DIN rail mount relay, Harmony Solid State Relays, 20A, zeroVoltage switching, input 90…280V AC/DC, output 48...600V AC
Schneider
SKU
SE_SSD1A320M7C1
Model
SSD1A320M7C1
SGD $119.90
Short description of SSD1A320M7C1
This solid state DIN rail mounted relay belongs to the Schneider Electric Harmony solid state relays range. This electrical relay mounts on 35mm DIN rail and comes with a secure mounting latch. This is a 20A power rated relay with relay type configuration and zero voltage switching. This single-phase relay has a IP20 built-in heat sink and a built-in transient overvoltage protection. It is controlled with a 90Vdc/Vac to 280Vdc/Vac input, has a rated load voltage of 48Vac to 600Vac. It also has a LED input voltage status indicator and clip-in legend for easy identification. It weighs 0.298Kg and its dimensions are, 22.5mm wide, 116.6mm deep, 93.2mm high. It is the ideal solution for packaging, plastic molding, textile, and heating furnace applications. This relay conforms to international standards like EN/IEC 60068, IEC 61373, UL 508, CSA C22.2 No 14-13 and certifications like UL and CSA. Besides the existing standard screw connection for input and output, SSD provides more wiring options like the spring or screw pluggable input connectors, and telescopic or clamp cage output terminals.
Country of Origin
Mexico
MAIN | |
---|---|
Range Of Product | Harmony Solid State Relays |
Product Or Component Type | Solid state relay up to 20 A |
Device Short Name | SSD1 |
Number Of Channels | 1 |
Number Of Phases | 1 phase |
Product Configuration Type | Relay configuration |
Mounting Support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
Rated Current | 20 A |
Output Switching Mode | Zero voltage switching |
COMPLEMENTARY | |
Operating Frequency | 47...440 Hz |
Rated Duty | Uninterrupted |
Output Voltage | 48...600 V AC |
Control Circuit Voltage | 90...280 V AC/DC |
Tightening Torque | 1.5...1.7 N.m for control input 13...15 lb.in for control input 1.5...1.7 N.m for load output 13...15 lb.in for load output |
Connections - Terminals | Screw terminals, clamping connection capacity:1...4 mm², AWG 18...AWG 12 for input Screw terminals, clamping connection capacity:1...6 mm², AWG 18...AWG 10 for output |
Dielectric Strength | 4 kV AC for input/output circuit 4 kV AC for input or output to case |
Rated Impulse Withstand Voltage | 6 kV for input/output circuit 6 kV for input or output to case |
Insulation Resistance | 1000 MOhm at 500 V DC |
Local Signalling | for control voltage LED (green) |
Pick-up Voltage | 90 V AC/DC turn-on |
Drop-out Voltage | 5 V AC/DC turn-off |
Input Current Range | 6…10 mA |
Solid State Switching Type | Zero voltage switching |
Load Current | 0.1…20 A |
Transient Overvoltage | 1200 V |
Inrush Current | 300 A at 60 Hz |
Maximum Voltage Drop | <1.3 V on-state |
Motor Controller Rating | 0.37 kW/0.5 hp at 120 V AC 1.12 kW/1.5 hp at 240 V AC 2.24 kW/3 hp at 480 V AC |
Electromagnetic Compatibility | Electrostatic discharge 6 kV criteria A contact discharge conforming to IEC 61000-4-2 Electrostatic discharge 8 kV criteria A air discharge conforming to IEC 61000-4-2 Conducted RF disturbances 10 V, 0.15...80 MHz criteria A level 3 conforming to IEC 61000-4-6 Electrical fast transient/burst immunity test 2 kV, 5/100 kHz criteria B output ports conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test 1 kV, 5/100 kHz criteria B input ports conforming to IEC 61000-4-4 Radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A conforming to IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...2 GHz criteria A conforming to IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test 1 V/m, 2...2.7 GHz criteria A conforming to IEC 61000-4-3 Surge immunity test 1 kV criteria A output ports line to line conforming to IEC 61000-4-5 Surge immunity test 2 kV criteria A output ports line to earth conforming to IEC 61000-4-5 Surge immunity test 1 kV criteria A input ports line to line conforming to IEC 61000-4-5 Surge immunity test 2 kV criteria A input ports line to earth conforming to IEC 61000-4-5 Radiated emission environment B for AC input supply conforming to IEC 60947-4-3 Conducted emission environment A for AC input supply conforming to IEC 60947-4-3 Immunity to microbreaks and voltage drops 30 %, 500 ms criteria A conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops 100 %, 20 ms criteria B conforming to IEC 61000-4-11 |
Device Form Designation | Form 5 semiconductor output DOL contactor |
Maximum I²t For Fusing | 409 A².s for 10 ms 375 A².s for 8.33 ms |
Maximum Leakage Current | 1 mA off-state |
DV/dt | 500 V/µs off-state at maximum rated voltage |
Response Time | 20 ms (turn-on) 30 ms (turn-off) |
Load Power Factor Range | 0.5 with maximum load |
Short Circuit Protection Coordination | Type 1 Type 2 |
Overvoltage Category | III |
Width | 0.89 in (22.5 mm) |
Height | 3.67 in (93.2 mm) |
Depth | 4.59 in (116.5 mm) |
Net Weight | 0.66 lb(US) (0.298 kg) |
Device Presentation | Complete product |
ENVIRONMENT | |
Flammability Rating | V-0 conforming to UL 94 |
Vibration Resistance | 0.75 mm (f = 10…150 Hz) conforming to IEC 60068-2-6 |
Shock Resistance | 50 gn for 11 ms (peak acceleration) , longitudinal position conforming to IEC 60068-2-27 30 gn for 11 ms (peak acceleration) , vertical position conforming to IEC 60068-2-27 |
Pollution Degree | 2 |
Standards | IEC 61373:class B: category 1 IEC 60947-4-3 IEC 62314 IEC 60950-1 CSA C22.2 No 14-13 UL 508 |
IP Degree Of Protection | IP20 |
Ambient Air Temperature For Operation | -40…176 °F (-40…80 °C) |
Ambient Air Temperature For Storage | -40…212 °F (-40…100 °C) |
ORDERING AND SHIPPING DETAILS | |
Category | 22375-INTERFACE MODULE(ABA,R,S) |
Discount Schedule | CP2 |
GTIN | 3606489807832 |
Returnability | No |