Auxiliary Contact (spring) OF/SD - 1 NO/NC

Schneider
SKU
SE_LV426950
Model
LV426950
SGD $44.22

Short description of LV426950

AUXILIARY CONTACT OF or SD NSXm & PP-B
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 To 6 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
auxiliary contact (spring) OF/SD
-  1 NO/NC.
Label : Compact NSXm
- range : PowerPact
- device short name : SD,OF
- product or component type : auxiliary contact
- Range Presentation : The Compact NSXm molded case circuit breaker (MCCB) range comes in one size and is optimized for small spaces.
Specifications
-  New smaller frame size :  W :  81mm x H :  137mm x D :  80mm
-  Flexible installation : any position; switchboard or wall
- mounted
-  Nominal current :  16 to 160 A
-  Five breaking capacities :  16, 25, 36, 50, 70 kA at 415 V
-  3 and 4 pole versions available
-  Integrated earth leakage protection via Micrologic Vigi (Earth leakage circuit breaker
-  ELCB)
-  Thermal
- magnetic protections
-  Optimized range of auxiliaries and accessories
-  Built‑in DIN rail and plate mount capability
-  New EverLink™ connectors for bare cables​
-  Field‑installable and spring
- type auxiliaries externally visible
- Range Benefits : Easy and efficient​
-  Flexible installation for your convenience :  click into place with the built-in DIN rail, no extra parts required. Save space thanks to vertical plate mounting
-  EverLink connectors for reliable and quick bare cables connections​
-  Integrated earth leakage protection (ELCB) now available in the molded case circuit breaker (MCCB) frame size ​
-  Field
- installable accessories and one-click auxiliaries ​
-  Wide range of online and offline software tools that help to improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact)​Optimize safety ​
-  EverLink is an innovative cable connection method with patented creep
- compensating technology that is built directly into the terminal​
-  Roto
- active breaking technology to reduces the risk of short circuiting by a factor of eight, to extend the life of your installation ​Clear communication​
-  Scan QR code for easy access to information about the product and quick access to the customer care center​
-  Auxiliaries externally visible through flags and its windowCompact NSXm installed inside our Smart Panels becomes a connectable product within our EcoStruxure Power architecture
Click to watch the video and discover more about Compact NSX & NSXm molded case circuit breakers.
- Range Application Presentation : An excellent choice for all standard applications, including :  ​
-  Standard applications in industry, building and infrastructure​
-  Low‑voltage switchboards (as feeder in drawers) for power control centers​
-  Low‑voltage panelboards (as incomer) or sub
- panelboards(as feeder) for electrical distribution in small, medium, and commercial buildings​
-  Machines (as incomer) — HVAC, packaging, lifting, pumping, conveying​
-  Control panels — Water treatment, tunnel, in automation solutions​ Ensures compliance with international standards (Find on Compact NSXm certificate downloads) :  ​
-  IEC/EN 60947-1 and
- 2, IEC 60068-2-30 for type 2 tropicalisation, CCC, EAC and other local certifications​
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, DetNorske Veritas and RINA
MAIN SPECIFICATIONS
Product Or Component Typeauxiliary contact
Range Of ProductComPact NSXm
[Ie] Rated Operational CurrentAC-12: 5 A at 110...127 V AC 50/60 Hz
AC-12: 5 A at 220/240 V AC 50/60 Hz
AC-12: 5 A at 24 V AC 50/60 Hz
AC-12: 5 A at 380/440 V AC 50/60 Hz
AC-12: 5 A at 48 V AC 50/60 Hz
AC-12: 5 A at 660/690 V AC 50/60 Hz
AC-15: 0.1 A at 660/690 V AC 50/60 Hz
AC-15: 2.5 A at 380/440 V AC 50/60 Hz
AC-15: 3 A at 220/240 V AC 50/60 Hz
AC-15: 4 A at 110...127 V AC 50/60 Hz
AC-15: 5 A at 24 V AC 50/60 Hz
AC-15: 5 A at 48 V AC 50/60 Hz
DC-12: 0.3 A at 250 V DC
DC-12: 0.6 A at 110 V DC
DC-12: 2.5 A at 48 V DC
DC-12: 5 A at 24 V DC
DC-13: 0.05 A at 250 V DC
DC-13: 0.35 A at 110 V DC
DC-13: 1.2 A at 48 V DC
DC-13: 2.5 A at 24 V DC
DC-14: 0.03 A at 250 V DC
DC-14: 0.05 A at 110 V DC
DC-14: 0.2 A at 48 V DC
DC-14: 1 A at 24 V DC
[Ue] Rated Operational VoltageAC-12: 5 A at 110...127 V AC 50/60 Hz
AC-12: 5 A at 220/240 V AC 50/60 Hz
AC-12: 5 A at 24 V AC 50/60 Hz
AC-12: 5 A at 380/440 V AC 50/60 Hz
AC-12: 5 A at 48 V AC 50/60 Hz
AC-12: 5 A at 660/690 V AC 50/60 Hz
AC-15: 0.1 A at 660/690 V AC 50/60 Hz
AC-15: 2.5 A at 380/440 V AC 50/60 Hz
AC-15: 3 A at 220/240 V AC 50/60 Hz
AC-15: 4 A at 110...127 V AC 50/60 Hz
AC-15: 5 A at 24 V AC 50/60 Hz
AC-15: 5 A at 48 V AC 50/60 Hz
DC-12: 0.3 A at 250 V DC
DC-12: 0.6 A at 110 V DC
DC-12: 2.5 A at 48 V DC
DC-12: 5 A at 24 V DC
DC-13: 0.05 A at 250 V DC
DC-13: 0.35 A at 110 V DC
DC-13: 1.2 A at 48 V DC
DC-13: 2.5 A at 24 V DC
DC-14: 0.03 A at 250 V DC
DC-14: 0.05 A at 110 V DC
DC-14: 0.2 A at 48 V DC
DC-14: 1 A at 24 V DC
Device Short NameOF
SD
EAN133606485444215
Rangecompact
Range Compatibility ComPact NSXm
PowerPact B
Range NameCompact NSXm
Signal Contacts Composition1 NO/NC
COMPLEMENTARY
Auxiliary Connection Terminalspring
Auxiliary Contacts Typestandard
Device Applicationbreaker status monitoring
Fault Typeoverload
short-circuit
Local SignallingON/OFF indication for open/close
trip indicator for relay trip indicator
Minimum Load2 mA at 17 V DC
Mounting Modeclip-on
Wire Stripping Length8 mm for front connection
[Ith] Conventional Free Air Thermal Current5 A
OTHER
Poles Descriptionauxiliary contact
[Us] Rated Supply VoltageComPact NSXm