Loading...

Closed Toroid for Residual Current Protection MA - Ø 120 Mm

Schneider
SKU
SE_50440
Model
50440
SGD $385.48 All prices inclusive of GST

Short description of 50440

CLOSED TO ROID FOR RESIDUAL CURRENT PROT
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Closed toroid for residual current protection MA
-  Ø 120 mm.
Label :  Vigilohm
-  range :  Vigirex
-  device short name :  MA120
-  product or component type :  earth leakage current sensor
-  device application :  equipment monitoring and control
-  range compatibility :  Vigirex RH plug-in relay
-  [Ie] rated operational current :  250 A
-  Range Presentation :  The Vigilohm range of insulation monitoring devices (IMDs) provides you with a simple, reliable insulation monitoring, communication and fault location solution for your IT (ungrounded) networks.
This renewed and simplified offer helps increase personnel and equipment safety and process availability.
-  Range Benefits :  In low voltage electrical distributions, the combined use of an IT network arrangement and Insulation Monitoring Devices : 
-  Increases personnel safety
-  Reduces risk of fire or explosion
-  Increases process uptime
-  Ease maintenance and reduce OPEX
-  Range Application Presentation :  Your solution to make the best of your IT electrical network
-  Industry, including chemical, refinery, and transformation processes, where continuous process is critical
-  Infrastructure like airports, harbors, tunnels, and railways where safety is at stake
-  Healthcare areas like operation theaters and intensive care unit for security of patient and medical staff
-  Marine for safety reasons
-  Power Generation like photovoltaic, wind, hydro and nuclear, to prevent fire
-  Extraction, such as oil &gas and mining, to prevent fire and/or explosion
MAIN SPECIFICATIONS
Diameter120 mm inner:
Product Or Component Typeearth leakage current sensor
[Ie] Rated Operational Current250 A
[Ue] Rated Operational Voltage250 A
Device Short NameMA120
EAN133303430504405
Network TypeAC/DC
RangeVigiPacT
Range Compatibility RH10M residual current protection relay
RH10P residual current protection relay
RH197M residual current protection relay
RH197P residual current protection relay
RH21M residual current protection relay
RH21P residual current protection relay
RH68M residual current protection relay
RH86M residual current protection relay
RH86P residual current protection relay
RH99M residual current protection relay
RH99P residual current protection relay
RHU residual current protection relay
RHUs residual current protection relay
RMH residual current protection relay
Range NameVigirex RH10MP, RH21MP, RH99MP, RH197, RHU
COMPLEMENTARY
Current Transformer TypeA type closed toroid
Number Of Ways120 mm inner:
Cable Outer Diameter60-60 mm: 240-240 mm² (maximum)
Calorific Value3.89 MJ
Compatibility CodeMA120
Connections - Terminalsscrew connection 0.22-0.22 mm²
Depth44 mm
Device Applicationequipment monitoring and control
Height164 mm
Market Segmentresidential
small commercial
Mounting Modeclip-on (DIN rail)
fixed (cables)
fixed (plain backplate)
fixed (profiled sheet metal)
fixed (slotted backplate)
Net Weight0.59 kg
Network Frequency45...440 Hz
Residual Short-circuit Withstand Current85 kA / 0.5 s conforming to IEC 60947-2
Transformer Ratio1/1000
Width190 mm
[Icw] Rated Short-time Withstand Current100 kA for 0.5 s
[Uimp] Rated Impulse Withstand Voltage12 kV
[Ui] Rated Insulation Voltage1000 V
ENVIRONMENT
Ambient Air Temperature For Operation-35-70 °C
Ambient Air Temperature For Storage-55-85 °C
Environmental Characteristicexposure to damp heat in service: category C2: 48 hours conforming to IEC 60068-2-56
exposure to damp heat not in service (25...55 °C, RH 95 %) : 28 cycles conforming to IEC 60068-2-30
salt mist: Kb/2 conforming to IEC 60068-2-52
IP Degree Of Protectionconnectors: IP20
IP30
Overvoltage CategoryIV
Pollution Degreelevel 3 conforming to IEC 60664-1
Product CertificationsCE
StandardsIEC 60947-2
OTHER
Poles Descriptionearth leakage current sensor
Write Your Own Review
You're reviewing:Closed Toroid for Residual Current Protection MA - Ø 120 Mm
Your Rating