PM5650 Meter, 2 Ethernet, Up To 63th H, 1,1M, Waveform, 4DI/2DO 52 Alarms
Schneider
SKU
SE_METSEPM5650
Model
METSEPM5650
SGD $3,717.58 All prices inclusive of GST
Short description of METSEPM5650
PM5650, PANEL MOUNT, WC+SS
Country of Origin
India
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 100...480 V AC 45...65 Hz 125...250 V DC |
Contacts Type And Composition | 1 A 5 A |
Control Type | 1P + N 3P 3P + N |
Display Type | backlit LCD |
Measurement Accuracy | active energy +/- 0.2 % active power +/- 0.2 % apparent power +/- 0.5 % current +/- 0.1 % frequency +/- 0.05 % power factor +/- 0.005 reactive energy +/- 2 % voltage +/- 0.1 % |
Mounting Diameter | 4 digital |
Number Of Doors | Ethernet/serial |
Product Or Component Type | power meter |
Web Server | 1.1 MB |
Communication Port Protocol | BACnet IP Ethernet Modbus TCP/IP daisy chain JBUS Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V |
Device Short Name | PM5650 |
EAN13 | 3606489869717 |
Mounting Support | framework |
Power Quality Analysis | up to the 63rd harmonic voltage sag and swell detection waveform capture |
Range | PowerLogic |
Range Name | PM5000 series |
Type Of Measurement | active and reactive power current energy frequency power factor voltage |
COMPLEMENTARY | |
Analogue Input Type | current (impedance 0.3 mOhm) voltage (impedance 5 MOhm) |
Analogue Output Number | backlit LCD |
Communication Gateway | Ethernet/serial |
Display Resolution | 128 x 128 pixels |
Memory Capacity | 1.1 MB |
Number Of Inputs | 4 digital |
Output Voltage | current (impedance 0.3 mOhm) voltage (impedance 5 MOhm) |
Product Name | PowerLogic PM5000 |
Time Delay | active energy +/- 0.2 % active power +/- 0.2 % apparent power +/- 0.5 % current +/- 0.1 % frequency +/- 0.05 % power factor +/- 0.005 reactive energy +/- 2 % voltage +/- 0.1 % |
[In] Rated Current | 1 A 5 A |
Accuracy Class | class 0.2S active energy conforming to IEC 62053-22 |
Communication Port Support | Ethernet RS485 |
Compatibility Code | PM5650 |
Connections - Terminals | control circuit: screw terminal block2 current transformer: screw terminal block6 digital input: screw terminal block8 digital output: screw terminal block4 Ethernet network: RJ45 connector2 RS485 link: screw terminal block4 voltage circuit: screw terminal block4 |
Data Recording | alarm logs data logs event logs maintenance logs min/max of instantaneous values time stamping |
Depth | 72 mm |
Device Application | gateway multi-tariff power monitoring WAGES metering |
Ethernet Service | SNMP-Traps SNTP client |
Frequency Measurement Range | 45-65 Hz |
Height | 96 mm |
Information Displayed | tariff (8) |
Market Segment | buildings large building cost management: billing: main incomer buildings large building cost management: billing: sub feeder buildings large building cost management: cost allocation: main incomer buildings large building cost management: cost allocation: sub feeder buildings large building network management: sub feeder buildings medium building cost management: billing: main incomer buildings medium building cost management: billing: sub feeder buildings medium building cost management: cost allocation: main incomer buildings medium building cost management: cost allocation: sub feeder buildings medium building network management: main incomer buildings medium building network management: sub feeder buildings multi-site cost management: billing: main incomer buildings multi-site cost management: billing: sub feeder buildings multi-site cost management: cost allocation: main incomer buildings multi-site cost management: cost allocation: sub feeder buildings multi-site network management: sub feeder buildings small building cost management: billing: main incomer buildings small building cost management: billing: sub feeder buildings small building cost management: cost allocation: main incomer buildings small building cost management: cost allocation: sub feeder buildings small building network management: main incomer buildings small building network management: sub feeder data center cost management: billing: main incomer data center cost management: billing: sub feeder data center cost management: cost allocation: main incomer data center cost management: cost allocation: sub feeder data center network management: sub feeder healthcare cost management: billing: main incomer healthcare cost management: billing: sub feeder healthcare cost management: cost allocation: main incomer healthcare cost management: cost allocation: sub feeder healthcare network management: sub feeder industry cost management: billing: main incomer industry cost management: billing: sub feeder industry cost management: cost allocation: main incomer industry cost management: cost allocation: sub feeder industry network management: sub feeder |
Maximum Power Consumption In VA | 10 VA at 480 V |
Measurement Current | 5-10000 mA |
Measurement Voltage | 20-400 V AC 45...65 Hz between phase and neutral 20-690 V AC 45...65 Hz between phases |
Metering Type | calculated ground current measured neutral current |
Mounting Mode | flush-mounted |
Net Weight | 450 g |
Network Frequency | 50 Hz 60 Hz |
Number Of Outputs | 2 digital |
Ride-through Time | 129 ms 230 V AC typical 35 ms 120 V AC typical |
Sampling Rate | 128 samples/cycle |
Web Services | alarm notification by e-mail diagnostic via predefined web pages real time viewing of data web server |
Width | 96 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
Electromagnetic Compatibility | conducted and radiated emissions class B conforming to EN 55022 conducted RF disturbances level 3 conforming to IEC 61000-4-6 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2 limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 limits for harmonic current emissions class A conforming to IEC 61000-3-2 magnetic field at power frequency level 4 conforming to IEC 61000-4-8 radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 surge immunity test level 4 conforming to IEC 61000-4-5 voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
IP Degree Of Protection | IP30 body: conforming to IEC 60529 IP52 front: conforming to IEC 60529 |
Operating Altitude | 3000 m |
Pollution Degree | 2 |
Product Certifications | CE conforming to IEC 61010-1 cULus conforming to UL 61010-1 |
Relative Humidity | 5-95 % at 50-50 °C |
Standards | EN 50470-1 EN 50470-3 IEC 60529 IEC 61557-12 IEC 62053-22 IEC 62053-24 UL 61010-1 |
OTHER | |
Poles Description | 1P + N 3P 3P + N |
[Us] Rated Supply Voltage | 100...480 V AC 45...65 Hz 125...250 V DC |
Write Your Own Review