1SBE121111R0620 - ESB20-20N-06 Installation Contactor
ABB
SKU
AB_1SBE121111R0620
Model
ESB20-20N-06
SGD $18.75 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of ESB20 20N 06
Catalog No: 1SBE121111R0620
ESB20-20N-06 Installation Contactor
The ESB20..N installation contactors are used to control single loads up to 20 A and can be operated by AC or DC.
These contactors are made for use in household applications as well as in industrial environments.
The following benefits are provided:
- Hum-free operation, low power consumption and integrated overvoltage protection.
- Various contact combinations and accessories are available.
ESB20-20N-06 Installation Contactor
The ESB20..N installation contactors are used to control single loads up to 20 A and can be operated by AC or DC.
These contactors are made for use in household applications as well as in industrial environments.
The following benefits are provided:
- Hum-free operation, low power consumption and integrated overvoltage protection.
- Various contact combinations and accessories are available.
Country of Origin
Bulgaria (BG)
The ESB20..N installation contactors are used to control single loads up to 20 A and can be operated by AC or DC. <br />These contactors are made for use in household applications as well as in industrial environments.<br />The following benefits are provided: <br />Hum-free operation, low power consumption and integrated overvoltage protection. <br />Various contact combinations and accessories are available.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SBE121111R0620 |
Business Area (Master Data) Name | Electrification |
Catalog Description | ESB20-20N-06 Installation Contactor 2NO/0NC, 230V AC/DC |
Division (Master Data) Name | Smart Power |
EAN | 3471523007505 |
Rated Insulation Voltage (Ui) | 400 volt |
SKU ID | 1SBE121111R0620 |
TECHNICAL | |
Connecting Capacity Control Circuit | Flexible with Ferrule 1x 1 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 2.5 mm² Flexible 2x 1 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.75 ... 2.5 mm² |
Connecting Capacity Main Circuit | Flexible with Ferrule 1x 1 ... 6 mm² Flexible with Ferrule 2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1x 1 ... 6 mm² Flexible with Insulated Ferrule 2x 1 ... 1.5 mm² Flexible 1x 1 ... 6 mm² Flexible 2x 1 ... 4 mm² Rigid 1x 1 ... 10 mm² Rigid 2x 1 ... 4 mm² |
Electrical Durability | AC-1 (NO) 150000 cycle AC-3 (NO) 150000 cycle AC-7a (NO) 150000 cycle AC-7b (NO) 150000 cycle |
Mechanical Durability | 1000000 cycle |
Pollution Degree | 3 |
Rated Frequency (f) | Control Circuit DC Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit 400 Hz Main Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz |
Rated Operational Current AC-7a (Ie) | (NO) 20 A |
Rated Operational Current AC-7b (Ie) | (230 V) Single Phase, NO 9 A |
Rated Operational Power AC-1 (Pe) | (230 V) Single Phase, NO 4.6 kW |
Rated Operational Power AC-7a (Pe) | (230 V) Single Phase, NO 4.6 kW |
Rated Operational Power AC-7b (Pe) | (230 V) Single Phase, NO 1.3 kW |
Recommended Screw Driver | Control Circuit Pozidriv 1 Main Circuit Pozidriv 1 |
Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC/EN 61095 |
Tightening Torque | Control Circuit 0.9 N·m Main Circuit 1.2 N·m |
Wire Stripping Length | Control Circuit 7 mm Main Circuit 10 mm |
TECHNICAL UL/CSA | |
Connecting Capacity Control Circuit UL/CSA | Solid 16-10 AWG Stranded 16-10 AWG |
Connecting Capacity Main Circuit UL/CSA | Solid 14-8 AWG Stranded 14-8 AWG |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Single Phase, NO 1 Hp |
Maximum Operating Voltage UL/CSA | Main Circuit 240 V AC |
Tightening Torque UL/CSA | Control Circuit 8 in·lb Main Circuit 11 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Maximum Operating Altitude Permissible | 2000 m |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 15g |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 3707565 |
E-Number (Sweden) | 3210556 |
EClass | V11.0 : 27142308 |
ETIM 5 | EC001653 - Installation contactor for distribution board |
ETIM 6 | EC001653 - Installation contactor for distribution board |
ETIM 7 | EC001653 - Installation contactor for distribution board |
IDEA Granular Category Code (IGCC) | 4759 >> Installation contactor for distribution board |
Object Classification Code | Q |
UNSPSC | 39121529 |
OTHER | |
Ambient Air Temperature | Operation -25 ... +55 °C Storage -40 ... +80 °C |
Degree Of Protection | IP20 |
Number Of Main Contacts NO | 2 |
Number Of Poles | 2 |
Product Net Width | 18 |
Rated Control Circuit Voltage (Uc) | 230 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kilovolt |
Rated Operational Current AC-1 (Ie) | (NO) 20 ampere |
Rated Operational Current AC-3 (Ie) | (230 V) Single Phase, NO 9 A |
Rated Operational Power AC-3 (Pe) | (230 V) Single Phase, NO 1.3 kW |
Rated Operational Voltage | Main Circuit 220 V DC Main Circuit 250 V AC |
Width In Number Of Modular Spacings | 1 |
Write Your Own Review