Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Harmony, Modular 3-phase Voltage Control Relay, 8 A, 2 CO, 200…240 V AC

Schneider
SKU
SE_RM22TR31
Model
RM22TR31
SGD $163.10

Short description of RM22TR31

3 PHASE VOLTAGE CONTROL RELAY RM22-TR -
Country of Origin
Indonesia
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
three
- Phase Voltage control relay 200…240Vac, 2 C/O.
Label :  Zelio Control
-  range of product :  Zelio Control
-  switching capacity in VA :  2000 VA
-  product or component type :  modular measurement and control relays
-  measurement range :  200...240 V voltage AC
-  relay type :  control relay
-  network number of phases :  3 phases
-  relay name :  RM22TR
-  relay monitored parameters :  phase sequence,phase failure detection,overvoltage and undervoltage detection
-  time delay type :  adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.

-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 

-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
MAIN SPECIFICATIONS
Analogue Input Number200...240 V AC
Contacts Type And Composition2 C/O
Discrete Input Number2 C/O
Product Or Component Type3-phase control relay
Range Of ProductHarmony Control Relays
[Uc] Control Circuit Voltage200...240 V
EAN133606480792182
Measurement Range200...240 V voltage AC
Mounting Support35 mm DIN rail conforming to EN/IEC 60715
Network Number Of Phases3 phases
Range NameZelio Control
Relay Monitored Parametersovervoltage and undervoltage detection
phase failure detection
phase sequence
Relay NameRM22TR
Relay Typecontrol relay
Time Delay Typeadjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Utilisation CategoryAC-1 conforming to IEC 60947-4-1
AC-15 conforming to IEC 60947-5-1
DC-1 conforming to IEC 60947-4-1
DC-13 conforming to IEC 60947-5-1
COMPLEMENTARY
Output Contacts2 C/O
System Requirements2 C/O
[In] Rated Current8 A
Compatibility CodeRM22
Connections - Terminalsscrew terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
screw connectors
Contacts Materialcadmium free
Control Circuit Voltage Limits- 20 % + 20 % Un
Electrical Durability100000 cycles
Housing Materialself-extinguishing plastic
Hysteresis2-2 % fixed of selectable
Immunity To Microbreaks10 ms
Insulation Resistance> 100 MOhm at 500 V DC conforming to IEC 60255-27
Maximum Measuring Cycle150 ms measurement cycle as true rms value
Maximum Switching Current8 A AC
Maximum Switching Voltage250 V AC
Measurement Error< 0.05 %/°C with temperature variation
< 1 % over the whole range with voltage variation
Mechanical Durability10000000 cycles
Minimum Switching Current10 mA at 5 V DC
Mounting Positionany position
Net Weight0.09 kg
Power Consumption In VA10-10 VA at 240 V AC 60 Hz
Repeat Accuracy+/- 0.5 % for input and measurement circuit
+/- 3 % for time delay
Reset Time1500 ms at maximum voltage
Response Time<= 300 ms
Run-up Delay At Power-up650 ms
Safety Reliability DataB10d = 350000
MTTFd = 388.1 years
Setting Accuracy Of The Switching Threshold+/- 10 % of the full scale
Setting Accuracy Of Time Delay10 P
Status LEDLED (green)power ON
LED (yellow)relay ON
Supply Frequency50...60 Hz +/- 10 %
Supply Voltage Limits160-288 V AC
Switching Capacity In VA2000 VA
Switching Threshold Drift<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Threshold Adjustment Voltage2...20 % of Un selected
Tightening Torque0.6-1 N.m conforming to IEC 60947-1
Time Delay Drift<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Voltage Detection Threshold< 100 V AC
Voltage Range200...240 V phase to phase
Width22.5 mm
ENVIRONMENT
Ambient Air Temperature For Operation-20-50 °C at 60 Hz
-20-60 °C at 50 Hz AC/DC
Ambient Air Temperature For Storage-40-70 °C
Dielectric Test Voltage2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Electromagnetic Compatibilityconducted and radiated emissions class B conforming to CISPR 22
conducted and radiated emissions class B group 1 conforming to CISPR 11
electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
emission standard for industrial environments conforming to EN/IEC 61000-6-4
emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
immunity for industrial environments conforming to EN/IEC 61000-6-2
immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
IP Degree Of ProtectionIP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Overvoltage CategoryIII conforming to IEC 60664-1
III conforming to UL 508
Pollution Degree3 conforming to IEC 60664-1
3 conforming to UL 508
Product CertificationsCCC
CE
CSA
EAC
GL
RCM
UL
Relative Humidity93-97 % at 25-55 °C conforming to IEC 60068-2-30
Shock Resistance15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
StandardsEN/IEC 60255-1
Vibration Resistance0.035 mm (f= 58.1-150 Hz) in operation conforming to IEC 60068-2-6
0.075 mm (f= 10-58.1 Hz) not in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1-150 Hz) in operation conforming to IEC 60068-2-6
1 gn (f= 10-58.1 Hz) not in operation conforming to IEC 60068-2-6
OTHER
Poles Description3-phase control relay
[Us] Rated Supply Voltage200...240 V AC
Write Your Own Review
You're reviewing:Harmony, Modular 3-phase Voltage Control Relay, 8 A, 2 CO, 200…240 V AC
Your Rating