EZC100H3050 - Circuit Breaker Easypact EZC100H - TMD - 50 A - 3 Poles 3d
Schneider
SKU
SE_EZC100H3050
Model
EZC100H3050
SGD $71.71 All prices inclusive of GST
Short description of EZC100H3050
EZC100H3050. MG EZC100 H 30kA 3P/3T 50A
Country of Origin
Thailand
circuit breaker Easypact EZC100H
-  TMD
-  50 A
-  3 poles 3d.
Label : EasyPact
- range : EasyPact
- network type : AC,DC
- network frequency : 50/60 Hz
- range of product : EasyPact
- breaking capacity code : H
- utilisation category : category A
- product name : EasyPact EZC
- trip unit name : TM
- D
- product or component type : circuit breaker
- trip unit technology : thermal
- magnetic
- protection type : overload protection,short-circuit protection
- device short name : Easypact EZC100H
- circuit breaker name : Easypact EZC100H
- device application : distribution-poles description : 3P
- protected poles description : 3t
- Range Presentation : The EasyPact EZC system is the simple and universal solution to satisfy all low voltage protection needs.
-  Easy to choose
-  Easy to install
-  Easy to use
- Range Benefits : It's so Easy and simple
-  Safety and protection
-  Simplicity
- Range Application Presentation : Protection of any electrical installation not exceeding 50kA/415V breaking capacity in particular for residential, buildings and industries
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  TMD
-  50 A
-  3 poles 3d.
Label : EasyPact
- range : EasyPact
- network type : AC,DC
- network frequency : 50/60 Hz
- range of product : EasyPact
- breaking capacity code : H
- utilisation category : category A
- product name : EasyPact EZC
- trip unit name : TM
- D
- product or component type : circuit breaker
- trip unit technology : thermal
- magnetic
- protection type : overload protection,short-circuit protection
- device short name : Easypact EZC100H
- circuit breaker name : Easypact EZC100H
- device application : distribution-poles description : 3P
- protected poles description : 3t
- Range Presentation : The EasyPact EZC system is the simple and universal solution to satisfy all low voltage protection needs.
-  Easy to choose
-  Easy to install
-  Easy to use
- Range Benefits : It's so Easy and simple
-  Safety and protection
-  Simplicity
- Range Application Presentation : Protection of any electrical installation not exceeding 50kA/415V breaking capacity in particular for residential, buildings and industries
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking Capacity Code | H |
Contacts Type And Composition | 100 A at 40 °C |
Control Type | toggle |
Product Or Component Type | circuit breaker |
Range Of Product | EasyPact |
Trip Unit Name | TM-D |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 250 V DC conforming to IEC 60947-2 550 V AC 50/60 Hz conforming to IEC 60947-2 |
Circuit Breaker Name | Easypact EZC100H |
Device Short Name | Easypact EZC100H |
EAN13 | 3303430301257 |
Mounting Support | backplate |
Network Type | AC DC |
Protected Poles Description | 3t |
Range | EasyPact |
Range Name | EasyPact EZC |
Suitability For Isolation | yes conforming to IEC 60947-2 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | category A |
COMPLEMENTARY | |
Communication Network Type | 250 V DC conforming to IEC 60947-2 550 V AC 50/60 Hz conforming to IEC 60947-2 |
Current Transformer Type | H |
Interlocked Device | 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 |
Product Name | EasyPact EZC |
[Ics] Rated Service Breaking Capacity | 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
[In] Rated Current | 100 A at 40 °C |
Compatibility Code | EZC100 |
Connection Pitch | 25 mm |
Depth | 60 mm |
Device Application | distribution |
Downside Connection | front |
Earth-leakage Protection | without |
Electrical Durability | category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 |
Height | 130 mm |
Local Signalling | positive contact indication |
Market Segment | small commercial |
Mechanical Durability | 8500 cycles |
Mounting Mode | fixed |
Network Frequency | 50/60 Hz |
Neutral Protection Setting | without protection |
Protection Type | overload protection short-circuit protection |
Trip Unit Rating | 50-50 A at 50 °C |
Upside Connection | front |
Width | 75 mm |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -35-85 °C |
IK Degree Of Protection | IK07 conforming to IEC 62262 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Pollution Degree | 3 conforming to IEC 60664-1 3 conforming to IEC 947-1 |
Standards | EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 |
OTHER | |
Earth Leakage Current | TM-D |
Poles Description | 3P |
[Us] Rated Supply Voltage | EasyPact |
Write Your Own Review