EasyPact CVS630N Circuit Breaker, 50 KA At 415 VAC, 3P 3d, TM-D 500 A Trip Unit.

Schneider
SKU
SE_LV563315
Model
LV563315
SGD $746.36

Short description of LV563315

Molded-case circuit breakers from 16 to 630 A, with adjustable settings.
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range of product : Easypact CVS400...630
-  product or component type : Circuit breaker
-  device short name : CVS630N
-  device application : Distribution
-  poles description : 3P
-  protected poles description : 3d
-  Earth leakage protection (Vigi add on) : Without
-  [In] rated current : 630 A at 40 °C
-  breaking capacity code : N
-  network type : AC
-  [Icu] Breaking capacity  : 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-242 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
-  utilisation category : Category A
-  trip unit name : TM
- D
-  trip unit technology : Thermal
- magnetic
-  trip unit rating : 500 A at 40 °C
-  protection type : Overload protection (thermal)Short-circuit protection (magnetic)
MAIN SPECIFICATIONS
Breaking Capacity42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity CodeN
Contacts Type And Composition630 A at 40 °C
Control Typetoggle
Product Or Component Typecircuit breaker
Range Of ProductEasyPact CVS400...630
Trip Unit NameTM-D
[Ie] Rated Operational Currenttoggle
Device Short NameCVS630N
Mounting Supportbackplate
Network TypeAC
Protected Poles Description3d
RangeEasyPact
Range NameEasyPact CVS
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A
COMPLEMENTARY
Current Transformer TypeN
Interlocked Device42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Product NameEasyPact CVS
[Ics] Rated Service Breaking Capacity32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
[In] Rated Current630 A at 40 °C
Compatibility CodeCVS630
Connection Pitch45 mm
Connections - Terminalsscrew connection
Contact Position Indicatoryes
Depth110 mm
Device Applicationdistribution
Downside Connectionfront
Earth-leakage Protectionwithout
Electrical Durability4000 cycles 415 V In conforming to IEC 60947-2
Height255 mm
Instantaneous Pick-up Adjustment Range5...10 x In
Instantaneous Pick-up Adjustment Type Iiadjustable
Long Time Delay Adjustment Typefixed
Long Time Pick-up Adjustment Range0.7...1 x In
Long Time Pick-up Adjustment Type Iradjustable
Mechanical Durability15000 cycles
Mounting Modefixed
Net Weight5.2 kg
Network Frequency50/60 Hz
Protection Typeoverload protection (thermal)
short-circuit protection (magnetic)
Thermal Protection Adjustment Range350-500 A
Trip Unit Rating500-500 A at 40 °C
Upside Connectionfront
Width140 mm
[Uimp] Rated Impulse Withstand Voltage8 kV conforming to EN/IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-50-85 °C
Electrical Shock Protection Classclass II
IP Degree Of ProtectionIP40
Pollution Degree3 conforming to IEC 60664-1
Product CertificationsGOST
IEC
StandardsEN 60947-2
IEC 60947-2
OTHER
Earth Leakage CurrentTM-D
Poles Description3P
[Us] Rated Supply VoltageEasyPact CVS400...630
Write Your Own Review
You're reviewing:EasyPact CVS630N Circuit Breaker, 50 KA At 415 VAC, 3P 3d, TM-D 500 A Trip Unit.
Your Rating