D4B-4A70N - SAFETY LIMIT SWITCH
Omron
SKU
OM_D4BN4017R
Model
D4B-4A70N
SGD $91.17 All prices inclusive of GST
Short description of D4B 4A70N
D4B-4A70N - Safety Limit switch, D4B, M20, DPDB 2-NC (slow-action), top plunger
Country of Origin
JAPAN
Safety Limit switch, D4B, M20, DPDB 2-NC (slow-action), top plunger
Cable Entry Direction | Bottom |
---|---|
Conduit Size | M20 |
Rated Current | 10A (carry current,A600) |
Rated Power | (make,A600) 7200 VA |
Speed | 0.001...0.5m/s operating speed |
Switch Action | Slow action |
Action Type | Slow Action |
Actuator Type | Plunger |
Ambient Air Temperature For Operation | -40...+80 °C |
Benefits | Direct opening mechanism (NC contacts only) added to enable opening contacts when faults occur, such as fused contacts. |
Compliant With Standard(S) | EN ISO 14119 |
Connection Method | Terminal block |
Connection Type | 1 x term. wiring chamber with M20 cond. entry |
Contacts Type | 2NC (slow-action) |
Degree Of Pollution | 3 (as per EN60947-5-1) |
Degree Of Protection | IP67 |
Degree Of Protection (Ip) | IP67 |
Design | pin plunger |
Direct Opening Mechanism | 1 |
Distance | 2 x 2mm min. contact gap |
Ean Code | 4536854776663 |
Electrical Durability (With Load) | (10A resistive load at 250Vac) min. 500 000 operations |
Frequency | 120 operations/minute (mechanical) |
Functions | Complete safety limit switch |
Housing Material | Metal |
Ip Rating | IP67 |
Legislation And Compliance | RoHS Certificate of Compliance |
Load Type | Standard load |
Location Of Origin | Japan |
Main Function | Safety limit switch |
Manufacturer Product Status | Commercialized |
Material Housing | Aluminium |
Maximum Ac Voltage | 400V |
Maximum Current | 10A |
Mechanical Durability (At No Load) | min. 10 000 000 operations |
Network Frequency | 50/60 Hz |
Normal State Configuration | 2NC |
Number Of Contacts| Normally-Closed | 2 |
Number Of Normally Closed (Nc) Circuits | 2 NC Pole(s) |
Number Of Normally Open (No) Circuits | 0 NO Pole(s) |
Product Series / Family Name | D4B-N series |
Protection Functions | Class I electric shock protection (with ground terminal) |
Rated Impulse Voltage (Uimp) | (between terminals of same polarity) 2.5 kV |
Rated Insulation Voltage (Ui) | (EN60947-5-1) 600 V |
Rated Operating Voltage Ue | (AC-15) 400 V |
Rated Voltage (Ac) | 120Vac (A600, 60A make current) |
Resistance (Ω) | 25mΩ max. (contact resistance) |
Secondary Brand | STi |
Write Your Own Review