1SAM250000R1014 - MS116-25 Manual Motor Starter

ABB
SKU
AB_1SAM250000R1014
Model
MS116-25
SGD $72.55 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100

Short description of MS116 25

Catalog No: 1SAM250000R1014
MS116-25 Manual Motor Starter
Country of Origin
Germany (DE)
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 5 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

The MS116-25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
MAIN SPECIFICATION
ABB Global IDABB1SAM250000R1014
Business Area (Master Data) NameElectrification
Catalog DescriptionMS116-25 Manual Motor Starter Trip class 10A, 20 ... 25 A
Division (Master Data) NameSmart Power
EAN4013614405662
Rated Insulation Voltage (Ui)690 volt
Rated Operation Current25 ampere
SKU ID1SAM250000R1014
TECHNICAL
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Contact Position IndicationON / OFF
Conventional Free-air Thermal Current (Ith)Main Circuit 25 A
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Mounting On DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionPosition 1 to 6
Pollution Degree3
Power Lossat Rated Operating Conditions per Pole 1.8 W
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Instantaneous Short-Circuit Current Setting (Ii)375 A
Rated Operational Current (Ie)25 A
Rated Operational Current AC-3e (Ie)25 A
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 11 kW
Recommended Screw DriverPozidriv 2
StandardsIEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Terminal TypeScrew Terminals
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
TECHNICAL UL/CSA
Ampere Rating UL/CSA25 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Full Load Amps Motor Use(200 V AC) Three Phase 17.5 A
(208 V AC) Three Phase 24.2 A
(220 ... 240 V AC) Three Phase 22 A
(440 ... 480 V AC) Three Phase 21 A
(550 ... 600 V AC) Three Phase 22 A
General Use Rating UL/CSA(600 V AC) 25 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 5 Hp
(208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 7.5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
Locked Rotor Amps(200 V AC) Three Phase 105.8 A
(208 V AC) Three Phase 140 A
(220 ... 240 V AC) Three Phase 127 A
(440 ... 480 V AC) Three Phase 116 A
(550 ... 600 V AC) Three Phase 116 A
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Tightening Torque UL/CSAMain Circuit 18 in·lb
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance To Shock Acc. To IEC 60068-2-2711 ms Pulse 25g
Resistance To Vibrations Acc. To IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
E-Number (Finland)3705874
E-Number (Sweden)3111952
EClassV11.0 : 27370401
ETIM 4EC000074 - Motor protective circuit-breaker
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
ETIM 7EC000074 - Motor protection circuit-breaker
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Object Classification CodeF
UNSPSC39121521
OTHER
Actuator TypeRotary Handle
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Degree Of ProtectionHousing IP20
Main Circuit Terminals IP10
Number Of Poles3
Product Net Width45
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kilovolt
Rated Operational Current AC-3 (Ie)25 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 11 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 10 kA
(400 V AC) 10 kA
(440 V AC) 3 kA
(500 V AC) 3 kA
(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 16 kA
(400 V AC) 16 kA
(440 V AC) 15 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
Setting Range20 ... 25 A