Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Analog Input Module, Modicon TM3, 4 / Temperature Inputs (spring) 24 VDC.

Schneider
SKU
SE_TM3TI4G
Model
TM3TI4G
SGD $698.25

Short description of TM3TI4G

Flexible I/O expansion modules for Modicon controllers
Country of Origin
Japan
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range of product : Modicon TM3
-  product or component type : Analog input module
-  range compatibility : Modicon M221Modicon M241Modicon M251Modicon M262
-  analogue input number : 4
-  analogue input type : current 4...20 mA current 0...20 mA voltage 0...10 V voltage
-  10...10 V thermocouple
-  200...1000 °C with thermocouple J thermocouple
-  200...1300 °C with thermocouple K thermocouple 0...1760 °C with thermocouple R thermocouple 0...1760 °C with thermocouple S thermocouple 0...1820 °C with thermocouple B thermocouple
-  200...400 °C with thermocouple T thermocouple
-  200...1300 °C with thermocouple N thermocouple
-  200...800 °C with thermocouple E thermocouple 0...2315 °C with thermocouple CPt 100 temperature probe
-  200...850 °CPt 1000 temperature probe
-  200...600 °C
MAIN SPECIFICATIONS
Analogue Input Number4
Analogue Input Range4
Product Or Component Typeanalog input module
Range Of ProductModicon TM3
Analogue Input Resolution15 bits + sign
16 bits
Mounting Support plate or panel with fixing kit
top hat type TH35-15 rail conforming to IEC 60715
top hat type TH35-7.5 rail conforming to IEC 60715
Range CompatibilityModicon M221
Modicon M241
Modicon M251
Modicon M262
Range NameModicon TM3
COMPLEMENTARY
Analogue Input Type current 0...20 mA
current 4...20 mA
thermocouple - 200...1000 °C with thermocouple J
thermocouple - 200...1300 °C with thermocouple K
thermocouple - 200...1300 °C with thermocouple N
thermocouple - 200...400 °C with thermocouple T
thermocouple - 200...800 °C with thermocouple E
thermocouple 0...1760 °C with thermocouple R
thermocouple 0...1760 °C with thermocouple S
thermocouple 0...1820 °C with thermocouple B
thermocouple 0...2315 °C with thermocouple C
voltage - 10...10 V
voltage 0...10 V
Pt 100 temperature probe - 200...850 °C
Pt 1000 temperature probe - 200...600 °C
Output Voltage current 0...20 mA
current 4...20 mA
thermocouple - 200...1000 °C with thermocouple J
thermocouple - 200...1300 °C with thermocouple K
thermocouple - 200...1300 °C with thermocouple N
thermocouple - 200...400 °C with thermocouple T
thermocouple - 200...800 °C with thermocouple E
thermocouple 0...1760 °C with thermocouple R
thermocouple 0...1760 °C with thermocouple S
thermocouple 0...1820 °C with thermocouple B
thermocouple 0...2315 °C with thermocouple C
voltage - 10...10 V
voltage 0...10 V
Pt 100 temperature probe - 200...850 °C
Pt 1000 temperature probe - 200...600 °C
Absolute Accuracy Error+/- 0.2 % of full scale at 25 °C for analogue input voltage/current
+/- 0.2 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 0.2 % of full scale at 25 °C for thermocouple B 300...1820 °C
+/- 0.2 % of full scale at 25 °C for thermocouple C 0...2315 °C
+/- 0.2 % of full scale at 25 °C for thermocouple E 0...800 °C
+/- 0.2 % of full scale at 25 °C for thermocouple J 0...1000 °C
+/- 0.2 % of full scale at 25 °C for thermocouple K 0...1300 °C
+/- 0.2 % of full scale at 25 °C for thermocouple N 0...1300 °C
+/- 0.2 % of full scale at 25 °C for thermocouple R, S 200...1760 °C
+/- 0.2 % of full scale at 25 °C for thermocouple T 0...400 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C
+/- 6 °C at 25 °C for thermocouple R, S 0...200 °C
Conversion Time10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current
100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe
100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple
Cross Talk<= 1 LSB
Current Consumption35 mA at 24 V DC via external supply
40 mA at 24 V DC via external supply
45 mA at 5 V DC via bus connector
50 mA at 5 V DC via bus connector
Depth70 mm
Electrical Connection10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs
10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs and supply
Height90 mm
Immunity To Microbreaks10 ms
Input Impedance<= 50 Ohm current
>= 1 MOhm temperature probe
>= 1 MOhm thermocouple
>= 1 MOhm voltage
Insulationbetween input and internal logic at 500 V AC
between input and supply at 1500 V AC
Local Signalling1 LED (green) for PWR
LSB Value0.1 °Ctemperature probe
0.1 °Cthermocouple
2.44 mV 0...10 Vvoltage
3.91 µA 4...20 mAcurrent
4.88 µA 0...20 mAcurrent
4.88 mV - 10...10 Vvoltage
MarkingCE
Net Weight0.1 kg
Non-linearity+/- 0.2 %FS
Permissible Continuous Overload13 V, analogue input type: voltage
40 mA, analogue input type: current
Repeat Accuracy+/-0.5 %FS
Sampling Duration10 ms, analogue input type: voltage/current
100 ms, analogue input type: temperature probe
100 ms, analogue input type: thermocouple
100 ms, analogue input type: voltage/current
Supply Voltage Limits20.4-28.8 V
Surge Withstand0.5 kV power supply differential mode conforming to EN/IEC 61000-4-5
1 kV input common mode conforming to EN/IEC 61000-4-5
1 kV power supply common mode conforming to EN/IEC 61000-4-5
Temperature Drift+/- 0.01 %FS/°C
Type Of Cabletwisted shielded pairs cable <30 m for input circuit
Width23.6 mm
ENVIRONMENT
Ambient Air Temperature For Operation-10-35 °C vertical installation
-10-55 °C horizontal installation
Ambient Air Temperature For Storage-25-70 °C
Electromagnetic Emissionradiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011
radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230-1000 MHz conforming to EN/IEC 55011
IP Degree Of ProtectionIP20
Operating Altitude0...2000 m
Pollution Degree2
Relative Humidity10-95 %, without condensation (in operation)
10-95 %, without condensation (in storage)
Resistance To Conducted Disturbances10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Resistance To Electromagnetic Fields1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
Resistance To Electrostatic Discharge4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
Resistance To Fast Transients1 kV (I/O) conforming to EN/IEC 61000-4-4
Resistance To Magnetic Fields30 A/m conforming to EN/IEC 61000-4-8
Shock Resistance15 gn for 11 ms
StandardsEN/IEC 61010-2-201
EN/IEC 61131-2
Vibration Resistance3 gn at 8.4-150 Hz on DIN rail
3.5 mm at 5-8.4 Hz on DIN rail
ENVIRONMENTAL
Storage Altitude0-3000 m
OTHER
Poles Descriptionanalog input module
[Us] Rated Supply Voltage24 V DC
Write Your Own Review
You're reviewing:Analog Input Module, Modicon TM3, 4 / Temperature Inputs (spring) 24 VDC.
Your Rating