Auxiliary Contact - 2 OC Early-make - NSX100 - 250

Schneider
SKU
SE_LV429346
Model
LV429346
SGD $133.63

Short description of LV429346

2 EARLY-MAKE CONTACTS
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 To 6 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
auxiliary contact
-  2 OC early
- make
-  NSX100
-  250.
Label : Compact NSX
- range of product : NSX400...630,NSX400...630 DC,NSX100...250,NSX100...250 DC
- range : Compact
- device short name : 2 early
- make contacts
- product or component type : auxiliary contact
- device application : control
- Range Presentation : The Compact NSX molded case circuit breaker (MCCB) range is designed to optimize space and breaking capacity. The range comes in two frame sizes with a variety of optional functions and accessories.
Specifications : 
-  Flexible installation :  any position; switchboard or wall
- mounted
-  Nominal current :  16 to 630 A
-  9 Breaking capacities for the 2 sizes of circuit breakers : 
-  up to 250 A :  25, 36, 50, 70, 100, 150, 200 kA at 415 V
-  up to 630 A :  36, 50, 70, 100, 150, 200 kA at 415 V
-  both size of circuit breakers with 75 & 100 kA at 690 V
-  1, 2, 3 and 4 pole versions available
-  Large range of electronic and thermal
- magnetic protections
-  Advanced trip unit with integrated power metering :  I, U, P, E, THD, f, CosPhi
-  Interchangeable trip
- units to upgrade your panel with smarter functions
-  Plug and ready wiring system and communicating accessories
-  Wealth of options for auxiliaries and accessories (field installable)
-  Integrated earth leakage protection via Micrologic Vigi coming soon in Q4 2018 (earth leakage circuit breaker
-  ELCB)For more information, download the Compact NSX & NSXm catalog
Visit the Schneider Electric Electrical Calculation Tools to review, search and check curves, selectivity and cascading. Alternatively, download the Complimentary Technical Information catalog (PDF), which includes coordination tables.
- Range Benefits : Easy and efficient
-  Two standardized frame sizes for your convenience
-  Save space, time and effort with integrated earth leakage protection (ELCB), available in Q4 2018, in the molded case circuit breaker (MCCB) frame size
-  Easy to swap trip units and standardized accessories over time
-  Wide range of online and offline software tools that help to improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)Optimize safety
-  Highly resistant to environmental stresses
-  Roto
- active breaking technology helps to reduce early aging effects and increase operation lifespanMeasure and Communicate
-  Local and remote communication with trip alarm (earth leakage, overload, short circuit) and pre- alarms (earth leakage) allowing you to proactively increase operational and energy efficiency
-  Advanced Micrologic trip unit can assist in providing corrective, preventative and predictive maintenance and energy management to identify potential savingsWorking with communication devices, the Compact NSX inside our Smart Panels becomes an EcoStruxure connected product within our EcoStruxure Power architecture.
Click to watch the video and discover more about Compact NSX & NSXm molded case circuit breakers.
- Range Application Presentation : An excellent choice for all standard and specific applications, including : 
-  Standard applications :  industries, buildings, infrastructures
-  Specific applications demanding high performance :  marine, oil and gas extraction and processing, mining operations, metals and minerals production, and data centers
-  Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, ), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.) Ensures compliance with international standards (Find on Compact NSX certificate downloads) : 
-  IEC/EN 60947-1 and 2, IEC 60068-2-30 for type 2 tropicalisation, CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, DetNorske Veritas and RINA
MAIN SPECIFICATIONS
Product Or Component Typeauxiliary contact
Range Of ProductComPact NSX100...250
ComPact NSX100...250 DC
ComPact NSX400...630
ComPact NSX400...630 DC
[Ie] Rated Operational CurrentAC-12: 6 A at 110 V AC 50/60 Hz
AC-12: 6 A at 220/240 V AC 50/60 Hz
AC-12: 6 A at 24 V AC 50/60 Hz
AC-12: 6 A at 380/440 V AC 50/60 Hz
AC-12: 6 A at 48 V AC 50/60 Hz
AC-12: 6 A at 480 V AC 50/60 Hz
AC-12: 6 A at 660/690 V AC 50/60 Hz
AC-15: 0.1 A at 660/690 V AC 50/60 Hz
AC-15: 1.5 A at 480 V AC 50/60 Hz
AC-15: 2 A at 380/440 V AC 50/60 Hz
AC-15: 4 A at 220/240 V AC 50/60 Hz
AC-15: 5 A at 110 V AC 50/60 Hz
AC-15: 6 A at 24 V AC 50/60 Hz
AC-15: 6 A at 48 V AC 50/60 Hz
DC-12: 0.3 A at 250 V DC
DC-12: 0.6 A at 110 V DC
DC-12: 2.5 A at 48 V DC
DC-12: 6 A at 24 V DC
DC-14: 0.03 A at 250 V DC
DC-14: 0.05 A at 110 V DC
DC-14: 0.2 A at 48 V DC
DC-14: 1 A at 24 V DC
[Ue] Rated Operational VoltageAC-12: 6 A at 110 V AC 50/60 Hz
AC-12: 6 A at 220/240 V AC 50/60 Hz
AC-12: 6 A at 24 V AC 50/60 Hz
AC-12: 6 A at 380/440 V AC 50/60 Hz
AC-12: 6 A at 48 V AC 50/60 Hz
AC-12: 6 A at 480 V AC 50/60 Hz
AC-12: 6 A at 660/690 V AC 50/60 Hz
AC-15: 0.1 A at 660/690 V AC 50/60 Hz
AC-15: 1.5 A at 480 V AC 50/60 Hz
AC-15: 2 A at 380/440 V AC 50/60 Hz
AC-15: 4 A at 220/240 V AC 50/60 Hz
AC-15: 5 A at 110 V AC 50/60 Hz
AC-15: 6 A at 24 V AC 50/60 Hz
AC-15: 6 A at 48 V AC 50/60 Hz
DC-12: 0.3 A at 250 V DC
DC-12: 0.6 A at 110 V DC
DC-12: 2.5 A at 48 V DC
DC-12: 6 A at 24 V DC
DC-14: 0.03 A at 250 V DC
DC-14: 0.05 A at 110 V DC
DC-14: 0.2 A at 48 V DC
DC-14: 1 A at 24 V DC
Device Short Name2 early-make contacts
EAN133606480020445
RangeComPact
Range Compatibility ComPact NSX
ComPact NSX DC
PowerPact H
PowerPact J
PowerPact L
Range NameComPact NSX
COMPLEMENTARY
Auxiliary Contacts Operationearly-make
Auxiliary Contacts Typestandard
Device Applicationcontrol
Minimum Load100 mA at 24 V DC
Mounting Modedrawout
[Ith] Conventional Free Air Thermal Current6 A
OTHER
Poles Descriptionauxiliary contact
[Us] Rated Supply VoltageComPact NSX100...250
ComPact NSX100...250 DC
ComPact NSX400...630
ComPact NSX400...630 DC