The MO132-2.5 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 2.50 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
MAIN SPECIFICATION
ABB Global IDABB1SAM360000R1007
Business Area (Master Data) NameElectrification
Catalog DescriptionMO132-2.5 Manual Motor Starter Magnetic only, 2.5A
Division (Master Data) NameSmart Power
EAN4013614400223
Rated Insulation Voltage (Ui)690 volt
Rated Operation Current2.5 ampere
SKU ID1SAM360000R1007
TECHNICAL
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Contact Position IndicationON / OFF / TRIP
Conventional Free-air Thermal Current (Ith)Main Circuit 2.5 A
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Mounting On DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionPosition 1 to 6
Pollution Degree3
Power Lossat Rated Operating Conditions per Pole 1.7 W
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Instantaneous Short-Circuit Current Setting (Ii)31.3 A
Rated Operational Current (Ie)2.5 A
Rated Operational Current AC-3e (Ie)2.5 A
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.75 kW
Recommended Screw DriverPozidriv 2
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used
StandardsIEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Terminal TypeScrew Terminals
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
TECHNICAL UL/CSA
Ampere Rating UL/CSA2.5 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Full Load Amps Motor Use(200 V AC) Three Phase 2.5 A
(208 V AC) Three Phase 2.5 A
(220 ... 240 V AC) Three Phase 2.5 A
(440 ... 480 V AC) Three Phase 2.5 A
(550 ... 600 V AC) Three Phase 2.5 A
General Use Rating UL/CSA(600 V AC) 2.5 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 0.5 Hp
(208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 1 Hp
(550 ... 600 V AC) Three Phase 1.5 Hp
Locked Rotor Amps(200 V AC) Three Phase 15 A
(208 V AC) Three Phase 15 A
(220 ... 240 V AC) Three Phase 15 A
(440 ... 480 V AC) Three Phase 15 A
(550 ... 600 V AC) Three Phase 15 A
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Tightening Torque UL/CSAMain Circuit 10 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Ambient Air Temperature CompensationNo
Maximum Operating Altitude Permissible2000 m
Resistance To Shock Acc. To IEC 60068-2-2711 ms Pulse 25g
Resistance To Vibrations Acc. To IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
E-Number (Finland)3705885
E-Number (Sweden)3110035
EClassV11.0 : 27370401
ETIM 4EC000074 - Motor protective circuit-breaker
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
ETIM 7EC000074 - Motor protection circuit-breaker
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Object Classification CodeF
UNSPSC39121521
OTHER
Actuator TypeRotary Handle
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Degree Of ProtectionHousing IP20
Main Circuit Terminals IP10
Number Of Poles3
Product Net Width45
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kilovolt
Rated Operational Current AC-3 (Ie)2.5 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.75 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Setting RangeNone