residual current protection relay, Vigirex RHUs, 30 mA to 30 A, 110/130 VAC 50/60Hz, without communication, front panel mounting

Schneider
SKU
SE_LV481000
Model
LV481000
SGD $662.39

Short description of LV481000

VigiPacT RHUs is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. It can activate an alarm and a pre-alarm. The operational supply voltage is 110/130VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity is from 30mA to 30A. The time delay is adjustable from 0 to 4.5s. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor. It complies with IEC 60755, IEC 60947-2 annex M and IEC 60947-5-1 standards.
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 15 To 17 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
MAIN
RangeVigiPacT
Device Short NameRHUs
Product Or Component TypeResidual current protection relay
Relay ApplicationMonitoring relay
Protection relay
Mounting SupportFront panel
Earth-leakage Protection ClassType A
Type Of SettingKeypad
Residual Earth-leakage Sensitity Adjustment TypeAdjustable
Earth-leakage Sensitivity0.03…1 A, adjustable in step of 0.001 A
1…30 A, adjustable in step of 0.1 A
Earth-leakage Time DelayInstantaneous for 0.03 A
Adjustable 0…4.5 s for 0.03…30 A adjustable in step of 10 ms
Threshold Setting0.015...1 A adjustable in step of 0.001 A pre-alarm
1...30 A adjustable in step of 0.1 A pre-alarm
0.03...1 A adjustable in step of 0.001 A alarm
1...30 A adjustable in step of 0.1 A alarm
Current Sensors CompatibilityVigiPacT TOA earth leakage current sensor
VigiPacT A earth leakage current sensor
VigiPacT L earth leakage current sensor
[Ithe] Conventional Enclosed Thermal Current8 A
Minimum Load10 mA at 12 V
[Us] Rated Supply Voltage110...130 V AC 50/60 Hz 70...110 %
Power Consumption In VA8 VA
Monitored Distribution System1000 V - AC at 50/60 Hz (maximum)
1000 V - AC at 400 Hz (maximum)
Earthing SystemTT
TN-S
IT
[Uimp] Rated Impulse Withstand Voltage8 kV
ResetManual reset
COMPLEMENTARY
Test FunctionLocal
Remote test
Signal Contacts Composition1 C/O alarm fail-safe
1 NO pre-alarm fail-safe
Type Of MeasurementEarth fault current internal measurement, range: 20...200 %, accuracy: +/- 20 %
Refresh Time0.5 s
Tamperproof Of SettingsProtected by access code
Connections - TerminalsAlarm circuit: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12
Alarm circuit: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12
Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12
Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12
Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12
Power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Pre alarm: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12
Pre alarm: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Wire Stripping LengthAlarm circuit: 6 mm
Relay test and fault reset: 6 mm
Sensor: 6 mm
Voltage presence: 6 mm
Power supply: 6 mm
Pre alarm: 6 mm
Tightening TorqueAlarm circuit: 0.5 N.m
Relay test and fault reset: 0.5 N.m
Sensor: 0.5 N.m
Voltage presence: 0.5 N.m
Power supply: 0.5 N.m
Pre alarm: 0.5 N.m
Width72 mm
Height72 mm
Depth117 mm
Cut-out Dimensions68 x 68 mm
Net Weight0.3 kg
IP Degree Of ProtectionIP40 front face: conforming to IEC 60529
IP30 other parts: conforming to IEC 60529
IP20 connection: conforming to IEC 60529
IK Degree Of ProtectionIK07 conforming to EN 50102
Mechanical RobustnessVibrations 13.2...100 Hz: 0.7 g
Vibrations 2...13.2 Hz: +/- 1 mm
ENVIRONMENT
Environmental CharacteristicExposure to damp heat not in service conforming to IEC 60068-2-30
Exposure to damp heat in service conforming to IEC 60068-2-56
Salt mist conforming to IEC 60068-2-52
Overvoltage CategoryIV
Electrical Shock Protection ClassClass II
Electromagnetic CompatibilityConducted and radiated emissions: , B, conforming to CISPR 11
Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6
Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2
High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5
Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4
Radiated susceptibility: , 3, conforming to IEC 61000-4-3
Relative Humidity95 % at 55 °C
Pollution Degree3 conforming to IEC 60664-1
Ambient Air Temperature For Operation-25…55 °C
Ambient Air Temperature For Storage-40…85 °C