Loading...
*All information are subjected to changes without prior notice.

1SBL351074R8011 - AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor

ABB
SKU
AB_1SBL351074R8011
Model
AX50-30-11-80
SGD $107.13 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100

Short description of AX50 30 11 80

Catalog No: 1SBL351074R8011
AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
Country of Origin
Bulgaria (BG)
-
+

UOM: Piece

In stock
In Stock 42
Backorder Leadtime: 5 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
MAIN SPECIFICATION
ABB Global IDABB1SBL351074R8011
Business Area (Master Data) NameElectrification
Catalog DescriptionAX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
Division (Master Data) NameSmart Power
EAN3471522404800
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 volt
SKU ID1SBL351074R8011
TECHNICAL
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 1 s -empty- A
Terminal TypeScrew Terminals
TECHNICAL UL/CSA
General Use Rating UL/CSA(600 V AC) 80 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 Hp
(240 V AC) Single Phase 10 Hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 35 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible3000 m
RoHS StatusFollowing EU Directive 2002/95/EC August 18, 2005 and amendment
CLASSIFICATIONS
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
IDEA Granular Category Code (IGCC)4755 >> Contactors
Object Classification CodeQ
UNSPSC39121529
OTHER
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Degree Of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Number Of Auxiliary Contacts NC1
Number Of Auxiliary Contacts NO1
Number Of Main Contacts NO3
Product Net Width82
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Rated Impulse Withstand Voltage (Uimp)6 kilovolt
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 100 ampere
(690 V) 70 °C 70 ampere
(220 / 240 V) 55 °C 85 ampere
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 53 A
(380 / 400 V) 55 °C 50 A
(415 V) 55 °C 50 A
(440 V) 55 °C 45 A
(500 V) 55 °C 45 A
(690 V) 55 °C 35 A
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 15 kW
(380 / 400 V) 22 kW
(415 V) 25 kW
(440 V) 25 kW
(500 V) 30 kW
(690 V) 30 kW
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Write Your Own Review
You're reviewing:1SBL351074R8011 - AX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
Your Rating