CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC

ABB
SKU
AB_1SVR730884R3300
Model
CM-MPS.41S
SGD $250.94

Short description of CM MPS.41S

CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC
Country of Origin
Germany (DE)
-
+

UOM: Piece

In stock
In Stock 4
Backorder Leadtime: 2 To 4 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
The CM-MPS.41S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 300-500 V AC 50/60 Hz and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. This relay monitors all phase parameters such as over/undervoltage, phase unbalance and phase failure. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.
MAIN SPECIFICATION
ABB Global IDABB1SVR730884R3300
Business Area (Master Data) NameElectrification
Catalog DescriptionCM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC
Division (Master Data) NameSmart Power
EAN4016779851862
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 volt
Output Circuit 1 / Output Circuit 2 300 volt
SKU ID1SVR730884R3300
TECHNICAL
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Electrical DurabilityAC-12 100000 cycle
Mechanical Durability30000000 cycle
Minimum Switching Capacity24 V
10 mA
Mounting On DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionAny
Overvoltage CategoryIII
Pollution Degree3
Rated Frequency (f)Supply Circuit 50/60 Hz
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Recommended Screw DriverPozidriv 1
4.5
0.8 x 4
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Terminal TypeScrew Terminals
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
TECHNICAL UL/CSA
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Contact Rating UL/CSAB300
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Tightening Torque UL/CSA7.08 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
E-Number (Finland)2712278
E-Number (Sweden)3860587
EClassV11.0 : 27371803
ETIM 4EC001441 - Phase monitoring relay
ETIM 5EC001441 - Phase monitoring relay
ETIM 6EC001441 - Phase monitoring relay
ETIM 7EC001441 - Phase monitoring relay
Object Classification CodeB
UNSPSC39121536
OTHER
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Degree Of ProtectionHousing IP50
Terminals IP20
FunctionPhase failure detection
Phase sequence monitoring
Over- and undervoltage monitoring
Phase unbalance detection
Measuring Range(L-L) 300 ... 500 V AC
Output2 c/o (SPDT) contacts
Product Net Width22.5
Rated Control Supply Voltage (Us)(L-L) 300 ... 500 V AC
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kilovolt
Output Circuit 4 kilovolt
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Time Range200 ms start-up delay
0 s or 0.1 ... 30 s tripping delay (ON or OFF)
Write Your Own Review