C12F44V160B - Circuit Breaker ComPacT NSXm F (36kA At 415VAC), 4 Poles 4d, 160A Rating Micrologic 4.1 Trip Unit, Lugs and Busbar Connectors

Schneider
SKU
SE_C12F44V160B
Model
C12F44V160B
SGD $2,969.29 All prices inclusive of GST

Short description of C12F44V160B

C12F44V160B. NSXm160F 36kA AC 4P 160A 4.1 BUSBAR
Country of Origin
Poland
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 18 To 20 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

MAIN SPECIFICATIONS
Breaking Capacity35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity CodeF 36 kA 415 V AC
Contacts Type And Composition160 A at 40 °C
Control Typetoggle
Product Or Component Typeearth leakage circuit breaker
Range Of ProductComPacT NSXm new generation
Trip Unit NameMicrologic 4.1
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage440 V AC 50/60 Hz
690 V AC 50/60 Hz
Device Short NameNSXm 160F
EAN133606481992833
Mounting Supportbackplate
Network TypeAC
Neutral Positionleft
Protected Poles Description4D
RangeComPacT new generation
Range NameComPacT NSXm (2021)
Suitability For Isolationyes conforming to IEC 60947-2
Trip Unit Protection FunctionsLSoIR
Trip Unit Technologyelectronic
Utilisation Categorycategory A
COMPLEMENTARY
Communication Network Type440 V AC 50/60 Hz
690 V AC 50/60 Hz
Current Transformer TypeF 36 kA 415 V AC
Interlocked Device35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Product NameComPacT NSXm new generation
[Ics] Rated Service Breaking Capacity30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
[In] Rated Current160 A at 40 °C
9 Mm Pitches12 module
Colourgrey (RAL 7016)
Connection Pitch27 mm without spreaders
35 mm with spreaders
Connections - Terminals compression lug/busbar
Depth80 mm
Device Applicationdistribution
protection
Downside Connectionfront
Earth-leakage Sensitivity100 mA for class A
100 mA for class AC
1000 mA for class A
1000 mA for class AC
30 mA for class A
30 mA for class AC
300 mA for class A
300 mA for class AC
3000 mA for class AC
500 mA for class A
500 mA for class AC
5000 mA for class AC
Electrical Durability10000 cycles at 440 V In
10000 cycles at 690 V In/2
20000 cycles at 440 V In/2
5000 cycles at 690 V In
Height144 mm
Instantaneous Pick-up Adjustment Range2000 A
Local Signallingflag (green) for presence of auxiliary contacts
Long Time Delay Adjustment Typefixed
Long Time Pick-up Adjustment Range0.4...1 x In
Long Time Pick-up Adjustment Type Iradjustable 9 settings
Mechanical Durability20000 cycles
Mounting Modefixed
Net Weight1.63 kg
Network Frequency50/60 Hz
Number Of Slots1 slot(s) for alarm switch SD
1 slot(s) for auxiliary switch OF
1 slot(s) for voltage release MN or MX
Power Losses12.21 W
Short-time Delay Adjustment Typefixed
Short-time Pick-up Adjustment Type Isdadjustable 9 settings
Thermal Memory20 minutes before and after tripping
Trip Unit Rating160-160 A at 40 °C
Upside Connectionfront
Width108 mm
[Isd] Short-time Pick-up Adjustment Range1.5...10 x Ir
[IΔn] Residual Earth-leakage Sensitive Adjustment100-100 mA
1-1 A
300-300 mA
30-30 mA
3-3 A
500-500 mA
5-5 A
[tr] Long-time Delay Adjustment Range200-200 s at 1.5 x Ir
5-5 s at 7.2 x Ir
8-8 s at 6 x Ir
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ui] Rated Insulation Voltage500 V
800 V
[Δt] Residual Earth-leakage Time Delay Adjustment0-0 ms
1000-1000 ms
150-150 ms
500-500 ms
60-60 ms
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
IK Degree Of ProtectionIK07 conforming to IEC 62262
IP Degree Of ProtectionIP40
Operating Altitude2000 m without derating
5000 m with derating
Pollution Degree3 conforming to IEC 60664-1
StandardsEN/IEC 60947
OTHER
Earth Leakage CurrentMicrologic 4.1
Poles Description4P
[Us] Rated Supply VoltageComPacT NSXm new generation
Write Your Own Review
You're reviewing:C12F44V160B - Circuit Breaker ComPacT NSXm F (36kA At 415VAC), 4 Poles 4d, 160A Rating Micrologic 4.1 Trip Unit, Lugs and Busbar Connectors
Your Rating