1SAM201903R1001 - SK1-11 Signaling Contact
ABB
SKU
AB_1SAM201903R1001
Model
SK1-11
SGD $14.65 All prices inclusive of GST
Get 10% OFF, apply code: ABB10OFF
Min. spend $100
Min. spend $100
Short description of SK1 11
Catalog No: 1SAM201903R1001
SK1-11 Signaling Contact
SK1-11 Signaling Contact
Country of Origin
Bulgaria (BG)
Signaling contacts SK1 with screw terminals signal the tripping of the manual motor starter. For SK1 the indication on the device itself is done with a protruding orange button. The contact positions of SK1 need to be manually reset after a tripping event by pushing the orange button. SK1 signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1 are available as normally open or normally closed contacts.
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB1SAM201903R1001 |
Business Area (Master Data) Name | Electrification |
Catalog Description | SK1-11 Signaling Contact 1 NO + 1 NC |
Division (Master Data) Name | Smart Power |
EAN | 4013614320392 |
Rated Insulation Voltage (Ui) | 690 volt |
SKU ID | 1SAM201903R1001 |
TECHNICAL | |
Accessory Group | Electrical |
Accessory Type | Signal Contact |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 1.5 mm² |
Electrical Durability | 100000 cycle |
Mechanical Durability | 100000 cycle |
Product Name | Signaling Contact |
Rated Operational Current AC-15 (Ie) | (24 V) 6 A (240 V) 4 A (690 V) 1 A (380 / 400 V) 3 A |
Rated Operational Current DC-13 (Ie) | (24 V) 2 A (125 V) 0.55 A (250 V) 0.27 A (440 V) 0.15 A (600 V) 0.15 A |
Recommended Screw Driver | M3 Pozidriv 2 |
Standards | CSA 22.2 No. 14 IEC/EN 60947-1 IEC/EN 60947-5-1 UL 508 UL 60947-1 UL 60947-4-1 |
Suitable For Product Class | Manual Motor Starter |
Terminal Type | Screw Terminals |
Tightening Torque | Auxiliary Circuit 0.8 ... 1.2 N·m |
Wire Stripping Length | Auxiliary Circuit 8 mm |
TECHNICAL UL/CSA | |
Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 16-14 AWG Stranded 1/2x 16-14 AWG |
Contact Rating UL/CSA | B600 Q600 |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Tightening Torque UL/CSA | Auxiliary Circuit 7 in·lb |
ORDERING | |
Minimum Order Quantity | 2 piece |
ENVIRONMENTAL | |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 25g |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5g / 3 ... 150 Hz |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 3706020 |
E-Number (Sweden) | 3112011 |
EClass | V11.0 : 27371302 |
ETIM 4 | EC002498 - Accessories for low-voltage switch technology |
ETIM 5 | EC000041 - Auxiliary contact block |
ETIM 6 | EC000041 - Auxiliary contact block |
ETIM 7 | EC000041 - Auxiliary contact block |
IDEA Granular Category Code (IGCC) | 4742 >> Electrical contacts |
Object Classification Code | Q |
UNSPSC | 39121522 |
OTHER | |
Ambient Air Temperature | Operation -25 ... +60 °C Storage -50 ... +80 °C |
Degree Of Protection | IP20 |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Product Net Width | 9 |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kilovolt |
Rated Operational Voltage | 690 V AC 600 V DC Main Circuit 690 V |
Suitable For | MS116 MS132 MO132 MS165 MO165 |
Write Your Own Review