A9KR13240S - Acti 9 ID K - Residual Current Circuit Breaker - 2P - 40A - 30mA - Type AC (MCB Bundle Deal)
Short description of A9KR13240S
Acti 9 K RCCB 2P 40A 30 mA AC
This is a Acti9 ID K biconnect residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, AC type protection class and a 30mA earth leakage sensitivity. This product protects against electrical shock by direct or indirect contact and fire hazards. There is a test button used to check the residual current device is operating correctly. The connection is made downstream by biconnect comb busbar or upstream/downstream by tunnel terminals. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 500A. The (Inc/IΔc) conditional rated short circuit current is 4.5kA. The electrical endurance is up to 4000 cycles. The mechanical endurance is up to 5000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 81mm x (D) 68mm. The weight is 0.18kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 55°C. The storage temperature is from -25°C to 85°C.
-  residual current circuit breaker
-  2P
-  40A
-  30mA
-  type AC.
Label :  Acti 9 iIDK RCCB
-  range of product :  Acti 9
-  [In] rated current :  40 A
-  network type :  AC
-  earth
- leakage sensitivity :  30 mA
-  earth
- leakage protection time delay :  instantaneous
-  earth
- leakage protection class :  type AC
-  range :  Acti 9
-  product name :  Acti 9 ID K
-  quality labels :  SAFETY Mark
-  product or component type :  residual current circuit breaker (RCCB)
-  device short name :  ID K
-  poles description :  2P
-  neutral position :  left
-  Range Presentation :  Residual current circuit-breaker up to 100A
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Contacts Type And Composition | 40 A |
Control Type | toggle |
Product Or Component Type | residual current circuit breaker (RCCB) |
Range Of Product | Acti 9 |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 220...240 V AC 50 Hz |
Device Short Name | ID K |
EAN13 | 3606480983023 |
Earth-leakage Protection Class | type AC |
Earth-leakage Protection Time Delay | instantaneous |
Mounting Support | DIN rail |
Network Type | AC |
Neutral Position | left |
Range | Acti 9 |
Range Name | Acti 9 iIDK RCCB |
COMPLEMENTARY | |
Communication Network Type | 220...240 V AC 50 Hz |
Product Name | Acti9 ID K |
[In] Rated Current | 40 A |
9 Mm Pitches | 4 |
Colour | white |
Comb Busbar And Distribution Block Compatibility | bottom: fork |
Connections - Terminals | biconnect top or bottom 1-25 mm² flexible biconnect top or bottom 1-35 mm² rigid |
Contact Position Indicator | no |
Depth | 68 mm |
Device Location In System | group incomer |
Earth-leakage Sensitivity | 30 mA |
Electrical Durability | AC-1: 4000 cycles |
Height | 81 mm |
Mechanical Durability | 5000 cycles |
Mounting Mode | clip-on |
Net Weight | 0.18 kg |
Network Frequency | 50 Hz |
Rated Breaking And Making Capacity | Idm 500 A Im 500 A |
Rated Conditional Short-circuit Current | gL63: Inc 4.5 kA K60: Inc 6 kA |
Residual Current Tripping Technology | voltage independent |
Targeted Country | Singapore |
Tightening Torque | 3.5-3.5 N.m top or bottom |
Width | 36 mm |
Wire Stripping Length | 14 mm for top or bottom connection |
[Uimp] Rated Impulse Withstand Voltage | 4 kV |
[Ui] Rated Insulation Voltage | 440 V AC 50 Hz |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -5-55 °C |
Ambient Air Temperature For Storage | -25-85 °C |
Electromagnetic Compatibility | 8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1 |
IP Degree Of Protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
Pollution Degree | 2 |
Quality Labels | SAFETY Mark |
Relative Humidity | 95-95 % at 55-55 °C |
Standards | EN/IEC 61008-1 SS 97:part 1 |
Tropicalisation | 2 conforming to IEC 60068-1 |
OTHER | |
Poles Description | 2P |
[Us] Rated Supply Voltage | Acti 9 |