Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Safety Relay Unit

Omron
SKU
OM_G9SA6007G
Model
G9SA-EX301
SGD $333.57

Short description of G9SA EX301

Expansion unit for G9SA, 3PST-NO (Category 4), 5 A, SPST-NC aux
Country of Origin
CHINA
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 To 6 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Rated Current30mA max. added to the connected unit
TypeOutput Module
Ambient Air Temperature For Operation-25...+55 °C
ClassPL.e / Cat4
Compliant With Standard(S)EN ISO 13849-1 - PL e/Category 4
Design1 or 2 input channel
Digital Inputs1 x safety input 1 (T11, T12)
Digital Outputs1 x instantaneous safety output (3PST each with 2NO contacts in series) (13-14, 23-24, 33-34)
Dimensions76 x 17.5 x 111 mm
Ean Code4547648814003
Electrical Durability (With Load)(approx. 1800 operations/hour, 15-35°C) min. 100 000 operations
For Use WithG9SA
FunctionsSafety relay expansion unit
Legislation And ComplianceRoHS Certificate of Compliance
Location Of OriginChina
Main FunctionSafety relay
Manufacturer Product StatusCommercialized
Mechanical Durability (At No Load)(approx. 7200 operations/hour, 15-35°C) min. 5 000 000 operations
Mounting ModeDIN rail
Mounting StyleDIN Rail
Normal State Configuration3NO/1NC
Number Of Outputs2
Power Consumption(added to connected unit) max. 2 W
Power Rating1.7 W
Product Depth111 mm
Product Height98.2 mm
Product Series / Family NameG9SA series
Product Width17.5 mm
Rated Impulse Voltage (Uimp)(isolation) 4 kV
Rated Insulation Voltage (Ui)(isolation voltage, AC) 250 V
Rated Operating Voltage Ue(failure rate, P level, reference value) 1mA, (DC) 5 V
Rated Voltage (Ac)2500Vac (for 1 min., dielectric strength, between input and output, between different poles of output)
Resistance (Ω)100mΩ (contact resistance, measured with 1A at 5Vdc using voltage drop method)
Response Time(OFF=>ON,not include bounce time) max. 30ms / max. 0.03 s
Safety ApplicationExpansion
Secondary BrandSTi
SeriesG9SA
Supply Voltage24 V dc
Supply Voltage Ac110-240Vac (120Vac / 220Vac / 230Vac nom.) (50/60Hz)
Supply Voltage Dc24Vdc
Terminal TypeScrew
Tightening Torque(terminal) 0.6 N.m
Time Delay(response time) 0.010 s
Write Your Own Review
You're reviewing:Safety Relay Unit