XMLA010A2S13 - Electromechanical Pressure Sensor, Pressure Sensors XM, Switch XMLA 10 Bar, Fixed Scale 1 Threshold, 1 C/O.
Telemecanique
SKU
SE_XMLA010A2S13
Model
XMLA010A2S13
SGD $204.12 All prices inclusive of GST
Short description of XMLA010A2S13
XMLA010A2S13. Sensors for pressure control
Country of Origin
Czechia
range of product : OsiSense XM
-  product or component type : Electromechanical pressure sensor
-  pressure sensor type : Electromechanical pressure sensor
-  device short name : XMLA
-  pressure rating : 10 bar
-  controlled fluid : Air (0…70 °C)Fresh water (0…70 °C)Hydraulic oil (0…70 °C)
-  fluid connection type : 1/4"
-  18 NPTF (female)
-  electrical connection : Screw
- clamps terminals, 1 x 0.5...2 x 2.5 mm²
-  AWG gauge : AWG 20...AWG 14
-  cable entry : Cable gland 7…13 mm
-  contacts type and composition : 1 C/O
-  product specific application : 
- 
-  pressure switch type of operation : Detection of 1 single threshold
-  electrical circuit type : Control circuit
-  scale type : Fixed differential
-  local display : With
-  adjustable range of switching point on rising pressure : 0.6…10 bar
-  adjustable range of switching point on falling pressure : 0.1…9.5 bar
-  maximum permissible accidental pressure : 22.5 bar
-  destruction pressure : 45 bar
-  pressure actuator : Diaphragm
-  materials in contact with fluid : Zinc alloyFPM, FKM
-  enclosure material : Zinc alloy
-  [In] rated current : 3 A, B300, AC
- 15 (Ue = 120 V) conforming to EN/IEC 60947-5-11.5 A, B300, AC
- 15 (Ue = 240 V) conforming to EN/IEC 60947-5-10.1 A, R300, DC
- 13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
-  product or component type : Electromechanical pressure sensor
-  pressure sensor type : Electromechanical pressure sensor
-  device short name : XMLA
-  pressure rating : 10 bar
-  controlled fluid : Air (0…70 °C)Fresh water (0…70 °C)Hydraulic oil (0…70 °C)
-  fluid connection type : 1/4"
-  18 NPTF (female)
-  electrical connection : Screw
- clamps terminals, 1 x 0.5...2 x 2.5 mm²
-  AWG gauge : AWG 20...AWG 14
-  cable entry : Cable gland 7…13 mm
-  contacts type and composition : 1 C/O
-  product specific application : 
- 
-  pressure switch type of operation : Detection of 1 single threshold
-  electrical circuit type : Control circuit
-  scale type : Fixed differential
-  local display : With
-  adjustable range of switching point on rising pressure : 0.6…10 bar
-  adjustable range of switching point on falling pressure : 0.1…9.5 bar
-  maximum permissible accidental pressure : 22.5 bar
-  destruction pressure : 45 bar
-  pressure actuator : Diaphragm
-  materials in contact with fluid : Zinc alloyFPM, FKM
-  enclosure material : Zinc alloy
-  [In] rated current : 3 A, B300, AC
- 15 (Ue = 120 V) conforming to EN/IEC 60947-5-11.5 A, B300, AC
- 15 (Ue = 240 V) conforming to EN/IEC 60947-5-10.1 A, R300, DC
- 13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
MAIN SPECIFICATIONS | |
---|---|
Contacts Type And Composition | 1 C/O |
Discrete Input Number | 1 C/O |
Pressure Sensor Size | 10 bar |
Pressure Sensor Type | electromechanical pressure sensor |
Product Or Component Type | electromechanical pressure sensor |
Range Of Product | OsiSense XM |
Adjustable Range Of Switching Point On Falling Pressure | 0.1-9.5 bar |
Adjustable Range Of Switching Point On Rising Pressure | 0.6-10 bar |
Device Short Name | XMLA |
Electrical Circuit Type | control circuit |
Enclosure Material | zinc alloy |
Fluid Connection Type | 1/4" - 18 NPTF (female) |
Materials In Contact With Fluid | FPM, FKM zinc alloy |
Pressure Actuator | diaphragm |
Pressure Switch Type Of Operation | detection of 1 single threshold |
Product Specific Application | - |
Range Name | OsiSense XM |
Scale Type | fixed differential |
Short-circuit Protection | 10 A cartridge fuse, type gG (gl) |
Terminal Block Type | 4 terminals |
COMPLEMENTARY | |
Analogue Output Type | 10 bar |
[In] Rated Current | 0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1 1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1 3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1 |
Auxiliary Contacts Operation | snap action |
AWG Gauge | AWG 20...AWG 14 |
Cable Entry | cable gland 7-13 mm |
Contacts Material | silver contacts |
Controlled Fluid | air (0-70 °C) fresh water (0-70 °C) hydraulic oil (0-70 °C) |
Depth | 75 mm |
Destruction Pressure | 45 bar |
Electrical Connection | screw-clamps terminals, 1 x 0.5...2 x 2.5 mm² |
Height | 113 mm |
Local Display | with |
Maximum Operating Rate | 120 cyc/mn |
Maximum Permissible Accidental Pressure | 22.5 bar |
Maximum Permissible Pressure - Per Cycle | 12.5 bar |
Maximum Resistance Across Terminals | 25 mOhm conforming to IEC 255-7 category 3 25 MOhm conforming to NF C 93-050 method A |
Mechanical Durability | 5000000 cycles |
Natural Differential At High Setting | 0.5 bar (+/- 0.05 bar) |
Natural Differential At Low Setting | 0.5 bar (+/- 0.05 bar) |
Net Weight | 0.685 kg |
Operating Position | any position |
Repeat Accuracy | 2 % |
Setting | external |
Terminals Description ISO N°1 | (13-14-11-12)OF |
Width | 35 mm |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to EN/IEC 60947-1 |
[Ui] Rated Insulation Voltage | 300 V conforming to CSA C22.2 No 14 300 V conforming to UL 508 500 V conforming to EN/IEC 60947-1 |
ENVIRONMENT | |
Safety Level | electromechanical pressure sensor |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class I conforming to IEC 1140 class I conforming to IEC 536 class I conforming to NF C 20-030 |
IP Degree Of Protection | IP66 conforming to EN/IEC 60529 |
Product Certifications | BV CCC CSA EAC LROS (Lloyds register of shipping) UL |
Protective Treatment | TC standard version |
Shock Resistance | 50 gn conforming to IEC 60068-2-27 |
Standards | CE CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 |
Vibration Resistance | 4 gn conforming to IEC 60068-2-6 (f = 30-500 Hz) |
OTHER | |
Poles Description | electromechanical pressure sensor |
[Us] Rated Supply Voltage | OsiSense XM |