2CTB815101R0600 - OVR T1 3L 25-255 TS Surge Protective Device
ABB
SKU
AB_2CTB815101R0600
Model
OVR-T1-3L-25-255-TS
Obsolete
Short description of OVR T1 3L 25 255 TS
Catalog No: 2CTB815101R0600
OVR T1 3L 25-255 TS Surge Protective Device
OVR T1 3L 25-255 TS Surge Protective Device
Obsolete
510106
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB2CTB815101R0600 |
Business Area (Master Data) Name | Electrification |
Catalog Description | OVR T1 3L 25-255 TS Surge Protective Device |
Division (Master Data) Name | Smart Buildings |
EAN | 3660308510952 |
SKU ID | 2CTB815101R0600 |
TECHNICAL | |
Arrester Class | I |
Auxiliary Circuit Load | Minimum 12Vdc - 10mA Maximum 250Vac - 1A |
Discharge Current | Nominal 25 kA Maximum 60 kA Total 75 kA |
Follow Current Extinction Capacity If (I Fi) | 50 kA |
Fuse Size | 6 modular spacing |
Lightning Impulse Current | 25 |
Number Of Protected Poles | 3 |
Options Provided | Industry, commercial building |
Preventive Maintenance Feature | No |
Product Name | Surge Protective Device |
Short Circuit Withstand Icc | 50 kA |
Short-Circuit Protective Devices | Curve B Breakers ≤ 125 A Curve C Breakers ≤ 125 A gL Type Fuses ≤ 125 A gG Type Fuses ≤ 125 A |
Standards | IEC 61643-1:2005 |
Status Indicator | Yes |
Temporary Overvoltage Test Value (UT) | 337 V |
Type Of Low Voltage Distribution System | TN-C |
ORDERING | |
Minimum Order Quantity | 1 piece |
Selling Unit Of Measure | piece |
CLASSIFICATIONS | |
CN8 | 85363090 |
E-Number (Finland) | 3210882 |
E-Number (Sweden) | 5273502 |
ETIM 6 | EC000381 - Lightning current arrester for power supply systems |
ETIM 7 | EC000381 - Lightning current arrester for power supply systems |
ETIM 8 | EC000381 - Lightning current arrester for power supply systems |
Object Classification Code | 141ACC |
WEEE B2C / B2B | Business To Business |
OTHER | |
Degree Of Protection | IP20 |
Impulse Current | I (imp, 10 / 350 µs) 25 kA I (total, 10 / 350 µs) - kA |
Maximum Continuous Operating Voltage (Uc) | (L-PE) 255 V (L-L) 440 V (L-N) - V (N-PE) - V |
Mounting Type | DIN rail (top hat rail) 35 mm |
Nominal AC Voltage Of The System (Uo) | 230 / 400 V |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Number Of Poles | 3 |
Product Net Width | 124.6 |
Suitable For | To protect the systems against the transient overvoltage (lightning) |
Version | Fix |
Voltage Protection Level ( Up) | (L-N) - kV (N-PE) - kV (L-PE) 2.5 kV |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Width In Number Of Modular Spacings | 7 |