ATV950U07N4E - Variable Speed Drive, Altivar Process ATV900, ATV950, 0,75 KW, 400/480 V, W Braking Unit/Switch, IP55.
Schneider
SKU
SE_ATV950U07N4E
Model
ATV950U07N4E
SGD $2,074.49 All prices inclusive of GST
Short description of ATV950U07N4E
ATV950U07N4E. Variable speed drive for demanding applications from 0.75kW to 800kW
Country of Origin
China
range of product : Altivar Process ATV900
-  product or component type : Variable speed drive
-  device application : Industrial application
-  device short name : ATV950
-  variant : With braking chopperWith load break switch
-  product destination : Asynchronous motorsSynchronous motors
-  EMC filter : Integrated with 50 m conforming to EN/IEC 61800-3 category C2Integrated with 150 m conforming to EN/IEC 61800-3 category C3
-  IP degree of protection : IP55 conforming to IEC 61800-5-1IP55 conforming to IEC 60529
-  type of cooling : Forced convection
-  supply frequency : 50...60 Hz +/- 5 %
-  network number of phases : 3 phases
-  [Us] rated supply voltage : 380...480 V
-  15...10 %
-  motor power kW : 0.75 kW (normal duty)0.37 kW (heavy duty)
-  motor power hp : 1 hp normal duty0.5 hp heavy duty
-  line current : 1.5 A at 380 V (normal duty)1.3 A at 480 V (normal duty)0.9 A at 380 V (heavy duty)0.8 A at 480 V (heavy duty)
-  prospective line Isc : 50 kA
-  apparent power : 1.1 kVA at 480 V (normal duty)0.7 kVA at 480 V (heavy duty)
-  continuous output current : 2.2 A at 4 kHz for normal duty1.5 A at 4 kHz for heavy duty
-  maximum transient current : 2.6 A during 60 s (normal duty)2.3 A during 60 s (heavy duty)
-  asynchronous motor control profile : Constant torque standardVariable torque standardOptimized torque mode
-  synchronous motor control profile : Permanent magnet motorSynchronous reluctance motor
-  speed drive output frequency : 0.1…599 Hz
-  nominal switching frequency : 4 kHz
-  switching frequency : 2...16 kHz adjustable4...16 kHz with derating factor
-  safety function : STO (safe torque off) SIL 3
-  number of preset speeds : 16 preset speeds
-  communication port protocol : Modbus TCPModbus serialEtherNet/IP
-  option module : Slot A :  communication module for Profibus DP V1Slot A :  communication module for ProfinetSlot A :  communication module for DeviceNetSlot A :  communication module for EtherCATSlot A :  communication module for CANopen daisy chain RJ45Slot A :  communication module for CANopen SUB
- D 9Slot A :  communication module for CANopen screw terminalsSlot A/slot B/slot C :  digital and analog I/O extension moduleSlot A/slot B/slot C :  output relay extension moduleSlot B :  5/12 V digital encoder interface moduleSlot B :  analog encoder interface moduleSlot B :  resolver encoder interface module communication module for Ethernet Powerlink
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  product or component type : Variable speed drive
-  device application : Industrial application
-  device short name : ATV950
-  variant : With braking chopperWith load break switch
-  product destination : Asynchronous motorsSynchronous motors
-  EMC filter : Integrated with 50 m conforming to EN/IEC 61800-3 category C2Integrated with 150 m conforming to EN/IEC 61800-3 category C3
-  IP degree of protection : IP55 conforming to IEC 61800-5-1IP55 conforming to IEC 60529
-  type of cooling : Forced convection
-  supply frequency : 50...60 Hz +/- 5 %
-  network number of phases : 3 phases
-  [Us] rated supply voltage : 380...480 V
-  15...10 %
-  motor power kW : 0.75 kW (normal duty)0.37 kW (heavy duty)
-  motor power hp : 1 hp normal duty0.5 hp heavy duty
-  line current : 1.5 A at 380 V (normal duty)1.3 A at 480 V (normal duty)0.9 A at 380 V (heavy duty)0.8 A at 480 V (heavy duty)
-  prospective line Isc : 50 kA
-  apparent power : 1.1 kVA at 480 V (normal duty)0.7 kVA at 480 V (heavy duty)
-  continuous output current : 2.2 A at 4 kHz for normal duty1.5 A at 4 kHz for heavy duty
-  maximum transient current : 2.6 A during 60 s (normal duty)2.3 A during 60 s (heavy duty)
-  asynchronous motor control profile : Constant torque standardVariable torque standardOptimized torque mode
-  synchronous motor control profile : Permanent magnet motorSynchronous reluctance motor
-  speed drive output frequency : 0.1…599 Hz
-  nominal switching frequency : 4 kHz
-  switching frequency : 2...16 kHz adjustable4...16 kHz with derating factor
-  safety function : STO (safe torque off) SIL 3
-  number of preset speeds : 16 preset speeds
-  communication port protocol : Modbus TCPModbus serialEtherNet/IP
-  option module : Slot A :  communication module for Profibus DP V1Slot A :  communication module for ProfinetSlot A :  communication module for DeviceNetSlot A :  communication module for EtherCATSlot A :  communication module for CANopen daisy chain RJ45Slot A :  communication module for CANopen SUB
- D 9Slot A :  communication module for CANopen screw terminalsSlot A/slot B/slot C :  digital and analog I/O extension moduleSlot A/slot B/slot C :  output relay extension moduleSlot B :  5/12 V digital encoder interface moduleSlot B :  analog encoder interface moduleSlot B :  resolver encoder interface module communication module for Ethernet Powerlink
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analog/digital Conversion | software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
Analogue Input Number | 3 |
Analogue Input Range | 3 |
Discrete Input Number | 10 |
Discrete Output Type | logic output DQ- 0-1 kHz <= 30 V DC 100 mA logic output DQ+ 0-1 kHz <= 30 V DC 100 mA programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA |
Product Or Component Type | variable speed drive |
Range Of Product | Altivar Process ATV900 |
Communication Port Protocol | EtherNet/IP Modbus serial Modbus TCP |
Method Of Access | slave Modbus TCP |
Network Number Of Phases | 3 phases |
Range Name | Altivar Process ATV900 |
COMPLEMENTARY | |
Analogue Input Type | AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits |
Analogue Output Number | 2 |
