GJL1213001R0017 - BC6-30-01-07 Mini Contactor 12VDC

ABB
SKU
AB_GJL1213001R0017
Model
BC6-30-01-07
SGD $22.27 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100

Short description of BC6 30 01 07

Catalog No: GJL1213001R0017
BC6-30-01-07 Mini Contactor 12VDC
Country of Origin
Germany (DE)
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 6 To 8 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

The BC6-30-01 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
MAIN SPECIFICATION
ABB Global IDABB.BBCGJL1213001R0017
Business Area (Master Data) NameElectrification
Catalog DescriptionBC6-30-01-07 Mini Contactor 12VDC
Division (Master Data) NameSmart Power
EAN4013614052873
Mini Contactor TypeMini Contactor
Rated Insulation Voltage (Ui)690 volt
acc. to UL/CSA 600 volt
SKU IDGJL1213001R0017
TECHNICAL
Coil Operating Limits(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Conventional Free-air Thermal Current (Ith)Main Circuit 20 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-15) 600 cycles per hour
(AC-3) 600 cycles per hour
(DC-1) 600 cycles per hour
(DC-13) 600 cycles per hour
(DC-3) 600 cycles per hour
Mechanical Durability10000000 cycle
Minimum Switching CapacityAuxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Mounting On DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Power Lossat Rated Operating Conditions per Pole 2 W
at Rated Operating Conditions AC-1 per Pole 1 W
Rated Frequency (f)Control Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Rated Operational Current AC-15 (Ie)(24 V) 4 A
(120 V) 4 A
(500 V) 2 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Tightening TorqueAuxiliary Circuit 0.8 ... 1.1 N·m
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Main Circuit 9 mm
TECHNICAL UL/CSA
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 22-10 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 22-10 AWG
Contact Rating UL/CSAA600
Full Load Amps Motor Use(115 V AC) Single Phase 5.8 A
(200 V AC) Three Phase 4.8 A
(220 ... 240 V AC) Three Phase 6.8 A
(230 V AC) Single Phase 4.9 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 1.7 A
General Use Rating UL/CSA(300 V AC) 12 A
Horsepower Rating UL/CSA(115 V AC) Single Phase 0.25 Hp
(200 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(230 V AC) Single Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 1 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Tightening Torque UL/CSAAuxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Maximum Operating Altitude Permissible2000 m
Resistance To Shock Acc. To IEC 60068-2-2711 ms Pulse 15g
Resistance To Vibrations Acc. To IEC 60068-2-65g / 5 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
EClassV11.0 : 27371003
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
Object Classification CodeQ
UNSPSC39121529
OTHER
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +80 °C
Degree Of ProtectionAuxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Number Of Auxiliary Contacts NC1
Number Of Main Contacts NO3
Number Of Poles3
Product Net Width52.5
Rated Control Circuit Voltage (Uc)12 V DC
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kilovolt
Main Circuit 6 kilovolt
Rated Operational Current AC-1 (Ie)(220 / 240 V) 40 °C 20 ampere
(220 / 240 V) 55 °C 16 ampere
(380 / 440 V) 40 °C 20 ampere
(380 / 440 V) 55 °C 16 ampere
(690 V) 40 °C 6 ampere
(690 V) 55 °C 6 ampere
Rated Operational Power AC-3 (Pe)(230 V) Three Phase 2.2 kW
(400 V) Three Phase 4 kW
(500 V) Three Phase 4 kW
(690 V) Three Phase, NO 3 kW
Rated Operational VoltageAuxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 220 V DC