Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Module Network TM4 1 Profibus DP Slave.

Schneider
SKU
SE_TM4PDPS1
Model
TM4PDPS1
SGD $931.17

Short description of TM4PDPS1

For performance-demanding applications
Country of Origin
Indonesia
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 3 To 5 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
product or component type : Profibus DP communication module
MAIN SPECIFICATIONS
Product Or Component TypeProfibus DP communication module
Communication Port ProtocolProfibus DP V0
Profibus DP V1
Mounting Support plate or panel with fixing kit
top hat type TH35-15 rail conforming to IEC 60715
top hat type TH35-7.5 rail conforming to IEC 60715
Range CompatibilityModicon M241
Modicon M251
Range NameLogic Controller - Modicon M241
COMPLEMENTARY
Current Consumption290 mA at 5 V DC for communication bus
Depth90 mm
Electrical Connectionscrew connector terminal for connecting the functional ground
SUB-D 9 1 female connector for connecting Profibus
Height90 mm
Insulationbetween bus and internal logic at 1000 V DC
Integrated Connection TypeProfibus DP: female SUB-D 9 connector
Local Signalling1 LED (green/red) for communication
1 LED (green/yellow) for power supply
MarkingCE
Net Weight0.1 kg
Power Dissipation In W1.5 W
Product CompatibilityModicon M241 logic controller
Modicon M251 logic controller
Surge Withstand0.5 kV I/O differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
Transmission Rate1.5 Mbit/s for bus length of 200-200 m
187.5 kbit/s for bus length of 1000-1000 m
3...12 Mbit/s for bus length of 100-100 m
500 kbit/s for bus length of 400-400 m
9.6...93.75 kbit/s for bus length of 1200-1200 m
Width25 mm
ENVIRONMENT
Ambient Air Temperature For Operation-10-50 °C vertical installation
-10-55 °C horizontal installation
Ambient Air Temperature For Storage-25-70 °C
Electromagnetic Emissionconducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to EN/IEC 55011
conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to EN/IEC 55011
conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to EN/IEC 55011
conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to EN/IEC 55011
conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to EN/IEC 55011
radiated emissions - test level: 24 dBμV/m QP at 156-165 MHz conforming to Marine specification (LR, ABS, DNV, GL)
radiated emissions - test level: 40 dBμV/m QP class A at 30-230 MHz conforming to EN/IEC 55011
radiated emissions - test level: 47 dBμV/m QP class A at 230-1000 MHz conforming to EN/IEC 55011
radiated emissions - test level: 54 dBμV/m QP at 100-2000 MHz conforming to Marine specification (LR, ABS, DNV, GL)
radiated emissions - test level: 60...54 dBμV/m QP at 30-100 MHz conforming to Marine specification (LR, ABS, DNV, GL)
radiated emissions - test level: 80...50 dμV/m QP at 150-30000 kHz conforming to Marine specification (LR, ABS, DNV, GL)
IP Degree Of ProtectionIP20 with protective cover in place
Operating Altitude0...2000 m
Pollution Degree2
Product CertificationsC-Tick
cULus
Relative Humidity10-95 %, without condensation (in operation)
10-95 %, without condensation (in storage)
Resistance To Conducted Disturbances10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
Resistance To Electromagnetic Fields1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
Resistance To Electrostatic Discharge4 kV on contact conforming to EN/IEC 61000-4-2
6 kV on contact conforming to Marine specification (LR, ABS, DNV, GL)
8 kV in air conforming to EN/IEC 61000-4-2
8 kV in air conforming to Marine specification (LR, ABS, DNV, GL)
Resistance To Fast Transients1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
1.5 kV (I/O) conforming to EN/IEC 61000-4-4
2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
Shock Resistance15 gn for 11 ms
StandardsEIA-485
EN/IEC 61131-2
UL 508
Vibration Resistance0.7 gn at 13.2-100 Hz on panel mounting
1 mm at 5-13.2 Hz on panel mounting
1 mm at 5-13.2 Hz on symmetrical rail
3 gn at 8.7-150 Hz on symmetrical rail
ENVIRONMENTAL
Storage Altitude0-3000 m
OTHER
Poles DescriptionProfibus DP communication module
Write Your Own Review
You're reviewing:Module Network TM4 1 Profibus DP Slave.
Your Rating