Analogue Output Type | software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
Discrete Output Number | 2 |
Output Voltage | AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits |
Port Ethernet | 2 |
[Ics] Rated Service Breaking Capacity | logic output DQ- 0-1 kHz <= 30 V DC 100 mA logic output DQ+ 0-1 kHz <= 30 V DC 100 mA programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA |
Acceleration And Deceleration Ramps | linear adjustable separately from 0.01...9999 s |
Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
Apparent Power | 0.7 kVA at 480 V (heavy duty) 1.1 kVA at 480 V (normal duty) |
Asynchronous Motor Control Profile | constant torque standard optimized torque mode variable torque standard |
Braking To Standstill | by DC injection |
Continuous Output Current | 1.5 A at 4 kHz for heavy duty 2.2 A at 4 kHz for normal duty |
Data Format | 8 bits, configurable odd, even or no parity for Modbus serial |
Depth | 300 mm |
Device Application | industrial application |
Discrete Input Logic | 16 preset speeds negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1) positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1) positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1) positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
Discrete Input Type | DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI7, DI8 programmable as pulse input: 0-30 kHz, 24 V DC (<= 30 V) STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
Electrical Connection | control: screw terminal 0.5...1.5 mm² DC bus: screw terminal 2.5...6 mm² line side: screw terminal 4...6 mm² motor: screw terminal 4...6 mm² |
Exchange Mode | half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Height | 678 mm |
Input Compatibility | DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Insulation Resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Isolation | between power and control terminals |
Linearity Error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
Local Signalling | communication module status: 2 LED (dual colour) embedded communication status: 5 LED (dual colour) local diagnostic: 3 LED (mono/dual colour) presence of voltage: 1 LED (red) |
Marking | CE |
Maximum Switching Current | relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC relay output R1 on resistive load, cos phi = 1 : 3 A at 250 V AC relay output R1 on resistive load, cos phi = 1 : 3 A at 30 V DC relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 250 V AC relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 30 V DC |
Minimum Switching Current | relay output R1, R2, R3: 5 mA at 24 V DC |
Motor Slip Compensation | adjustable automatic whatever the load can be suppressed not available in permanent magnet motor law |
Mounting Mode | wall mount |
Net Weight | 10.5 kg |
Nominal Switching Frequency | 4 kHz |
Number Of Addresses | 1-247 for Modbus serial |
Operating Position | vertical +/- 10 degree |
Option Card | communication module for Ethernet Powerlink slot A/slot B/slot C: digital and analog I/O extension module slot A/slot B/slot C: output relay extension module slot A: communication module for CANopen daisy chain RJ45 slot A: communication module for CANopen screw terminals slot A: communication module for CANopen SUB-D 9 slot A: communication module for DeviceNet slot A: communication module for EtherCAT slot A: communication module for Profibus DP V1 slot A: communication module for Profinet slot B: 5/12 V digital encoder interface module slot B: analog encoder interface module slot B: resolver encoder interface module |
Product Destination | asynchronous motors synchronous motors |
Prospective Line Isc | 50 kA |
Protection Type | break on the control circuit: drive line supply overvoltage: drive line supply phase loss: drive line supply undervoltage: drive motor phase break: drive motor phase break: motor overcurrent between output phases and earth: drive overheating: drive overload of output voltage: drive overspeed: drive overvoltages on the DC bus: drive safe torque off: drive safe torque off: motor short-circuit protection: drive thermal protection: drive thermal protection: motor |
Refresh Time | relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Relay Output Number | 3 |
Relay Output Type | configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
Sampling Duration | 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input 2 ms +/- 0.5 ms (DI1...DI8) - discrete input 5 ms +/- 1 ms (AQ1, AQ2) - analog output 5 ms +/- 1 ms (DI7, DI8) - pulse input |
Supply | external supply for digital inputs: 24 V DC (19-30 V), <1.25 mA, protection type: overload and short-circuit protection internal supply for digital inputs and STO: 24 V DC (21-27 V), <200 mA, protection type: overload and short-circuit protection internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
Switching Frequency | 2...16 kHz adjustable 4...16 kHz with derating factor |
Synchronous Motor Control Profile | permanent magnet motor synchronous reluctance motor |
Transmission Rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
Type Of Polarization | no impedance for Modbus serial |
Width | 264 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -15-40 °C (without derating) 40-50 °C (with derating factor) |
Ambient Air Temperature For Storage | -40-70 °C |
Electromagnetic Compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Environmental Characteristic | chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
IP Degree Of Protection | IP55 |
Maximum THDI | <48 % full load conforming to IEC 61000-3-12 |
Noise Level | 52 dB conforming to 86/188/EEC |
Operating Altitude | <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m |
Product Certifications | TÜV |
Relative Humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
Shock Resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration Resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6 |
OTHER | |
Poles Description | variable speed drive |
[Us] Rated Supply Voltage | 380...480 V - 15...10 % |
Write Your Own Review