A9MEM3350 - IEM3350 Energy Meter - 125 A - Modbus
Schneider
SKU
SE_A9MEM3350
Model
A9MEM3350
SGD $754.48 All prices inclusive of GST
Short description of A9MEM3350
A9MEM3350. Triphase kWh meter 125A Modbus
Country of Origin
China
iEM3350 energy meter
-  125 A
-  Modbus.
Label :  Acti 9 iEM3000 series
-  range :  Acti 9
-  product name :  Acti 9 iEM3000
-  device short name :  iEM3350
-  product or component type :  energy meter
-  market segment :  N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  Range Presentation :  The Acti 9 iEM3000 series energy meters is a cost-attractive, feature
- rich energy metering offer for DIN rail, modular enclosures. With native Modbus, BACnet, M
- bus and LON protocol support, you can easily integrate these meters into commercial and non
- critical buildings to add simple energy management applications to virtually any BMS, AMR or EMS system.
-  Range Benefits :  Optimize your energy consumption & enable energy efficiency practices
-  Collect and analyze energy consumption data from each area for each type of load or circuit
-  Gain an accurate understanding of business expenses by allocating the energy
- related costs
-  Use information to implement actions designed to reduce energy consumption Monitor the energy consumption of your tenants or customers and establish accurate invoices
-  Drive energy
- efficient behavior
-  Range Application Presentation :  Cost management applications
-  Bill checking to verify that you are only charged for the energy you use
-  Sub billing individual tenants for their energy consumption, including WAGES
-  Aggregation of energy consumption, including WAGES, and allocating costs per area, per usage, per shift, or per time within the same facility Network management applications
-  Basic metering of electrical parameters to better understand the behavior of your electrical distribution system Market segments
-  Buildings
-  Industry
-  Data centers & networks
-  Infrastructure (airports, road tunnels, telecom)
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  125 A
-  Modbus.
Label :  Acti 9 iEM3000 series
-  range :  Acti 9
-  product name :  Acti 9 iEM3000
-  device short name :  iEM3350
-  product or component type :  energy meter
-  market segment :  N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  Range Presentation :  The Acti 9 iEM3000 series energy meters is a cost-attractive, feature
- rich energy metering offer for DIN rail, modular enclosures. With native Modbus, BACnet, M
- bus and LON protocol support, you can easily integrate these meters into commercial and non
- critical buildings to add simple energy management applications to virtually any BMS, AMR or EMS system.
-  Range Benefits :  Optimize your energy consumption & enable energy efficiency practices
-  Collect and analyze energy consumption data from each area for each type of load or circuit
-  Gain an accurate understanding of business expenses by allocating the energy
- related costs
-  Use information to implement actions designed to reduce energy consumption Monitor the energy consumption of your tenants or customers and establish accurate invoices
-  Drive energy
- efficient behavior
-  Range Application Presentation :  Cost management applications
-  Bill checking to verify that you are only charged for the energy you use
-  Sub billing individual tenants for their energy consumption, including WAGES
-  Aggregation of energy consumption, including WAGES, and allocating costs per area, per usage, per shift, or per time within the same facility Network management applications
-  Basic metering of electrical parameters to better understand the behavior of your electrical distribution system Market segments
-  Buildings
-  Industry
-  Data centers & networks
-  Infrastructure (airports, road tunnels, telecom)
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Contacts Type And Composition | 125 A |
Control Type | 1P + N 3P 3P + N |
Display Type | LCD display |
Product Or Component Type | energy meter |
Communication Port Protocol | Modbus RTU at 9.6, 19.2 and 38.4 kbauds even/odd or none, insulation 4000 V |
Device Short Name | iEM3350 |
EAN13 | 3606480696411 |
Maximum Value Measured | 99999999.9 kWh |
Mounting Support | DIN rail |
Range | Acti 9 |
Range Name | iEM3000 series |
Type Of Measurement | active energy active power current voltage |
COMPLEMENTARY | |
Analogue Input Type | direct input |
Analogue Output Number | LCD display |
Output Voltage | direct input |
Product Name | Acti 9 iEM3000 |
[In] Rated Current | 125 A |
9 Mm Pitches | 14 |
Accuracy Class | class 1 active energy conforming to IEC 61557-12 class 1 active energy conforming to IEC 62053-21 class B active energy conforming to EN 50470-3 |
Colour | white |
Communication Port Support | screw terminal block: RS485 |
Compatibility Code | iEM3350 |
Connections - Terminals | screw terminals 50-50 mm² cable(s) |
Depth | 69.3 mm |
Device Application | partial meter sub billing |
Height | 103.2 mm |
Local Signalling | green indicator light: power ON yellow flashing LED: accuracy checking yellow indicator light: communications are active on the Modbus port (Modbus) |
Market Segment | buildings large building cost management: billing: main incomer buildings large building cost management: billing: panelboard buildings large building cost management: billing: sub feeder buildings large building cost management: cost allocation: main incomer buildings large building cost management: cost allocation: panelboard buildings large building cost management: cost allocation: sub feeder buildings medium building cost management: billing: main incomer buildings medium building cost management: billing: panelboard buildings medium building cost management: billing: sub feeder buildings medium building cost management: cost allocation: main incomer buildings medium building cost management: cost allocation: panelboard buildings medium building cost management: cost allocation: sub feeder buildings multi-site cost management: billing: main incomer buildings multi-site cost management: billing: panelboard buildings multi-site cost management: billing: sub feeder buildings multi-site cost management: cost allocation: main incomer buildings multi-site cost management: cost allocation: panelboard buildings multi-site cost management: cost allocation: sub feeder buildings small building cost management: billing: main incomer buildings small building cost management: billing: panelboard buildings small building cost management: billing: sub feeder buildings small building cost management: cost allocation: main incomer buildings small building cost management: cost allocation: panelboard buildings small building cost management: cost allocation: sub feeder data center cost management: billing data center cost management: cost allocation healthcare cost management: billing healthcare cost management: cost allocation industry cost management: billing industry cost management: cost allocation |
Measurement Current | 0-125 A |
Mounting Mode | clip-on |
Network Frequency | 50 Hz 60 Hz |
Rated Voltage | 100-277 V 173-480 V |
Sampling Rate | 32 samples/cycle |
Technology Type | electronic |
Width | 126 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-60 °C - IEC |
Ambient Air Temperature For Storage | -40-85 °C |
IP Degree Of Protection | IP20 body: conforming to IEC 60529 IP40 front panel: conforming to IEC 60529 |
Operating Altitude | < 2000 m |
Overvoltage Category | III |
Pollution Degree | 2 |
Product Certifications | CE conforming to EN 61557-12 (power monitor) CE conforming to IEC 61010 (safety) CE conforming to IEC 61326-1 (EMC) cULus conforming to ANSI C12.20 (sub-meter) cULus conforming to UL 61010 (safety) EAC (sub-meter) RCM conforming to NMI M 6-1 (sub-meter) UL |
Relative Humidity | 5-95 % at 50-50 °C |
Standards | IEC 61010 IEC 61036 IEC 61557-12 IEC 62053-21 IEC 62053-23 UL 61010-1 |
OTHER | |
Poles Description | 1P + N 3P 3P + N |
Write Your Own Review