Loading...
*All information are subjected to changes without prior notice.

1SFL431024R8000 - UA95-30-00RA-80 - UA95-30-00RA 220-230V 50Hz Contactor

ABB
SKU
AB_1SFL431024R8000
Model
UA95-30-00RA-80
SGD $756.20 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100

Short description of UA95 30 00RA 80

Catalog No: 1SFL431024R8000
UA95-30-00RA 220-230V 50Hz Contactor
Country of Origin
Sweden (SE)
-
+

UOM: Piece

In stock
In Stock 5
Backorder Leadtime: 8 To 10 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

A 3-phase Contactor suitable for Capacitor switching application. Maximum permissible peak current 100 times the nominal RMS current. Operated with a control voltage, versions from 24…….690 V
MAIN SPECIFICATION
ABB Global IDABB1SFL431024R8000
Business Area (Master Data) NameElectrification
Catalog DescriptionUA95-30-00RA 220-230V 50Hz Contactor
Division (Master Data) NameSmart Power
EAN7320500260425
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
acc. to UL/CSA 600 volt
SKU ID1SFL431024R8000
TECHNICAL
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting Capacity Main CircuitBar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 2 x 6 ... 65 mm²
Connecting Terminals (delivered In Open Position) Main PolesM8 hexagon socket screw with single connector
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Mechanical Durability10 million
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Rated Breaking Capacity AC-3 Acc. To IEC 60947-4-18 x Ie AC-3
Rated Frequency (f)Main Circuit 50 Hz
Rated Making Capacity AC-3 Acc. To IEC 60947-4-110 x Ie AC-3
Terminal TypeCable Clamp
TECHNICAL UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Maximum Operating Altitude Permissible3000 m
Resistance To Shock Acc. To IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 K40
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
CLASSIFICATIONS
E-Number (Finland)3709347
EClassV11.0 : 27371006
ETIM 4EC001079 - Capacitor magnet contactor
ETIM 5EC001079 - Capacitor magnet contactor
ETIM 6EC001079 - Capacitor contactor
ETIM 7EC001079 - Capacitor contactor
IDEA Granular Category Code (IGCC)4756 >> Capacitor magnet contactor
Object Classification CodeQ
UNSPSC39121529
OTHER
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Degree Of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Number Of Main Contacts NO3
Number Of Poles3
Product Net Width90
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kilovolt
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 145 No unit
(690 V) 55 °C 135 No unit
(690 V) 60 °C 135 ampere
(690 V) 70 °C 115 No unit
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(500 V) 55 °C 80 A
(690 V) 55 °C 65 A
(1000 V) 55 °C 30 A
(380 / 400 V) 55 °C 96 A
(220 / 230 / 240 V) 55 °C 96
Rated Operational Power AC-3 (Pe)(380 / 400 V) 45 kW
Rated Operational Power AC-6b (Pe)(230 / 240 V) 40 °C, 50 / 60 Hz 40 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 35 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 30 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 70 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar
(440 V) 40 °C, 50 / 60 Hz 75 kvar
(440 V) 55 °C, 50 / 60 Hz 65 kvar
(440 V) 70 °C, 50 / 60 Hz 58 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 85 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar
(690 V) 40 °C, 50 / 60 Hz 120 kvar
(690 V) 55 °C, 50 / 60 Hz 105 kvar
(690 V) 70 °C, 50 / 60 Hz 85 kvar
Rated Operational VoltageMain Circuit 1000 V
Write Your Own Review