1SDA067037R1 - XT2N 160 TMA 63-630 4p F F
ABB
SKU
AB_1SDA067037R1
Model
XT2N-160-TMA-63-630-4p-F-F
SGD $287.62 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of XT2N 160 TMA 63 630 4p F F
Catalog No: 1SDA067037R1
XT2N 160 TMA 63-630 4p F F
XT2N 160 TMA 63-630 4p F F
Country of Origin
Italy (IT)
C.BREAKER TMAX XT2N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 63 I3=315...630 A
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SDA067037R1 |
Business Area (Master Data) Name | Electrification |
Catalog Description | XT2N 160 TMA 63-630 4p F F |
Division (Master Data) Name | Smart Power |
EAN | 8015644009434 |
Rated Insulation Voltage (Ui) | 1000 volt |
SKU ID | 1SDA067037R1 |
TECHNICAL | |
Circuit Breaker Type To Be Associated | Power Distribution |
Current Type | AC/DC |
Electrical Durability | 120 cycles per hour 8000 cycle |
Mechanical Durability | Nr. Operations 240 cycles per hour Nr. Operations 25000 cycle |
Opening Time | CB with SOR 15 ms CB with UVR 15 ms |
Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 4.85 W |
Product Name | Moulded Case Circuit Breaker |
Product Type | CB |
Rated Frequency (f) | 50 / 60 Hz |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 300…630 A |
Rated Uninterrupted Current (Iu) | 160 A |
Release Type | TM |
Standards | IEC |
Sub-type | XT2 |
Terminal Connection Type | Fixed Circuit-Breakers |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
CLASSIFICATIONS | |
ETIM 4 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 5 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 6 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q |
UNSPSC | 39120000 |
OTHER | |
Number Of Poles | 4 |
Product Net Width | 120 |
Rated Current (In) | 63 A |
Rated Impulse Withstand Voltage (Uimp) | 8 kilovolt |
Rated Operational Voltage | 690 V AC 500 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA |
Rated Voltage (Ur) | 690 V |
Release | TMA |
Setting Range | 44.1...63 A |
Short-Circuit Performance Level | N |
Version | F |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |