Motor Management, TeSys T, Motor Controller, Ethernet/IP, Modbus/TCP, 6 Inputs, 3 Outputs, 1.35 To 27A, 100 To 240 VAC

Schneider
SKU
SE_LTMR27EFM
Model
LTMR27EFM
SGD $1,639.01

Short description of LTMR27EFM

CONTROLLER ETERNET 1,35 27A 115 230VAC
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 9 To 11 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
motor controller LTMR TeSys T
-  100..240 V AC 27 A for Ethernet TCP/IP.
Label :  Tesys T
-  range :  TeSys
-  communication port protocol :  Modbus TCP/EtherNet/IP
-  bus type :  Ethernet IEEE 802.3 0...159, transmission rate :  10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
-  product name :  TeSys T
-  device short name :  LTMR
-  product or component type :  motor controller
-  device application :  equipment monitoring and control
-  measurement current :  1.35-27 A
-  [Us] rated supply voltage :  100...240 V AC 50/60 Hz
-  current consumption :  8...62.8 mA
-  supply voltage limits :  93.5-264 V AC
-  Range Presentation :  TeSys T is an advanced motor management and protection system designed to prevent malfunctions. Both motor and mechanics are protected, so unexpected process or production halts can be anticipated.
TeSys T comprises : 
-  A controller providing main protection and control functions
-  An extension module that completes the functions of the controller by providing voltage and power protection and monitoring
-  An LTMCU operator control unit for reading, diagnostics and modification of the parameters monitored SoMove configuration software, enables simple and user-friendly setup of motor starters incorporated with TeSys T.
Fully open, it communicates with commonly used Ethernet networks and protocols :  Modbus/TCP and EtherNet/IP, and can also communicate via Modbus, CANopen, DeviceNet, PROFIBUS DP protocols.

-  Range Benefits :  Give your motor starters a sixth sense!
-  TeSys T incorporates a communication interface for remote supervision and control of the motor.
-  Open to all communication protocols, TeSys T can efficiently replace all existing relays.
-  Range Application Presentation :  Industrial installations such as : 
-  Oil & gas
-  Mining and mineral
-  Water treatment
-  Metallurgy
-  Pulp & paper
-  Pharmaceutical Integration in intelligent Motor Control centre applications for : 
-  Pumping, ventilation, filtering
-  Compressors, mixers, crushers, conveyor systems
MAIN SPECIFICATIONS
Analogue Input Number100...240 V AC 50/60 Hz
Contacts Type And Composition1 NO + 1 NC fault signal
3 NO
Discrete Input Number1 NO + 1 NC fault signal
3 NO
Measurement Accuracy+/- 30 min/year internal clock
0,02 temperature
1 % current
1 % voltage (100...830 V)
3 % power factor
5 % active and reactive power
5 % earth fault current external measurement
5...15 % earth fault current internal measurement
Product Or Component Typemotor controller
Communication Port ProtocolModbus TCP/EtherNet/IP
Device Short NameLTMR
EAN133389119404891
RangeTeSys
Range NameTeSys T
COMPLEMENTARY
Product NameTeSys T
Time Delay+/- 30 min/year internal clock
0,02 temperature
1 % current
1 % voltage (100...830 V)
3 % power factor
5 % active and reactive power
5 % earth fault current external measurement
5...15 % earth fault current internal measurement
Associated Fuse Rating0.5 A gG for control circuit
4 A gG for output
Bus TypeEthernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
Compatibility CodeLTMR
Connection Pitch5.08 mm
Connections - Terminalscontrol circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) flexible without cable end
control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) solid without cable end
control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible with cable end
control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible without cable end
control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) flexible with cable end
control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) solid without cable end
control circuit: connector 2 cable(s) 0.2-1.5 mm² (AWG 24...AWG 14) flexible without cable end
control circuit: connector 2 cable(s) 0.5-1.5 mm² (AWG 24...AWG 14) flexible without cable end
Current Consumption8...62.8 mA
Current State 0 Guaranteedlogic input: 0...40 V and <= 15 mA for 25 ms
Current State 1 Guaranteedlogic input: 79...264 V and >= 2 mA for 25 ms
Depth122.5 mm
Device Applicationequipment monitoring and control
Height61 mm
Input Current3.1 mA at 100 V
7.5 mA at 240 V
Load Current5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
Logic Input Number6
Maximum Operating Frequency2 Hz
Maximum Operating Rate1800 cyc/h
Measurement Current1.35-27 A
Mechanical Robustnessshocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Metering Typeaverage current Iavg
earth-fault current
imbalance current
phase current I1, I2, I3 RMS
temperature
Net Weight0.53 kg
Network And Machine Diagnosis Typeevent recording
fault recording
motor control command recording
phase fault and earth fault trip counters
remaining operating time before overload tripping
running hours counter/operating time
starting current and time
trip context information
trip history information
waiting time after overload tripping
Permissible Power30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
Protection Typeearth-leakage protection
load fluctuation
locked rotor
overload
overload (long time)
phase failure
phase unbalance
power factor variation
reverse polarity protection
thermal overload protection
thermal protection
Short-circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Supply Voltage Limits93.5-264 V AC
Tightening Torquecontrol circuit: 0.5-0.6 N.m flat screwdriver 3 mm
Web Servicesweb server
Width91 mm
[Uimp] Rated Impulse Withstand Voltage0.8 kV communication circuit conforming to EN/IEC 60947-4-1
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
[Ui] Rated Insulation Voltage690 V conforming to CSA C22.2 No 14
690 V conforming to EN/IEC 60947-1
690 V conforming to UL 508
ENVIRONMENT
Ambient Air Temperature For Operation-20-60 °C
Ambient Air Temperature For Storage-40-80 °C
Electromagnetic Compatibilitycommunication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Fire Resistance650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
IP Degree Of ProtectionIP20
Operating Altitude<= 2000 m without derating
Overvoltage CategoryIII
Pollution Degree3
Product CertificationsABS
ATEX
BV
CCC
CSA
C-Tick
DNV
EAC
GL
KERI
LROS (Lloyds register of shipping)
NOM
RINA
RMRoS
UL
Protective Treatment12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
StandardsCSA C22.2 No 14
EN 60947-4-1
IACS E10
IEC 60947-4-1
UL 508
OTHER
Poles Descriptionmotor controller
[Us] Rated Supply Voltage100...240 V AC 50/60 Hz