Advanced Control Unit, TeSys U, 1.25-5A, 3P Motors, Protection & Diagnostic, Class 10, Coil 48-72V AC/DC.

Schneider
SKU
SE_LUCB05ES
Model
LUCB05ES
SGD $156.15

Short description of LUCB05ES

All-in-one motor starters up to 38 A (18.5 kW / 400 V)
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : TeSys
-  range of product : TeSys U
-  product name : TeSys U
-  device short name : LUCB
-  product or component type : Advanced control unit
-  device application : Motor controlMotor protection
-  product specific application : Basic protection and advanced functions, communication
-  main function available : Earth fault protectionManual resetProtection against phase failure and phase imbalanceProtection against overload and short-circuit
-  product compatibility : Power base LUB12Power base LUB32Power base LUB38Power base LUB120Power base LUB320Power base LUB380Reversing contactor breaker LU2B12ESReversing contactor breaker LU2B32ES
-  [Ue] rated operational voltage : 690 V AC
-  network frequency : 40...60 Hz
-  load type : 3-phase motor
-  cooling :  self-cooled
-  utilisation category : AC
- 43AC
- 41AC
- 44
-  motor power kW : 1.5 kW at 400...440 V AC 50/60 Hz2.2 kW at 500 V AC 50/60 Hz3 kW at 690 V AC 50/60 Hz
-  rated motor current adjustment range : 1.25…5 A
-  thermal overload class : Class 10
-  frequency limit :  40…60 Hz
-  temperature compensation- 25…70 °C conforming to IEC 60947-6-2Class 10
-  frequency limit :  40…60 Hz
-  temperature compensation- 25…70 °C conforming to UL 508
-  tripping threshold : 14.2 x Ir +/- 20 %
-  phase failure sensitivity : Yes
-  [Uc] control circuit voltage : 48 V AC48...72 V DC
MAIN SPECIFICATIONS
Product Or Component Typeadvanced control unit
Range Of ProductTeSys U
[Uc] Control Circuit Voltage48 V AC
48...72 V DC
[Ue] Rated Operational Voltage690 V AC
Device Short NameLUCB
Function Availableearth fault protection
manual reset
protection against overload and short-circuit
protection against phase failure and phase imbalance
Product Specific Applicationbasic protection and advanced functions, communication
RangeTeSys
Range NameTeSys U
Thermal Overload Classclass 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to IEC 60947-6-2
class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-70 °C conforming to UL 508
Utilisation CategoryAC-41
AC-43
AC-44
COMPLEMENTARY
Communication Network Type690 V AC
Product NameTeSys U
Compatibility CodeLUCB
Control Circuit Voltage Limits29 V for AC circuit 48 V drop-out
29 V for DC circuit 48...72 V drop-out
38.5...72 V for AC circuit 48 V in operation
38.5...93 V for DC circuit 48...72 V in operation
Depth60 mm
Device Applicationmotor control
motor protection
Fixing Modeplug-in (front face)
Height66 mm
Immunity To Microbreaks3 ms
Load Type3-phase motor - cooling: self-cooled
Motor Power KW1.5 kW at 400...440 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
3 kW at 690 V AC 50/60 Hz
Network Frequency40...60 Hz
Operating Time35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
35 ms opening with LUB38 for control circuit
60 ms closing with LUB12 for control circuit
60 ms closing with LUB32 for control circuit
60 ms closing with LUB38 for control circuit
Phase Failure Sensitivityyes
Product Compatibilitypower base LUB12
power base LUB120
power base LUB32
power base LUB320
power base LUB38
power base LUB380
reversing contactor breaker LU2B12ES
reversing contactor breaker LU2B32ES
Resetmanual reset
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Thermal Protection Adjustment Range1.25-5 A
Tripping Threshold14.2 x Ir +/- 20 %
Typical Current Consumption280 mA at 48 V AC I maximum while closing with LUB12
280 mA at 48 V AC I maximum while closing with LUB32
280 mA at 48 V AC I maximum while closing with LUB38
280 mA at 48...72 V DC I maximum while closing with LUB12
280 mA at 48...72 V DC I maximum while closing with LUB32
280 mA at 48...72 V DC I maximum while closing with LUB38
35 mA at 48 V AC I rms sealed with LUB12
35 mA at 48...72 V DC I rms sealed with LUB12
45 mA at 48 V AC I rms sealed with LUB32
45 mA at 48 V AC I rms sealed with LUB38
45 mA at 48...72 V DC I rms sealed with LUB32
45 mA at 48...72 V DC I rms sealed with LUB38
Width45 mm
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
[Ui] Rated Insulation Voltage600 V conforming to CSA C22.2 No 60947-4-1
600 V conforming to UL 60947-4-1
690 V conforming to IEC 60947-6-2
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
Fire Resistance650 °C conforming to IEC 60695-2-12
960 °C parts supporting live components conforming to IEC 60695-2-12
Heat Dissipation2-2 W for control circuit with LUB12
3-3 W for control circuit with LUB32
3-3 W for control circuit with LUB38
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Immunity To Voltage Dips70 % / 500 ms conforming to IEC 61000-4-11
IP Degree Of ProtectionIP20 front panel and wired terminals conforming to IEC 60947-1
IP20 other faces conforming to IEC 60947-1
IP40 front panel outside connection zone conforming to IEC 60947-1
Non-dissipating Shock Wave1 kV serial mode conforming to IEC 60947-6-2
2 kV common mode conforming to IEC 60947-6-2
Operating Altitude2000 m
Product CertificationsASEFA
ATEX
CCC
CE
CSA
EAC
Marine
UL
Protective TreatmentTH conforming to IEC 60068
Resistance To Electrostatic Discharge8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance To Radiated Fields10 V/m 3 conforming to IEC 61000-4-3
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
StandardsCSA C22.2 No 60947-4-1, with phase barrier
EN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
Vibration Resistance2 gn, 5-300 Hz, power poles open conforming to IEC 60068-2-6
4 gn, 5-300 Hz, power poles closed conforming to IEC 60068-2-6
OTHER
Poles Descriptionadvanced control unit
[Us] Rated Supply VoltageTeSys U