Short description of AA1 400
Catalog No: 1SAM201910R1004
AA1-400 Shunt Trip
AA1-400 Shunt Trip
Country of Origin
Germany (DE)
AA1-400 Shunt Trip 350-415V
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SAM201910R1004 |
Business Area (Master Data) Name | Electrification |
Catalog Description | AA1-400 Shunt Trip 350-415V |
Division (Master Data) Name | Smart Power |
EAN | 4013614343360 |
Rated Insulation Voltage (Ui) | 690 volt |
SKU ID | 1SAM201910R1004 |
TECHNICAL | |
Accessory Group | Electrical |
Accessory Type | Shunt Trip |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
Product Name | Shunt Trip |
Rated Frequency (f) | Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC |
Recommended Screw Driver | Pozidriv 2 |
Remarks | Please consider 15 min OFF-period after 5s ON-period. The mechanical and electrical durability of manual motor starters in combination with UA1/AA1 is reduced. Values are provided on request. |
Standards | CSA 22.2 No. 14 IEC/EN 60947-1 IEC/EN 60947-4-1 UL 508 UL 60947-1 UL 60947-4-1 |
Suitable For Product Class | Manual Motor Starter |
Terminal Type | Screw Terminals |
Tightening Torque | Auxiliary Circuit 0.8 ... 1.2 N·m |
Wire Stripping Length | Auxiliary Circuit 10 mm |
TECHNICAL UL/CSA | |
Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG |
Tightening Torque UL/CSA | Auxiliary Circuit 7 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 15g |
RoHS Status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
CLASSIFICATIONS | |
EClass | V11.0 : 27370418 |
ETIM 4 | EC002498 - Accessories for low-voltage switch technology |
ETIM 5 | EC001023 - Shunt release (for power circuit breaker) |
ETIM 6 | EC001023 - Shunt release (for power circuit breaker) |
ETIM 7 | EC001023 - Shunt release (for power circuit breaker) |
IDEA Granular Category Code (IGCC) | 4879 >> Shunt release (for power circuit breaker) |
Object Classification Code | Q |
UNSPSC | 39121521 |
OTHER | |
Ambient Air Temperature | Operation -25 ... +60 °C Storage -50 ... +80 °C |
Product Net Width | 18 |
Rated Control Supply Voltage (Us) | (50 / 60 Hz) 350 ... 415 V (50 / 60 Hz ON-Period = 5s) 420 ... 500 V (DC ON-Period = 5s) 350 ... 500 V |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kilovolt |
Suitable For | MS116 MS132 MO132 MS165 MO165 |