2CCS881001R0104 - S801C-C10 High Performance MCB
ABB
SKU
AB_2CCS881001R0104
Model
S801C-C10
SGD $50.87 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of S801C C10
Catalog No: 2CCS881001R0104
S801C-C10 High Performance MCB
S801C-C10 High Performance MCB
Country of Origin
China (CN)
The S801C-C10 is a 1-pole High Performance Circuit breaker with C-characteristic, with cage terminal and a rated current of 10 A. It is a current limiting device with a maximum breaking capacity of 25kA at 240/415V. It can be used for voltages up to 254/440V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S801C-C10 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S801C-C10 more comfortable. Due to the fast arc extinction of S801C-C10 your application will be secured.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB2CCS881001R0104 |
Business Area (Master Data) Name | Electrification |
Catalog Description | S801C-C10 High Performance MCB |
Division (Master Data) Name | Smart Buildings |
EAN | 7612271212124 |
Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 volt |
Rated Operation Current | 10 ampere |
SKU ID | 2CCS881001R0104 |
TECHNICAL | |
Accessories Available | Yes |
Actuator Marking | I / O |
Connecting Capacity | Rigid 0 ... 50 mm² Flexible 0 ... 70 mm² |
Contact Position Indication | ON / OFF / TRIP |
Electrical Endurance | 10000 cycle |
Energy Limiting Class | 3 |
Frequency (f) | 50 / 60 Hz |
Housing Material | Insulation group I, RAL 7035 |
Mechanical Endurance (Nendu) | 10000 cycle |
Mounting On DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting Position | Any |
Number Of Protected Poles | 1 |
Overvoltage Category | IV |
Pollution Degree | 3 |
Power Loss | 1.5 W at Rated Operating Conditions per Pole 1.5 W |
Product Name | High Performance MCB |
Rated Frequency (f) | 50...60 Hz |
Rated Operational Current (Ie) | 10 A |
Recommended Screw Driver | Pozidriv 2 |
Release Type | C |
Remarks | Connection from top and bottom Connecting with CU only IP40 in enclosure with cover Cage terminal with captive screw |
Standards | IEC/EN 60947-2 IEC/EN 60898-1 UL 1077 |
Terminal Type | Screw Terminals |
Tightening Torque | 3.5 N·m 31 in·lb |
TECHNICAL UL/CSA | |
Interrupting Rating Acc. To UL1077 | (240 V AC) 20 kA (347 V AC) 10 kA (125 V DC) 10 kA |
DIMENSIONS | |
Built-In Depth (t2) | 82.5 mm |
Product Net Length | 27 mm |
ORDERING | |
Minimum Order Quantity | 1 piece |
Selling Unit Of Measure | piece |
ENVIRONMENTAL | |
Ambient Temperature | -25...60 °C |
Environmental Conditions | Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96% Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100% Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C |
Reference Ambient Air Temperature | acc. to IEC60947-2 30 °C acc. to EN60898-1 30 °C |
Resistance To Shock Acc. To IEC 60068-2-27 | 5 g 30 ms |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 2 - 13.2 Hz / 1mm 13.2 - 100Hz / 0.7g with load 100% x Ie |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
CN8 | 85362020 |
EPLAN Catalog Tree | Electrical engineering / Protection devices / General |
ETIM 6 | EC000042 - Miniature circuit breaker (MCB) |
ETIM 7 | EC000042 - Miniature circuit breaker (MCB) |
ETIM 8 | EC000042 - Miniature circuit breaker (MCB) |
Object Classification Code | F |
WEEE B2C / B2B | Business To Business |
OTHER | |
Ambient Air Temperature | Operation -25...60 °C |
Degree Of Protection | IP20 |
Input Voltage Type | AC/DC |
Number Of Poles | 1 |
Operational Voltage | Maximum 230/400 V AC Minimum 12 V AC |
Product Net Width | 27 |
Rated Conditional Short-Circuit Current (Inc) | (230 V) 25 kA (400 V) 25 kA |
Rated Current (In) | 10 A |
Rated Impulse Withstand Voltage (Uimp) | 8 kilovolt |
Rated Operational Voltage | 254/440 V AC 125 V DC acc. to IEC 60898-1 440 V |
Rated Service Short-Circuit Breaking Capacity (Ics) | (240 / 415 V AC) 18 kA (254 / 440 V AC) 10 kA (125 V DC) 10 kA |
Rated Short-Circuit Capacity (Icn) | (400 V) 15 kA (230 V) 15 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (240 / 415 V AC) 25 kA (254 / 440 V AC) 15 kA (125 V DC) 10 kA (230 V) 25 kA (400 V) 25 kA |
Rated Voltage (Ur) | 440 V |
Tripping Characteristic | C |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Width In Number Of Modular Spacings | 4 |
Write Your Own Review