GV2P07 - Motor Circuit Breaker, TeSys GV2, 3P, 1.6-2.5 A, Thermal Magnetic, Screw Clamp Terminals
Schneider
SKU
SE_GV2P07
Model
GV2P07
SGD $92.22 All prices inclusive of GST
Short description of GV2P07
GV2P07. MOTOR CIRCUIT BREAKER
Country of Origin
Thailand
TeSys GV2
-  Motor circuit breaker
-  thermal
- magnetic
-  1.6…2.5 A.
Label :  TeSys GV2
-  range of product :  TeSys GV2
-  range :  TeSys
-  trip unit technology :  thermal
- magnetic
-  product name :  TeSys GV2
-  device short name :  GV2P
-  product or component type :  circuit breaker
-  device application :  motor
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  Motor circuit breaker
-  thermal
- magnetic
-  1.6…2.5 A.
Label :  TeSys GV2
-  range of product :  TeSys GV2
-  range :  TeSys
-  trip unit technology :  thermal
- magnetic
-  product name :  TeSys GV2
-  device short name :  GV2P
-  product or component type :  circuit breaker
-  device application :  motor
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Contacts Type And Composition | 2.5 A |
Control Type | rotary knob |
Product Or Component Type | circuit breaker |
Range Of Product | TeSys GV2 |
[Ie] Rated Operational Current | rotary knob |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Device Short Name | GV2P |
EAN13 | 3389110213461 |
Network Type | AC |
Power Dissipation Per Pole | 2.5 W |
Range | TeSys TeSys Deca |
Range Name | TeSys GV2 |
Suitability For Isolation | yes conforming to IEC 60947-1 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | AC-3 conforming to IEC 60947-4-1 category A conforming to IEC 60947-2 |
[Ics] Rated Service Short-circuit Breaking Capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
COMPLEMENTARY | |
Communication Network Type | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Interlocked Device | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Product Name | TeSys Deca TeSys GV2 |
[In] Rated Current | 2.5 A |
Colour | dark grey |
Compatibility Code | GV2P |
Depth | 97 mm |
Device Application | motor |
Direct Connector | without |
Electrical Durability | 100000 cycles for AC-3 at 440 V |
Fixing Mode | 35 mm symmetrical DIN rail: clipped panel: screwed (with 2 x M4 screws) |
Height | 89 mm |
Magnetic Tripping Current | 33.5-33.5 A |
Maximum Operating Rate | 25 cyc/h |
Mechanical Durability | 100000 cycles |
Motor Power KW | 0.75-0.75 kW at 400/415 V AC 50/60 Hz 1.1-1.1 kW at 500 V AC 50/60 Hz 1.5-1.5 kW at 690 V AC 50/60 Hz |
Network Frequency | 50/60 Hz conforming to IEC 60947-4-1 |
Operating Position | any position |
Phase Failure Sensitivity | yes conforming to IEC 60947-4-1 |
Rated Duty | continuous conforming to IEC 60947-4-1 |
Tightening Torque | 1.7 N.m on screw clamp terminals |
Trip Unit Rating | 1.6-2.5 A |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 2.5 A conforming to IEC 60947-4-1 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-60 °C |
Ambient Air Temperature For Storage | -40-80 °C |
Fire Resistance | 960 °C conforming to IEC 60695-2-1 |
IK Degree Of Protection | IK04 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Operating Altitude | 2000 m |
Product Certifications | ATEX BV CCC CSA DNV-GL EAC IECEE CB Scheme LROS (Lloyds register of shipping) RINA UKCA UL |
Protective Treatment | TH |
Standards | CSA C22.2 No 60947-4-1 EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 |
OTHER | |
Poles Description | 3P |
[Us] Rated Supply Voltage | TeSys GV2 |
Write Your Own Review