ATS22D47Q - Soft Starter-ATS22-control 220V-power 230V(11kW)/400...440V(22kW)
Schneider
SKU
SE_ATS22D47Q
Model
ATS22D47Q
SGD $1,098.41 All prices inclusive of GST
Short description of ATS22D47Q
ATS22D47Q. SOFT STARTER 47A 440V 230V CTRL
Country of Origin
Indonesia
soft starter
- ATS22-control 220V
- power 230V(11kW)/400...440V(22kW).
Label :  Altistart 22
-  range of product :  Altistart 22
-  motor power kW :  11 kW 230 V, 22 kW 400 V, 22 kW 440 V
-  factory setting current :  42 A
-  power dissipation in W :  48 W for standard applications
-  utilisation category :  AC
- 53A
-  product or component type :  soft starter
-  type of start :  start with torque control (current limited to 3.5 In)
-  product destination :  asynchronous motors
-  IcL starter rating :  47 Afor connection in the motor supply line for standard applications
-  product specific application :  pumps and fans
-  IP degree of protection :  N/A
-  component name :  ATS22
-  network number of phases :  3 phases
-  [Us] rated supply voltage :  230...440 V
-  15...10 %
-  Range Presentation :  Soft start/soft stop unit for infrastructure and industrial applications
Altistart 22 soft start/soft stop unit for 3-phase asynchronous motorsSimplifies installation and operation
-  Saves time on wiring (6 terminals instead of 12)
-  Optimises the size of your enclosures (very compact product)
-  Keeps temperature rises to a minimum (low heat dissipation)
-  Reduces the number of components to manage (multifunction product) Protects your installations
-  Minimises jolts and shocks
-  Reduces mechanical stresses on the machines
-  Increases the service life of your installations
-  Prevents installation failure by detecting and signalling faults such as a blocked motor, underload or incorrect earthing of one of the 3 phases A safe product with numerous integrated functions
-  Bypass and safety functions
-  Protection devices for monitoring the motor, the electrical installation and the starter itself
-  Simple setup and operation with : 
-  4 light emitting diodes (LEDs)
-  4 navigation keys
-  4-digit display
-  SoMove software for configuring on PC and transferring the configuration via Bluetooth® or using a cable
-  Coated cards as standard for enhanced resistance to harsh environments
-  Range Benefits :  Bypass the stresses and let your applications take the strain
-  Integrates bypass and safety functions
-  Reduces your operating costs
-  Simplifies wiring
-  Protects your electrical installation
-  Saves space with a fully equipped product
-  Range Application Presentation : 
-  Pumps
-  Fans
-  Compressors
- ATS22-control 220V
- power 230V(11kW)/400...440V(22kW).
Label :  Altistart 22
-  range of product :  Altistart 22
-  motor power kW :  11 kW 230 V, 22 kW 400 V, 22 kW 440 V
-  factory setting current :  42 A
-  power dissipation in W :  48 W for standard applications
-  utilisation category :  AC
- 53A
-  product or component type :  soft starter
-  type of start :  start with torque control (current limited to 3.5 In)
-  product destination :  asynchronous motors
-  IcL starter rating :  47 Afor connection in the motor supply line for standard applications
-  product specific application :  pumps and fans
-  IP degree of protection :  N/A
-  component name :  ATS22
-  network number of phases :  3 phases
-  [Us] rated supply voltage :  230...440 V
-  15...10 %
-  Range Presentation :  Soft start/soft stop unit for infrastructure and industrial applications
Altistart 22 soft start/soft stop unit for 3-phase asynchronous motorsSimplifies installation and operation
-  Saves time on wiring (6 terminals instead of 12)
-  Optimises the size of your enclosures (very compact product)
-  Keeps temperature rises to a minimum (low heat dissipation)
-  Reduces the number of components to manage (multifunction product) Protects your installations
-  Minimises jolts and shocks
-  Reduces mechanical stresses on the machines
-  Increases the service life of your installations
-  Prevents installation failure by detecting and signalling faults such as a blocked motor, underload or incorrect earthing of one of the 3 phases A safe product with numerous integrated functions
-  Bypass and safety functions
-  Protection devices for monitoring the motor, the electrical installation and the starter itself
