1SAX351001R1101 - EF146-150 Electronic Overload Relay
ABB
SKU
AB_1SAX351001R1101
Model
EF146-150
SGD $390.53 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of EF146 150
Catalog No: 1SAX351001R1101
EF146-150 Electronic Overload Relay
EF146-150 Electronic Overload Relay
Country of Origin
China (CN)
The EF146 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the contactors. The EF65, EF96 and EF146 have ATEX and IECEx certification 1)1) ATEX is valid for products produced from week 42, 2014.IECEx is valid for products produced from week 15, 2017.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SAX351001R1101 |
Business Area (Master Data) Name | Electrification |
Catalog Description | EF146-150 Electronic Overload Relay 54-150 A, Trip class adjustable |
Division (Master Data) Name | Smart Power |
EAN | 4013614442230 |
Rated Insulation Voltage (Ui) | 1000 volt |
Rated Operation Current | 150 ampere |
SKU ID | 1SAX351001R1101 |
TECHNICAL | |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Ferrule 1x 10 ... 70 mm² Flexible with Ferrule 2x 10 ... 35 mm² Flexible with Insulated Ferrule 1x 10 ... 70 mm² Flexible with Insulated Ferrule 2x 2 ... 35 mm² Flexible 1x 10 ... 70 mm² Flexible 2x 10 ... 35 mm² Rigid 1x 10 ... 95 mm² Rigid 2x 10 ... 35 mm² |
Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit NC 6 A Auxiliary Circuit NO 6 A |
Mounting Position | Position 1 to 6 |
Number Of Protected Poles | 3 |
Pollution Degree | 3 |
Power Loss | at Rated Operating Conditions per Pole 0.204 W |
Rated Frequency (f) | Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz |
Rated Operational Current (Ie) | 150 A |
Rated Operational Current AC-15 (Ie) | (240 V) NC 3 A (240 V) NO 3 A (400 V) NC 1.1 A (400 V) NO 1.1 A (500 V) NC 0.75 A (500 V) NO 0.75 A |
Rated Operational Current DC-13 (Ie) | (125 V) NC 0.55 A (125 V) NO 0.5 A (24 V) NC 1.5 A (24 V) NO 1.5 A (250 V) NC 0.27 A (250 V) NO 0.27 A (60 V) NC 0.55 A (60 V) NO 0.55 A |
Recommended Screw Driver | Auxiliary Circuit Pozidriv 2 Main Circuit Hexagon 4 |
Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 |
Tightening Torque | Auxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 10 N·m |
Wire Stripping Length | Auxiliary Circuit 9 mm Main Circuit 20 mm |
TECHNICAL UL/CSA | |
Ampere Rating UL/CSA | 150 A |
Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG |
Connecting Capacity Main Circuit UL/CSA | Flexible 1x 6-00 AWG Flexible 2x 6-2 AWG Stranded 2x 6-2 AWG Stranded 1x 6-00 AWG |
Contact Rating UL/CSA | (NC:) B600 (NC:) Q600 (NO:) B600 (NO:) Q600 |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Tightening Torque UL/CSA | Auxiliary Circuit 7 ... 1 in·lb Main Circuit 70 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Ambient Air Temperature Compensation | Yes |
Maximum Operating Altitude Permissible | 2000 m |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 25g |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5g / 3 ... 150 Hz |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 3706582 |
E-Number (Sweden) | 3210247 |
EClass | V11.0 : 27371502 |
ETIM 4 | EC001080 - Electronic overload relay |
ETIM 5 | EC001080 - Electronic overload relay |
ETIM 6 | EC001080 - Electronic overload relay |
ETIM 7 | EC001080 - Electronic overload relay |
IDEA Granular Category Code (IGCC) | 5364 >> Overload relay |
Object Classification Code | F |
UNSPSC | 39121520 |
OTHER | |
Ambient Air Temperature | Operation -25 ... +70 °C Operation Compensated -25 ... +70 °C Storage -50 ... +85 °C |
Degree Of Protection | Housing IP20 Main Circuit Terminals IP10 |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Number Of Poles | 3 |
Product Net Width | 89.05 |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kilovolt Main Circuit 8 kilovolt |
Rated Operational Current AC-3 (Ie) | 150 A |
Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC Main Circuit 1000 V AC |
Setting Range | 54 ... 150 A |
Suitable For | AF116 AF140 AF146 |
Write Your Own Review