Short description of A9F73106

Acti9 iC60N 1P B 6A MCB

This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 6A rated current and B tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 0.215kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Country of Origin
India
-
+

UOM: Piece

In stock
In Stock 54
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
iC60N
-  miniature circuit breaker
-  1P
-  6A
-  B curve.
Label :  Acti 9 iC60
-  device application :  distribution
-  [In] rated current :  6 A
-  network type :  AC,DC
-  trip unit technology :  thermal
- magnetic
-  curve code :  B
-  breaking capacity code :  N
-  range :  Acti 9
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A
-  utilisation category :  category A conforming to EN 60947-2, category A conforming to IEC 60947-2
-  suitability for isolation :  yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
-  range of product :  iC60
-  standards :  EN 60898-1,EN 60947-2,IEC 60898-1,IEC 60947-2
-  product name :  Acti 9 iC60
-  product or component type :  miniature circuit-breaker
-  device short name :  iC60N
-  poles description :  1P
-  number of protected poles :  1
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Breaking Capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking Capacity CodeN
Contacts Type And Composition6 A
Control Typetoggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductiC60
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage100...133 V AC 50/60 Hz
12...60 V AC 50/60 Hz
12...60 V DC
220...240 V AC 50/60 Hz
230 V AC 50/60 Hz
72 V DC
Curve CodeB
Device Short NameIC60N
EAN133606480079009
Mounting SupportDIN rail
Network TypeAC
DC
Number Of Protected Poles1
RangeActi 9
Range NameActi 9 iC60
Suitability For Isolationyes conforming to EN 60898-1
yes conforming to EN 60947-2
yes conforming to IEC 60898-1
yes conforming to IEC 60947-2
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A conforming to EN 60947-2
category A conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type100...133 V AC 50/60 Hz
12...60 V AC 50/60 Hz
12...60 V DC
220...240 V AC 50/60 Hz
230 V AC 50/60 Hz
72 V DC
Current Transformer TypeN
Interlocked Device10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Product NameActi9 iC60
[Ics] Rated Service Breaking Capacity10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
[In] Rated Current6 A
9 Mm Pitches2
Colourwhite
Comb Busbar And Distribution Block Compatibilitytop or bottom: YES
Compatibility CodeiC60
Connections - Terminalssingle terminal (top or bottom) 1-16 mm² flexible
single terminal (top or bottom) 1-25 mm² rigid
Contact Position Indicatoryes
Depth78.5 mm
Device Applicationdistribution
Earth-leakage Protectionwithout
Electrical Durability10000 cycles
Height85 mm
Limitation Class3 conforming to EN 60898-1
3 conforming to IEC 60898-1
Local Signallingtrip indicator
Magnetic Tripping Limit4 x In +/- 20 %
Mechanical Durability20000 cycles
Mounting Modefixed
Net Weight0.215 kg
Network Frequency50/60 Hz
Tightening Torque2-2 N.m top or bottom
Width18 mm
Wire Stripping Length14 mm for top or bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-35-70 °C
Ambient Air Temperature For Storage-40-85 °C
IP Degree Of ProtectionIP20 conforming to EN 60529
IP20 conforming to IEC 60529
Operating Altitude0...2000 m
Overvoltage CategoryIV
Pollution Degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Relative Humidity95-95 % at 55-55 °C
StandardsEN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Tropicalisation2 conforming to IEC 60068-1
OTHER
Poles Description1P
[Us] Rated Supply VoltageiC60