Short description of ELR72P
Catalog No: 2CSG152424R1202
ELR72P Residual Current Monitor
ELR72P Residual Current Monitor
Country of Origin
Italy (IT)
The ELR electronic residual current relay allows monitoring and protection of thelow voltage distribution network, through the use of a toroidal transformer.Protection is achieved in combination with the MCBs and MCCBs. The ELR front panel residual current relay is compliant with protection standard 60947-2 Annex M in order to offer a cumulative operational time (residual current relay, shunt-trip, circuit breaker) guaranteed by the manufacturer.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB2CSG152424R1202 |
Business Area (Master Data) Name | Electrification |
Catalog Description | ELR72P - Residual Current Monitor |
Division (Master Data) Name | Smart Buildings |
EAN | 8012542734727 |
SKU ID | 2CSG152424R1202 |
TECHNICAL | |
Current Rating | Response value amperage 1 30 ... 30 mA Response value amperage 2 30000 ... 30000 mA |
Delay Time (?) | Delay-On Energization, Maximum, Permitted 5 second [unit of time] Delay-On Energization, Minimum, Adjustable 0 second [unit of time] |
Filter Option | no frequency filter |
Options Provided | Pre-alarm threshold: 60% |
Power Loss | at Rated Operating Conditions per Pole 4 W |
Product Name | Residual Current Monitor |
Rated Frequency (f) | 50...60 Hz |
Standards | IEC EN 60947-2 Ann M |
DIMENSIONS | |
Dimensions | 72 mm x 72 mm |
ORDERING | |
Minimum Order Quantity | 1 piece |
Selling Unit Of Measure | piece |
ENVIRONMENTAL | |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
CN8 | 85363030 |
ETIM 6 | EC001445 - Residual current monitoring relay |
ETIM 7 | EC001445 - Residual current monitoring relay |
ETIM 8 | EC001445 - Residual current monitoring relay |
Object Classification Code | F |
WEEE B2C / B2B | Business To Business |
OTHER | |
Function | For AC-current system |
Mounting Type | front panel |
Number Of Contacts | 2 |
Number Of Contacts CO | 2 |
Product Net Width | 72 |
Rated Control Supply Voltage (Us) | (50 Hz) 110...400 V (60 Hz) 110...400 V |
Rated Operational Voltage | 115-230-400 V AC |
Rated Voltage (Ur) | 110...400 V |
Type Of Residual Current | A type |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |