Loading...
*All information are subjected to changes without prior notice.

2CCS881001R0104 - S801C-C10 High Performance MCB

ABB
SKU
AB_2CCS881001R0104
Model
S801C-C10
SGD $50.87 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100

Short description of S801C C10

Catalog No: 2CCS881001R0104
S801C-C10 High Performance MCB
Country of Origin
China (CN)

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 5 To 7 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

The S801C-C10 is a 1-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 10 A. It is a current limiting device with a maximum breaking capacity of 25kA at 240/415V. It can be used for voltages up to 254/440V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S801C-C10 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S801C-C10 more comfortable. Due to the fast arc extinction of S801C-C10 your application will be secured.
MAIN SPECIFICATION
ABB Global IDABB2CCS881001R0104
Business Area (Master Data) NameElectrification
Catalog DescriptionS801C-C10 High Performance MCB
Division (Master Data) NameSmart Buildings
EAN7612271212124
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 volt
Rated Operation Current10 ampere
SKU ID2CCS881001R0104
TECHNICAL
Accessories AvailableYes
Actuator MarkingI / O
Connecting CapacityRigid 0 ... 50 mm²
Flexible 0 ... 70 mm²
Contact Position IndicationON / OFF / TRIP
Electrical Endurance10000 cycle
Energy Limiting Class3
Frequency (f)50 / 60 Hz
Housing MaterialInsulation group I, RAL 7035
Mechanical Endurance (Nendu)10000 cycle
Mounting On DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionAny
Number Of Protected Poles1
Overvoltage CategoryIV
Pollution Degree3
Power Loss1.5 W
at Rated Operating Conditions per Pole 1.5 W
Product NameHigh Performance MCB
Rated Frequency (f)50...60 Hz
Rated Operational Current (Ie)10 A
Recommended Screw DriverPozidriv 2
Release TypeC
RemarksConnection from top and bottom
Connecting with CU only
IP40 in enclosure with cover
Cage terminal with captive screw
StandardsIEC/EN 60947-2
IEC/EN 60898-1
UL 1077
Terminal TypeScrew Terminals
Tightening Torque3.5 N·m
31 in·lb
TECHNICAL UL/CSA
Interrupting Rating Acc. To UL1077(240 V AC) 20 kA
(347 V AC) 10 kA
(125 V DC) 10 kA
DIMENSIONS
Built-In Depth (t2)82.5 mm
Product Net Length27 mm
ORDERING
Minimum Order Quantity1 piece
Selling Unit Of Measurepiece
ENVIRONMENTAL
Ambient Temperature-25...60 °C
Environmental ConditionsDamp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle
Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96%
Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100%
Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C
Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
Reference Ambient Air Temperatureacc. to IEC60947-2 30 °C
acc. to EN60898-1 30 °C
Resistance To Shock Acc. To IEC 60068-2-275 g
30 ms
Resistance To Vibrations Acc. To IEC 60068-2-62 - 13.2 Hz / 1mm
13.2 - 100Hz / 0.7g
with load 100% x Ie
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
CN885362020
EPLAN Catalog TreeElectrical engineering / Protection devices / General
ETIM 6EC000042 - Miniature circuit breaker (MCB)
ETIM 7EC000042 - Miniature circuit breaker (MCB)
ETIM 8EC000042 - Miniature circuit breaker (MCB)
Object Classification CodeF
WEEE B2C / B2BBusiness To Business
OTHER
Ambient Air TemperatureOperation -25...60 °C
Degree Of ProtectionIP20
Input Voltage TypeAC/DC
Number Of Poles1
Operational VoltageMaximum 230/400 V AC
Minimum 12 V AC
Product Net Width27
Rated Conditional Short-Circuit Current (Inc)(230 V) 25 kA
(400 V) 25 kA
Rated Current (In)10 A
Rated Impulse Withstand Voltage (Uimp)8 kilovolt
Rated Operational Voltage254/440 V AC
125 V DC
acc. to IEC 60898-1 440 V
Rated Service Short-Circuit Breaking Capacity (Ics)(240 / 415 V AC) 18 kA
(254 / 440 V AC) 10 kA
(125 V DC) 10 kA
Rated Short-Circuit Capacity (Icn)(400 V) 15 kA
(230 V) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(240 / 415 V AC) 25 kA
(254 / 440 V AC) 15 kA
(125 V DC) 10 kA
(230 V) 25 kA
(400 V) 25 kA
Rated Voltage (Ur)440 V
Tripping CharacteristicC
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Width In Number Of Modular Spacings4
Write Your Own Review
You're reviewing:2CCS881001R0104 - S801C-C10 High Performance MCB
Your Rating