-  Simple setup and operation with : 
-  4 light emitting diodes (LEDs)
-  4 navigation keys
-  4-digit display
-  SoMove software for configuring on PC and transferring the configuration via Bluetooth® or using a cable
-  Coated cards as standard for enhanced resistance to harsh environments
-  Range Benefits :  Bypass the stresses and let your applications take the strain
-  Integrates bypass and safety functions
-  Reduces your operating costs
-  Simplifies wiring
-  Protects your electrical installation
-  Saves space with a fully equipped product
-  Range Application Presentation : 
-  Pumps
-  Fans
-  Compressors
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 230...440 V - 15...10 % |
Discrete Input Number | 3 |
Discrete Output Type | relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
Display Type | RS485 multidrop |
Measurement Accuracy | 1 RJ45 |
Physical Interface | RS485 multidrop |
Product Or Component Type | soft starter |
Range Of Product | Altistart 22 |
[Uc] Control Circuit Voltage | 230 V - 15...10 % 50/60 Hz |
Communication Port Protocol | Modbus |
Component Name | ATS22 |
Discrete Input Voltage | 24 V <= 30 V |
EAN13 | 3606480167201 |
Factory Setting Current | 42 A |
Function Available | internal bypass |
IcL Starter Rating | 47 A for connection in the motor supply line for standard applications |
Network Number Of Phases | 3 phases |
Product Specific Application | pumps and fans |
Range Name | Altistart 22 |
Type Of Start | start with torque control (current limited to 3.5 In) |
Utilisation Category | AC-53A |
COMPLEMENTARY | |
Analogue Input Type | 3 |
Connector Type | 1 RJ45 |
Discrete Output Number | 2 |
Port Ethernet | 2 |
[Ics] Rated Service Breaking Capacity | relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
Assembly Style | with heat sink |
Communication Data Link | serial |
Control Circuit Consumption | 20 W |
Depth | 169 mm |
Device Connection | in the motor supply line to the motor delta terminals |
Discrete Input Logic | positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
Discrete Input Type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm |
Height | 265 mm |
Installed Device | 31 |
Marking | CE |
Maximum Switching Current | 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs |
Minimum Switching Current | 100 mA at 12 V DC (relay outputs) |
Motor Power KW | 11 kW 230 V 22 kW 400 V 22 kW 440 V |
Motor Starter Type | soft starter |
Net Weight | 7 kg |
Network Frequency | 45...66 Hz |
Operating Position | vertical +/- 10 degree |
Output Current | 0.4...1 Icl adjustable |
Power Dissipation In W | 48 W for standard applications |
Power Range | 15-25 kW at 380-440 V 3 phases 7-11 kW at 200-240 V 3 phases |
Product Destination | asynchronous motors |
Protection Type | phase failure: line thermal protection: motor thermal protection: starter |
PTC Probe Input | 750 Ohm |
Supply Frequency | 50...60 Hz - 10...10 % |
Supply Voltage Limits | 195-484 V |
Transmission Rate | 4800, 9600 or 19200 bps |
Type Of Cooling | forced convection |
Width | 130 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -10-40 °C (without derating) 40-60 °C (with current derating 2.2 % per °C) |
Ambient Air Temperature For Storage | -25-70 °C |
Electromagnetic Compatibility | conducted and radiated emissions level A conforming to IEC 60947-4-2 damped oscillating waves level 3 conforming to IEC 61000-4-12 electrostatic discharge level 3 conforming to IEC 61000-4-2 immunity to electrical transients level 4 conforming to IEC 61000-4-4 immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 voltage/current impulse level 3 conforming to IEC 61000-4-5 |
IP Degree Of Protection | IP20 |
Noise Level | 45 dB |
Operating Altitude | <= 1000 m without derating > 1000...< 2000 m with current derating of 2.2 % per additional 100 m |
Pollution Degree | level 2 conforming to IEC 60664-1 |
Product Certifications | CCC CSA C-Tick GOST UL |
Relative Humidity | 0-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Shock Resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Standards | EN/IEC 60947-4-2 |
Vibration Resistance | 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2-13 Hz) conforming to EN/IEC 60068-2-6 |
OTHER | |
Poles Description | soft starter |
[Us] Rated Supply Voltage | 230...440 V - 15...10 % |
Write Your Own Review