
1SVR730884R3300 - CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC
ABB
SKU
AB_1SVR730884R3300
Model
CM-MPS.41S
SGD $248.36 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of CM MPS.41S
Catalog No: 1SVR730884R3300
CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC
CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC
Country of Origin
Germany (DE)
The CM-MPS.41S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 300-500 V AC 50/60 Hz and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. This relay monitors all phase parameters such as over/undervoltage, phase unbalance and phase failure. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SVR730884R3300 |
Business Area (Master Data) Name | Electrification |
Catalog Description | CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC |
Division (Master Data) Name | Smart Power |
EAN | 4016779851862 |
Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 600 volt Output Circuit 1 / Output Circuit 2 300 volt |
SKU ID | 1SVR730884R3300 |
TECHNICAL | |
Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² Flexible with Ferrule 2x 0.5 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² Flexible 1x 0.5 ... 2.5 mm² Flexible 2x 0.5 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.5 ... 2.5 mm² |
Electrical Durability | AC-12 100000 cycle |
Mechanical Durability | 30000000 cycle |
Minimum Switching Capacity | 24 V 10 mA |
Mounting On DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting Position | Any |
Overvoltage Category | III |
Pollution Degree | 3 |
Rated Frequency (f) | Supply Circuit 50/60 Hz |
Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
Recommended Screw Driver | Pozidriv 1 4.5 0.8 x 4 |
Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A Output Circuit NO - F Type Fuses 10 A |
Standards | CAN/CSA C22.2 No.14 IEC/EN 63000 IEC/EN 60255-27 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508 |
Terminal Type | Screw Terminals |
Tightening Torque | 0.6 ... 0.8 N·m |
Wire Stripping Length | 8 mm |
TECHNICAL UL/CSA | |
Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG Flexible 2x 18-16 AWG Rigid 1x 20-12 AWG Rigid 2x 20-14 AWG |
Contact Rating UL/CSA | B300 |
Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
Tightening Torque UL/CSA | 7.08 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 2712278 |
E-Number (Sweden) | 3860587 |
EClass | V11.0 : 27371803 |
ETIM 4 | EC001441 - Phase monitoring relay |
ETIM 5 | EC001441 - Phase monitoring relay |
ETIM 6 | EC001441 - Phase monitoring relay |
ETIM 7 | EC001441 - Phase monitoring relay |
Object Classification Code | B |
UNSPSC | 39121536 |
OTHER | |
Ambient Air Temperature | Operation -25 ... +60 °C Storage -40 ... +85 °C |
Degree Of Protection | Housing IP50 Terminals IP20 |
Function | Phase failure detection Phase sequence monitoring Over- and undervoltage monitoring Phase unbalance detection |
Measuring Range | (L-L) 300 ... 500 V AC |
Output | 2 c/o (SPDT) contacts |
Product Net Width | 22.5 |
Rated Control Supply Voltage (Us) | (L-L) 300 ... 500 V AC |
Rated Impulse Withstand Voltage (Uimp) | Input Circuit 6 kilovolt Output Circuit 4 kilovolt |
Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
Time Range | 200 ms start-up delay 0 s or 0.1 ... 30 s tripping delay (ON or OFF) |
Write Your Own Review