2CTB815710R0100 - OVR T1-T2 1N 12.5-275s P TS QS Surge Protective Device
ABB
SKU
AB_2CTB815710R0100
Model
OVR-T1-T2-1N-12.5-275s-P-TS-QS
SGD $505.74 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of OVR T1 T2 1N 12.5 275s P TS QS
Catalog No: 2CTB815710R0100
OVR T1-T2 1N 12.5-275s P TS QS Surge Protective Device
OVR T1-T2 1N 12.5-275s P TS QS Surge Protective Device
Country of Origin
Bulgaria (BG)
OVR T1-T2 1N 12.5-275s P TS QS Surge Protective Device
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB2CTB815710R0100 |
Business Area (Master Data) Name | Electrification |
Catalog Description | OVR T1-T2 1N 12.5-275s P TS QS Surge Protective Device |
Division (Master Data) Name | Smart Buildings |
EAN | 3660308524898 |
SKU ID | 2CTB815710R0100 |
TECHNICAL | |
Arrester Class | I II |
Auxiliary Circuit Load | Minimum 12Vdc - 10mA Maximum 250Vac - 1A |
Discharge Current | Nominal 20 kA Maximum 80 kA Total 100 kA |
Follow Current Extinction Capacity If (I Fi) | (L-N) - kA (N-PE) 0.1 kA |
Fuse Size | 2 modular spacing |
Lightning Impulse Current | 12,5 |
Number Of Protected Poles | 2 |
Options Provided | Industry, commercial building |
Position Of Neutral Terminals | Right |
Power Loss | 37 mW |
Preventive Maintenance Feature | Yes |
Product Name | Surge Protective Device |
Product Type | QS |
Short Circuit Withstand Icc | 100 kA |
Short-Circuit Protective Devices | Curve B Breakers ≤ 125 A Curve C Breakers ≤ 125 A gL Type Fuses ≤ 160 A gG Type Fuses ≤ 160 A |
Standards | IEC 61643-11 / EN 61643-11 |
Status Indicator | Yes |
Temporary Overvoltage Test Value (UT) | (L-N) 337 V (N-PE) 1200 V |
Type Of Low Voltage Distribution System | TT TN-S |
Voltage Rating DC | 350 V |
ORDERING | |
Minimum Order Quantity | 1 piece |
Selling Unit Of Measure | piece |
ENVIRONMENTAL | |
Maximum Operating Altitude Permissible | Without Derating 5000 |
CLASSIFICATIONS | |
CN8 | 85363090 |
ETIM 6 | EC001457 - Combined arrester for power supply systems |
ETIM 7 | EC001457 - Combined arrester for power supply systems |
ETIM 8 | EC001457 - Combined arrester for power supply systems |
Object Classification Code | 141BCC |
WEEE B2C / B2B | Business To Business |
OTHER | |
Degree Of Protection | IP20 |
Impulse Current | I (imp, 10 / 350 µs) 12.5 kA I (total, 10 / 350 µs) 25 kA |
Maximum Continuous Operating Voltage (Uc) | (L-PE) 275 V (L-L) - V (L-N) 275 V (N-PE) 255 V |
Mounting Type | DIN rail (top hat rail) 35 mm |
Nominal AC Voltage Of The System (Uo) | 230 / 400 V |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Number Of Poles | 2 |
Product Net Width | 35.6 |
Suitable For | To protect the systems against the transient overvoltage (lightning) |
Version | Plug-in |
Voltage Protection Level ( Up) | (L-N) 1.4 kV (N-PE) 1.4 kV (L-PE) 1.5 kV |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Width In Number Of Modular Spacings | 2 |
Write Your Own Review