Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Module XPSAT - Emergency Stop - 24 V DC.

Schneider
SKU
SE_XPSATE5110P
Model
XPSATE5110P

Obsolete

Short description of XPSATE5110P

Safety Modules
Obsolete
*All information are subjected to changes without prior notice.
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSATE
-  safety module application : For emergency stop and switch monitoring
-  function of module : Emergency stop button with 2 NC contacts
-  safety level : Can reach PL d/category 3 time delay safety outputs conforming to EN/ISO 13849-1Can reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1Can reach SILCL 3 instantaneous safety outputs conforming to EN/IEC 62061Can reach SILCL 2 time delay safety outputs conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1 instantaneous safety outputsMTTFd = 134.8 years conforming to EN/ISO 13849-1 instantaneous safety outputsMTTFd = 54.5 years conforming to EN/ISO 13849-1 time delay safety outputsDC > 98.4 conforming to EN/ISO 13849-1 time delay safety outputsPFHd = 6.81E
- 9 1/h conforming to EN/IEC 62061 instantaneous safety outputsPFHd = 1.96E
- 8 1/h conforming to EN/IEC 62061 time delay safety outputs
-  type of start : Configurable
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay instantaneous opening, 2 NO circuit(s), volt
- freeRelay time delay opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 3 solid state outputs
-  [Us] rated supply voltage : 24 V DC-15...10 %
MAIN SPECIFICATIONS
Analogue Input Number24 V DC - 15...10 %
Breaking Capacity1 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Continuous Powercan reach PL d/category 3 time delay safety outputs conforming to EN/ISO 13849-1
can reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1
can reach SILCL 2 time delay safety outputs conforming to EN/IEC 62061
can reach SILCL 3 instantaneous safety outputs conforming to EN/IEC 62061
Product Or Component TypePreventa safety module
Range Of ProductPreventa Safety automation
Thread Type0...30 s
[Uc] Control Circuit Voltage24 V DC
Function Of Moduleemergency stop button with 2 NC contacts
Mounting Support35 mm symmetrical DIN rail
Number Of Additional Circuits3 solid state outputs
Range NamePreventa XPS
Safety Module Applicationfor emergency stop and switch monitoring
Safety Module NameXPSATE
Type Of Startconfigurable
COMPLEMENTARY
Interlocked Device1 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Product Namerelay instantaneous opening, 2 NO circuit(s), volt-free
relay time delay opening, 3 NO circuit(s), volt-free
Time Delay Range0...30 s
Associated Fuse Rating4 A gG for time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A gG for instantaneous outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Connections - Terminalscaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Input Protection Typeinternal, electronic
Local Signalling4 LEDs
Maximum Power Consumption In W8 W
Maximum Response Time On Input Open20 ms
Minimum Output Current10 mA for relay output
Minimum Output Voltage17 V for relay output
Net Weight0.28 kg
Output Thermal Current2.5 A for time delay outputs
5 A for instantaneous outputs
Output Typerelay instantaneous opening, 2 NO circuit(s), volt-free
relay time delay opening, 3 NO circuit(s), volt-free
Safety Reliability DataDC > 98.4 conforming to EN/ISO 13849-1 time delay safety outputs
DC > 99 % conforming to EN/ISO 13849-1 instantaneous safety outputs
MTTFd = 134.8 years conforming to EN/ISO 13849-1 instantaneous safety outputs
MTTFd = 54.5 years conforming to EN/ISO 13849-1 time delay safety outputs
PFHd = 1.96E-8 1/h conforming to EN/IEC 62061 time delay safety outputs
PFHd = 6.81E-9 1/h conforming to EN/IEC 62061 instantaneous safety outputs
Supply Frequency50/60 Hz
Synchronisation Time Between Inputs75 ms
[Ith] Conventional Free Air Thermal Current8 A
[Uimp] Rated Impulse Withstand Voltage4 kV overvoltage category III conforming to DIN VDE 0110 part 1
4 kV overvoltage category III conforming to IEC 60947-5-1
[Ui] Rated Insulation Voltage300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
300 V (pollution degree 2) conforming to IEC 60947-5-1
ENVIRONMENT
Safety Levelcan reach PL d/category 3 time delay safety outputs conforming to EN/ISO 13849-1
can reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1
can reach SILCL 2 time delay safety outputs conforming to EN/IEC 62061
can reach SILCL 3 instantaneous safety outputs conforming to EN/IEC 62061
Ambient Air Temperature For Operation-10-55 °C
Ambient Air Temperature For Storage-25-85 °C
IP Degree Of ProtectionIP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529
Product CertificationsCSA
TÜV
UL
StandardsEN/IEC 60204-1
EN/IEC 60947-5-1
EN/ISO 13850
OTHER
Poles DescriptionPreventa safety module
[Us] Rated Supply Voltage24 V DC - 15...10 %