Loading...

56170 Earth-leakage Relay RH99M with Manual Reset- 0.03..30A

Schneider
SKU
SE_56170
Model
56170
SGD $385.48 All prices inclusive of GST

Short description of 56170

VigiPacT RH99M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 12/24VAC 50/60Hz, or 12/48VDC. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 8 To 10 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Earth
- leakage relay RH99M with manual reset
-  0.03..30 A
-  0..4.5 s
-  24 V.
Label :  Vigirex RH10MP
- RH21MP
- RH99MP
- RH197-RHU
-  range :  Vigirex
-  range of product :  Vigirex
-  device short name :  RH99M
-  product or component type :  residual current protection relay
-  range compatibility :  ,
-  relay application :  residual current protection relay
-  Range Presentation : 
-  Earth leakage protection and/or indication function
-  Supply voltage : up to 525 V AC, 12 to 48 V DC
-  Available in DIN format and flush-mounted (format 72X72)
-  Wide setting and operating range
-  Operation guaranteed in less than 40 ms
-  Reduced tripping tolerance :  between 0.8 and 1xIΔn
-  RMS measurement of earth leakage currents
-  Surge category :  level IV
-  Class 2 device on the front panel
-  Test and reset buttons on the front panel of the device
-  Optional live testing with or without tripping
-  Extended range of compatible sensors up to 3200 A :  A type closed toroids, OA type split toroids and rectangular sensors
-  High electromagnetic immunity (EMC)
-  Compliance with international standards IEC 60947-2 and 5-1 and IEC 60755, IEC 60364, IEC 61000, IEC 60664, CISPR 11 and UL1053
-  Range Benefits :  Monitor and act in greater safetyDesigned to be adapted to all installation types, Vigirex is a comprehensive range of earth leakage protection and indication devices. With Vigirex, all measures are taken for absolute safety, in complete peace of mind.
-  Range Application Presentation :  The Vigirex residual current relays, combined with a toroid, provide protection against earth leakage currents for all LV electrical network types less than 1000 V, regardless of the type of earthing system (IT, TT or TNS). They protect equipment and people against direct and indirect contact, and equipment against fire hazards.
Specific applications : 
-  Air bases (400 Hz)
-  Telephone relays
-  Radio relays
MAIN SPECIFICATIONS
Analogue Input Number12...24 V AC 50/60 Hz 55...120 %
12...48 V DC 55...120 %
Product Or Component Typeresidual current protection relay
Device Short NameRH99M
EAN133303430561705
Earth-leakage Protection Classtype A
Mounting SupportDIN rail
RangeVigiPacT
Range Compatibility A earth leakage current sensor
L earth leakage current sensor
TOA earth leakage current sensor
Range NameVigirex RH10MP, RH21MP, RH99MP, RH197, RHU
Relay Applicationprotection relay
Type Of Measurementearth fault current internal measurement, range: 80...100 %
[Ithe] Conventional Enclosed Thermal Current8 A
COMPLEMENTARY
Time Delay Range0.03-30 A
9 Mm Pitches6
Compatibility CodeRH99M
Connections - Terminalsauxiliary power supply: terminal block cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12
auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² rigid AWG 24...AWG 12
auxiliary power supply: terminal block cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12
fault: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12
fault: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12
fault: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12
relay test and fault reset: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16
relay test and fault reset: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16
relay test and fault reset: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16
sensor: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16
sensor: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16
sensor: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16
voltage presence: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12
voltage presence: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12
voltage presence: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12
Depth74 mm
Earthing SystemIT
TN-S
TT
Height81 mm
Mechanical Robustnessfire resistance conforming to IEC 60695-2-1
IK protection 2 joules: IK07 conforming to EN 50102
vibrations 13.2...100 Hz: 0.7 g
vibrations 2...13.2 Hz: +/- 1 mm
Minimum Load10 mA at 12 V
Monitoringelectronics (continuous)
power supply (continuous)
relay/sensor link (continuous)
Net Weight0.3 kg
Network Rated Voltage1000-1000 V - AC at 400 Hz (maximum)
1000-1000 V - AC at 50/60 Hz (maximum)
Power Consumption In VA4 VA
Resetmanual reset
Residual Earth-leakage Sensitity Adjustment Typeadjustable 9 settings
Residual Earth-leakage Time Delay Adjustment Typeadjustable 9 settings 0-4.5 s for 0.03-30 A
instantaneous for 0.03-0.03 A
Tamperproof Of Settingsprotected by sealable cover
Test Functionlocal
remote test
Tightening Torqueauxiliary power supply: 0.6-0.6 N.m top
fault: 0.6-0.6 N.m bottom
relay test and fault reset: 0.25-0.25 N.m bottom
sensor: 0.25-0.25 N.m top
voltage presence: 0.6-0.6 N.m bottom
Type Of Settingselector
Width54 mm
Wire Stripping Lengthauxiliary power supply: 7 mm for top connection
fault: 8 mm for bottom connection
relay test and fault reset: 5 mm for bottom connection
sensor: 5 mm for top connection
voltage presence: 8 mm for bottom connection
[Uimp] Rated Impulse Withstand Voltage8 kV
ENVIRONMENT
Ambient Air Temperature For Operation-35-70 °C
Ambient Air Temperature For Storage-55-85 °C
Electrical Shock Protection Classclass II
Electromagnetic Compatibilityconducted and radiated emissions: , B, conforming to CISPR 11
conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6
electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2
high-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5
low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4
radiated susceptibility: , 3, conforming to IEC 61000-4-3
IK Degree Of ProtectionIK07 conforming to EN 50102
IP Degree Of ProtectionIP20 on connection terminals: conforming to EN/IEC 60529
IP30 on side parts: conforming to EN/IEC 60529
IP40 on front face: conforming to EN/IEC 60529
Overvoltage CategoryIV
Pollution Degree3 conforming to IEC 60664-1
Relative Humidity95-95 % at 55-55 °C
OTHER
Earth Leakage Current0.03-30 A
Poles Descriptionresidual current protection relay
[Us] Rated Supply Voltage12...24 V AC 50/60 Hz 55...120 %
12...48 V DC 55...120 %
Write Your Own Review
You're reviewing:Earth-leakage Relay RH99M with Manual Reset - 0.03..30 A - 0..4.5 S - 24 V