
1SAM360000R1014 - MO132-25 Manual Motor Starter Magnetic Only
ABB
SKU
AB_1SAM360000R1014
Model
MO132-25
SGD $79.70 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of MO132 25
Catalog No: 1SAM360000R1014
MO132-25 Manual Motor Starter Magnetic Only
MO132-25 Manual Motor Starter Magnetic Only
Country of Origin
Germany (DE)
The MO132-25 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SAM360000R1014 |
Business Area (Master Data) Name | Electrification |
Catalog Description | MO132-25 Manual Motor Starter Magnetic only, 25A |
Division (Master Data) Name | Smart Power |
EAN | 4013614400292 |
Rated Insulation Voltage (Ui) | 690 volt |
Rated Operation Current | 25 ampere |
SKU ID | 1SAM360000R1014 |
TECHNICAL | |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² Flexible 1/2x 1 ... 2.5 mm² Flexible 1/2x 2.5 ... 6 mm² Rigid 1/2x 1 ... 2.5 mm² Rigid 1/2x 2.5 ... 6 mm² |
Contact Position Indication | ON / OFF / TRIP |
Conventional Free-air Thermal Current (Ith) | Main Circuit 25 A |
Electrical Durability | 50000 cycle |
Mechanical Durability | 100000 cycle |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm |
Mounting On DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting Position | Position 1 to 6 |
Pollution Degree | 3 |
Power Loss | at Rated Operating Conditions per Pole 2.2 W |
Rated Frequency (f) | Main Circuit 50 Hz Main Circuit 60 Hz |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 313 A |
Rated Operational Current (Ie) | 25 A |
Rated Operational Current AC-3e (Ie) | 25 A |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 11 kW |
Recommended Screw Driver | Pozidriv 2 |
Remarks | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
Standards | IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 |
Terminal Type | Screw Terminals |
Tightening Torque | Main Circuit 2 N·m |
Wire Stripping Length | Main Circuit 10 mm |
TECHNICAL UL/CSA | |
Ampere Rating UL/CSA | 25 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWG Stranded 1/2x 16-8 AWG |
Full Load Amps Motor Use | (200 V AC) Three Phase 17.5 A (208 V AC) Three Phase 24.2 A (220 ... 240 V AC) Three Phase 22 A (440 ... 480 V AC) Three Phase 21 A (550 ... 600 V AC) Three Phase 22 A |
General Use Rating UL/CSA | (600 V AC) 25 A |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 5 Hp (208 V AC) Three Phase 7.5 Hp (220 ... 240 V AC) Three Phase 7.5 Hp (440 ... 480 V AC) Three Phase 15 Hp (550 ... 600 V AC) Three Phase 20 Hp |
Locked Rotor Amps | (200 V AC) Three Phase 105.8 A (208 V AC) Three Phase 140 A (220 ... 240 V AC) Three Phase 127 A (440 ... 480 V AC) Three Phase 116 A (550 ... 600 V AC) Three Phase 116 A |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA |
Tightening Torque UL/CSA | Main Circuit 18 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Ambient Air Temperature Compensation | No |
Maximum Operating Altitude Permissible | 2000 m |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 25g |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5g / 3 ... 150 Hz |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 3705892 |
E-Number (Sweden) | 3110042 |
EClass | V11.0 : 27370401 |
ETIM 4 | EC000074 - Motor protective circuit-breaker |
ETIM 5 | EC000074 - Motor protective circuit-breaker |
ETIM 6 | EC000074 - Motor protection circuit-breaker |
ETIM 7 | EC000074 - Motor protection circuit-breaker |
IDEA Granular Category Code (IGCC) | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
Object Classification Code | F |
UNSPSC | 39121521 |
OTHER | |
Actuator Type | Rotary Handle |
Ambient Air Temperature | Around the Enclosure 0 ... +40 °C Operation -25 ... +60 °C Storage -50 ... +80 °C |
Degree Of Protection | Housing IP20 Main Circuit Terminals IP10 |
Number Of Poles | 3 |
Product Net Width | 45 |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kilovolt |
Rated Operational Current AC-3 (Ie) | 25 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 11 kW |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 20 kA (500 V AC) 10 kA (690 V AC) 3 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 20 kA (500 V AC) 10 kA (690 V AC) 3 kA |
Setting Range | None |
Write Your Own Review