1SBL351074R8011 - AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
ABB
SKU
AB_1SBL351074R8011
Model
AX50-30-11-80
SGD $107.13 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of AX50 30 11 80
Catalog No: 1SBL351074R8011
AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
Country of Origin
Bulgaria (BG)
AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SBL351074R8011 |
Business Area (Master Data) Name | Electrification |
Catalog Description | AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor |
Division (Master Data) Name | Smart Power |
EAN | 3471522404800 |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 volt |
SKU ID | 1SBL351074R8011 |
TECHNICAL | |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour (AC-3) 600 cycles per hour |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 8 ... 27 ms |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A for 1 s -empty- A |
Terminal Type | Screw Terminals |
TECHNICAL UL/CSA | |
General Use Rating UL/CSA | (600 V AC) 80 A |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 Hp (240 V AC) Single Phase 10 Hp (200 ... 208 V AC) Three Phase 15 Hp (220 ... 240 V AC) Three Phase 20 Hp (440 ... 480 V AC) Three Phase 40 Hp (550 ... 600 V AC) Three Phase 50 Hp |
Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 35 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Climatic Withstand | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible | 3000 m |
RoHS Status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
CLASSIFICATIONS | |
ETIM 6 | EC000066 - Power contactor, AC switching |
ETIM 7 | EC000066 - Power contactor, AC switching |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Object Classification Code | Q |
UNSPSC | 39121529 |
OTHER | |
Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Near Contactor for Operation in Free Air -40 ... +70 °C |
Degree Of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Number Of Main Contacts NO | 3 |
Product Net Width | 82 |
Rated Control Circuit Voltage (Uc) | 50 Hz 220 ... 230 V 60 Hz 230 ... 240 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kilovolt |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 100 ampere (690 V) 70 °C 70 ampere (220 / 240 V) 55 °C 85 ampere |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 53 A (380 / 400 V) 55 °C 50 A (415 V) 55 °C 50 A (440 V) 55 °C 45 A (500 V) 55 °C 45 A (690 V) 55 °C 35 A |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 15 kW (380 / 400 V) 22 kW (415 V) 25 kW (440 V) 25 kW (500 V) 30 kW (690 V) 30 kW |
Rated Operational Voltage | Auxiliary Circuit 690 V Main Circuit 690 V |