Loading...
*All information are subjected to changes without prior notice.

GJL1211201R0003 - B6-40-00-03 Mini Contactor 48V 40-450Hz

ABB
SKU
AB_GJL1211201R0003
Model
B6-40-00-03
SGD $20.27 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100

Short description of B6 40 00 03

Catalog No: GJL1211201R0003
B6-40-00-03 Mini Contactor 48V 40-450Hz
Country of Origin
Germany (DE)
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 6 To 8 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

The B6-40-00 mini contactor is a compact 4 pole contactor with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.
MAIN SPECIFICATION
ABB Global IDABB.BBCGJL1211201R0003
Business Area (Master Data) NameElectrification
Catalog DescriptionB6-40-00-03 Mini Contactor 48V 40-450Hz
Division (Master Data) NameSmart Power
EAN4013614051784
Mini Contactor TypeMini Contactor
Rated Insulation Voltage (Ui)690 volt
acc. to UL/CSA 600 volt
SKU IDGJL1211201R0003
TECHNICAL
Coil Operating Limits(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Conventional Free-air Thermal Current (Ith)Main Circuit 20 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-15) 360 cycles per hour
(AC-3) 600 cycles per hour
(DC-1) 600 cycles per hour
(DC-13) 360 cycles per hour
(DC-3) 600 cycles per hour
Mechanical Durability10000000 cycle
Mounting On DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Power Lossat Rated Operating Conditions per Pole 2 W
at Rated Operating Conditions AC-1 per Pole 1 W
Rated Frequency (f)Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Tightening TorqueAuxiliary Circuit 0.8 ... 1.1 N·m
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Main Circuit 9 mm
TECHNICAL UL/CSA
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 22-10 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 22-10 AWG
Full Load Amps Motor Use(115 V AC) Single Phase 5.8 A
(200 V AC) Three Phase 4.8 A
(220 ... 240 V AC) Three Phase 6.8 A
(230 V AC) Single Phase 4.9 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 1.7 A
General Use Rating UL/CSA(300 V AC) 12 A
Horsepower Rating UL/CSA(115 V AC) Single Phase 0.25 Hp
(200 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(230 V AC) Single Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 1 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Tightening Torque UL/CSAAuxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Maximum Operating Altitude Permissible2000 m
Resistance To Shock Acc. To IEC 60068-2-2711 ms Pulse 15g
Resistance To Vibrations Acc. To IEC 60068-2-65g / 5 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
EClassV11.0 : 27371003
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
Object Classification CodeQ
UNSPSC39121529
OTHER
Ambient Air TemperatureOperation -20 ... +55 °C
Storage -40 ... +80 °C
Degree Of ProtectionAuxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Number Of Main Contacts NO4
Number Of Poles4
Product Net Width52.5
Rated Control Circuit Voltage (Uc)48 V AC
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kilovolt
Main Circuit 6 kilovolt
Rated Operational Current AC-1 (Ie)(220 / 240 V) 40 °C 20 ampere
(220 / 240 V) 55 °C 16 ampere
(380 / 440 V) 40 °C 20 ampere
(380 / 440 V) 55 °C 16 ampere
(690 V) 40 °C 6 ampere
(690 V) 55 °C 6 ampere
Rated Operational Power AC-3 (Pe)(230 V) Three Phase 2.2 kW
(400 V) Three Phase 4 kW
(500 V) Three Phase 4 kW
(690 V) Three Phase, NO 3 kW
Rated Operational VoltageAuxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 220 V DC
Write Your Own Review
You're reviewing:GJL1211201R0003 - B6-40-00-03 Mini Contactor 48V 40-450Hz
Your Rating