MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS116/MS132/MS165 range.
MAIN SPECIFICATION
ABB Global IDABB1SAM451000R1017
Business Area (Master Data) NameElectrification
Catalog DescriptionMS165-65 Manual motor starter Trip class 10, 52 - 65 A
Division (Master Data) NameSmart Power
EAN4013614486111
Rated Insulation Voltage (Ui)1000 volt
Rated Operation Current65 ampere
SKU ID1SAM451000R1017
TECHNICAL
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Contact Position IndicationON / OFF / TRIP
Conventional Free-air Thermal Current (Ith)Main Circuit 65 A
Electrical Durability25000 cycle
Mechanical Durability50000 cycle
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Mounting On DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionPosition 1 to 6
Pollution Degree3
Power Lossat Rated Operating Conditions per Pole 5.14 W
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Instantaneous Short-Circuit Current Setting (Ii)975 A
Rated Operational Current (Ie)65 A
Rated Operational Current AC-3e (Ie)65 A
Rated Operational Current DC-5 (Ie)65 A
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 30 kW
Recommended Screw DriverPozidriv 2
StandardsCSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Terminal TypeScrew Terminals
Tightening TorqueMain Circuit 4 N·m
Wire Stripping LengthMain Circuit 16 mm
TECHNICAL UL/CSA
Ampere Rating UL/CSA65 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Full Load Amps Motor Use(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
General Use Rating UL/CSA(600 V AC) 65 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
Locked Rotor Amps(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Tightening Torque UL/CSAMain Circuit 35 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance To Shock Acc. To IEC 60068-2-2711 ms Pulse 25g
Resistance To Vibrations Acc. To IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
E-Number (Finland)3707290
E-Number (Sweden)3110057
EClassV11.0 : 27370401
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
ETIM 7EC000074 - Motor protection circuit-breaker
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Object Classification CodeF
UNSPSC39121521
OTHER
Actuator TypeRotary Handle
Ambient Air TemperatureOperation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Degree Of ProtectionHousing IP20
Main Circuit Terminals IP10
Number Of Poles3
Product Net Width55
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kilovolt
Rated Operational Current AC-3 (Ie)65 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 30 kW
Rated Operational VoltageMain Circuit 690 V AC
Main Circuit 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
Setting Range52 ... 65 A