GJL1211501R8005 - B6-22-00-85 Mini Contactor 380-415V 40-450Hz
ABB
SKU
AB_GJL1211501R8005
Model
B6-22-00-85
SGD $20.27 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of B6 22 00 85
Catalog No: GJL1211501R8005
B6-22-00-85 Mini Contactor 380-415V 40-450Hz
B6-22-00-85 Mini Contactor 380-415V 40-450Hz
Country of Origin
Germany (DE)
The B6-22-00 mini contactor is a compact 4 pole contactor with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB.BBCGJL1211501R8005 |
Business Area (Master Data) Name | Electrification |
Catalog Description | B6-22-00-85 Mini Contactor 380-415V 40-450Hz |
Division (Master Data) Name | Smart Power |
EAN | 4013614189272 |
Mini Contactor Type | Mini Contactor |
Rated Insulation Voltage (Ui) | 690 volt acc. to UL/CSA 600 volt |
SKU ID | GJL1211501R8005 |
TECHNICAL | |
Coil Operating Limits | (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour (AC-15) 360 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-13) 360 cycles per hour (DC-3) 600 cycles per hour |
Mechanical Durability | 10000000 cycle |
Mounting On DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
Rated Frequency (f) | Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A |
Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 |
Tightening Torque | Auxiliary Circuit 0.8 ... 1.1 N·m Control Circuit 0.8 ... 1.1 N·m Main Circuit 0.8 ... 1.1 N·m |
Wire Stripping Length | Auxiliary Circuit 9 mm Main Circuit 9 mm |
TECHNICAL UL/CSA | |
Connecting Capacity Auxiliary Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
Full Load Amps Motor Use | (115 V AC) Single Phase 5.8 A (200 V AC) Three Phase 4.8 A (220 ... 240 V AC) Three Phase 6.8 A (230 V AC) Single Phase 4.9 A (440 ... 480 V AC) Three Phase 4.8 A (550 ... 600 V AC) Three Phase 1.7 A |
General Use Rating UL/CSA | (300 V AC) 12 A |
Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.25 Hp (200 V AC) Three Phase 1 Hp (220 ... 240 V AC) Three Phase 2 Hp (230 V AC) Single Phase 0.5 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 1 Hp |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Tightening Torque UL/CSA | Auxiliary Circuit 7 in·lb Control Circuit 7 in·lb Main Circuit 7 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Maximum Operating Altitude Permissible | 2000 m |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 15g |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5g / 5 ... 150 Hz |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
EClass | V11.0 : 27371003 |
ETIM 4 | EC000066 - Magnet contactor, AC-switching |
ETIM 5 | EC000066 - Magnet contactor, AC-switching |
ETIM 6 | EC000066 - Power contactor, AC switching |
ETIM 7 | EC000066 - Power contactor, AC switching |
Object Classification Code | Q |
UNSPSC | 39121529 |
OTHER | |
Ambient Air Temperature | Operation -20 ... +55 °C Storage -40 ... +80 °C |
Degree Of Protection | Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20 |
Number Of Main Contacts NC | 2 |
Number Of Main Contacts NO | 2 |
Number Of Poles | 4 |
Product Net Width | 52.5 |
Rated Control Circuit Voltage (Uc) | 380 ... 415 V AC |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kilovolt Main Circuit 6 kilovolt |
Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 ampere (220 / 240 V) 55 °C 16 ampere (380 / 440 V) 40 °C 20 ampere (380 / 440 V) 55 °C 16 ampere (690 V) 40 °C 6 ampere (690 V) 55 °C 6 ampere |
Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NC 3 kW (690 V) Three Phase, NO 3 kW |
Rated Operational Voltage | Main Circuit 690 V AC Main Circuit 220 V DC |
Write Your Own Review