PM5350 Power Monitor
Schneider
SKU
SE_METSEPM5350
Model
METSEPM5350
SGD $896.07
Short description of METSEPM5350
PM5350 POWER METER WITHTHD.ALARMING
Country of Origin
India
PM5350 power monitor.
Label :  PM5350 Monitoring system
-  range :  PowerLogic
-  product name :  PowerLogic PM5350
-  device short name :  PM5350
-  product or component type :  power meter
-  market segment :  , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
-  Range Presentation- 
Label :  PM5350 Monitoring system
-  range :  PowerLogic
-  product name :  PowerLogic PM5350
-  device short name :  PM5350
-  product or component type :  power meter
-  market segment :  , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
-  Range Presentation- 
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 100...300 V DC 85...265 V AC 45...65 Hz |
Contacts Type And Composition | 1 A 5 A |
Control Type | 1P + N 3P 3P + N |
Display Type | backlit LCD |
Measurement Accuracy | current 0.3 % frequency 0.05 % power factor +/- 0.005 voltage 0.3 % |
Mounting Diameter | 4 digital |
Product Or Component Type | power meter |
Communication Port Protocol | JBUS Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds |
Device Short Name | PM5350 |
EAN13 | 3606480284311 |
Power Quality Analysis | total demand distortion total harmonic distortion |
Range | PowerLogic |
Range Name | PM5350 Monitoring system |
Type Of Measurement | active power apparent power current energy frequency phase angle power factor reactive power voltage |
COMPLEMENTARY | |
Analogue Input Type | current 0.05...9 A (impedance <= 0.3 Ohm) |
Analogue Output Number | backlit LCD |
Communication Gateway | 6 lines |
Display Resolution | 6 lines |
Number Of Inputs | 4 digital |
Output Voltage | current 0.05...9 A (impedance <= 0.3 Ohm) |
Product Name | PowerLogic PM5350 |
Time Delay | current 0.3 % frequency 0.05 % power factor +/- 0.005 voltage 0.3 % |
[In] Rated Current | 1 A 5 A |
Accuracy Class | class 0.5 active energy conforming to IEC 61557-12 class 0.5 power conforming to IEC 61557-12 class 0.5S active energy conforming to IEC 62053-22 class 2 reactive energy conforming to IEC 61557-12 class 3 reactive energy conforming to IEC 62053-23 |
Communication Port Support | terminal block: RS485 |
Compatibility Code | PM5350 |
Connections - Terminals | control circuit: screw terminal block2 current transformer: screw terminal block6 Ethernet network: RJ45 connector input/output circuit: screw terminal block6 relay output: screw terminal block4 voltage circuit: screw terminal block4 |
Data Recording | alarms min/max of instantaneous values |
Depth | 44 mm |
Device Application | power monitoring |
Frequency Measurement Range | 45-70 Hz |
Height | 96 mm |
Information Displayed | tariff (4) |
Market Segment | buildings large building cost management: billing: main incomer buildings large building cost management: billing: sub feeder buildings large building cost management: cost allocation: main incomer buildings large building cost management: cost allocation: sub feeder buildings large building network management: sub feeder buildings medium building cost management: billing: main incomer buildings medium building cost management: billing: sub feeder buildings medium building cost management: cost allocation: main incomer buildings medium building cost management: cost allocation: sub feeder buildings medium building network management: main incomer buildings medium building network management: sub feeder buildings multi-site cost management: billing: main incomer buildings multi-site cost management: billing: sub feeder buildings multi-site cost management: cost allocation: main incomer buildings multi-site cost management: cost allocation: sub feeder buildings multi-site network management: sub feeder buildings small building cost management: billing: main incomer buildings small building cost management: billing: sub feeder buildings small building cost management: cost allocation: main incomer buildings small building cost management: cost allocation: sub feeder buildings small building network management: main incomer buildings small building network management: sub feeder data center cost management: billing: main incomer data center cost management: billing: sub feeder data center cost management: cost allocation: main incomer data center cost management: cost allocation: sub feeder data center network management: sub feeder healthcare cost management: billing: main incomer healthcare cost management: billing: sub feeder healthcare cost management: cost allocation: main incomer healthcare cost management: cost allocation: sub feeder healthcare network management: sub feeder industry cost management: billing: main incomer industry cost management: billing: sub feeder industry cost management: cost allocation: main incomer industry cost management: cost allocation: sub feeder industry network management: sub feeder |
Maximum Power Consumption In VA | 9.6 VA |
Measurement Current | 0-1 A 0-5 A |
Measurement Voltage | 20-400 V AC phase to neutral 20-690 V AC phase to phase |
Mounting Mode | flush-mounted |
Net Weight | 0.25 kg |
Network Frequency | 50 Hz 60 Hz |
Number Of Outputs | 2 relay |
Ride-through Time | 100 ms 230 V AC typical 100 ms 415 V AC typical 80 ms 120 V AC typical |
Sampling Rate | 32 samples/cycle |
Type Of Installation | indoor installation |
Width | 96 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -40-85 °C |
Ambient Air Temperature For Storage | -25-70 °C |
Electromagnetic Compatibility | 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 conducted and radiated emissions class A conforming to EN 55011 conducted RF disturbances conforming to IEC 61000-4-6 electrical fast transient/burst immunity test conforming to IEC 61000-4-4 electrostatic discharge conforming to IEC 61000-4-2 immunity to impulse waves conforming to IEC 61000-4-12 limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 limits for harmonic current emissions conforming to IEC 61000-3-2 susceptibility to electromagnetic fields conforming to IEC 61000-4-3 |
IP Degree Of Protection | IP30 back: conforming to IEC 60529 IP51 front face: conforming to IEC 60529 |
Operating Altitude | 0...3000 m |
Overvoltage Category | III |
Pollution Degree | 2 |
Product Certifications | CE cULus |
Relative Humidity | 0-95 % at 50-50 °C |
Standards | IEC 61010-1 |
OTHER | |
Poles Description | 1P + N 3P 3P + N |
[Us] Rated Supply Voltage | 100...300 V DC 85...265 V AC 45...65 Hz |
Write Your Own Review