks.
This renewed and simplified offer helps increase personnel and equipment safety and process availability.
-  Range Benefits :  In low voltage electrical distributions, the combined use of an IT network arrangement and Insulation Monitoring Devices : 
-  Increases personnel safety
-  Reduces risk of fire or explosion
-  Increases process uptime
-  Ease maintenance and reduce OPEX
-  Range Application Presentation :  Your solution to make the best of your IT electrical network
-  Industry, including chemical, refinery, and transformation processes, where continuous process is critical
-  Infrastructure like airports, harbors, tunnels, and railways where safety is at stake
-  Healthcare areas like operation theaters and intensive care unit for security of patient and medical staff
-  Marine for safety reasons
-  Power Generation like photovoltaic, wind, hydro and nuclear, to prevent fire
-  Extraction, such as oil &gas and mining, to prevent fire and/or explosion
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 110...415 V AC 45...440 Hz +/- 15 % 125...250 V DC +/- 15 % |
Display Type | digital display |
Product Or Component Type | insulation monitoring device |
Range Of Product | Vigilohm |
Thread Type | 0...5 min for signalling circuit |
Application | medium or low disturbed network |
Communication Port Protocol | - |
Device Short Name | IM10 |
EAN13 | 3606480321672 |
Mounting Support | DIN rail panel |
Range | Vigilohm |
Range Name | Vigilohm |
Signal Contacts Composition | 1 C/O standard or fail-safe |
Signalling Circuit Voltage | 12...24 V - DC at 6 A 250 V - AC at 6 A |
Type Of Measurement | network insulation resistance - measurement range: 0.1 kOhm...10 MOhm |
User Language | Chinese English French German Italian Portuguese Russian Spanish |
COMPLEMENTARY | |
Analogue Output Number | digital display |
Product Name | Vigilohm IM |
Time Delay Range | 0...5 min for signalling circuit |
Compatibility Code | IM10 |
Connections - Terminals | removable screw terminal block0.2-2.5 mm² |
Depth | 59 mm |
Device Application | marine application standard environment application |
Earthing System | IT |
Height | 110 mm |
Insulation Shield | NO |
Local Signalling | green indicator light: satisfactory insulation resistance orange flashing indicator light: transient fault orange indicator light: below fault threshold white indicator light: below prevention threshold |
Market Segment | residential small commercial |
Material | thermoplastic |
Measurement Current | 0-0.4 mA |
Measurement Voltage | 75-75 V |
Mounting Mode | clip-on flush-mounted |
Net Weight | 0.25 kg |
Network Rated Voltage | 0-345 V - DC 0-480 V - AC at 45...440 Hz (device connected to phase) 0-600 V - AC at 45...440 Hz (device connected to neutral) |
Power Consumption In VA | 12 VA |
Relative Impedance | 110 kOhm - AC at 0.1...440 Hz |
Response Time | <= 5 s |
Test Function | manual self test |
Threshold Setting | fault: 0.5...500 kOhm prevent: 1 kOhm...1 MOhm |
Type Of Installation | indoor |
Width | 96 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-55 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Dielectric Strength | 4000 V - AC 5500 V - DC |
Environmental Characteristic | exposure to damp heat in service conforming to IEC 60068-2-56 exposure to damp heat not in service conforming to IEC 60068-2-30 salt mist conforming to IEC 60068-2-52 |
IP Degree Of Protection | front face: IP52 |
Operating Altitude | <= 3000 m |
Overvoltage Category | III |
Pollution Degree | 2 |
Product Certifications | BV CE DNV EAC RMRS |
Standards | IEC 60364-4-41 IEC 61010-1 IEC 61326-2-4 IEC 61557-8 |
OTHER | |
Poles Description | insulation monitoring device |
[Us] Rated Supply Voltage | 110...415 V AC 45...440 Hz +/- 15 % 125...250 V DC +/- 15 % |